Audio-Technica p51857_1800 manual Single-channel Operation

Page 9

9

3.To “back out” of the Manual Frequency Set mode without making a frequency choice, simply press the Set button once to exit the menu and return the receiver to normal operation. The word “ESCAPE” will appear in the window, and no changes in frequency setting will be made; the receiver's audio output will again be enabled (when Dual-channel Control Switch is returned to Hold position).

To set frequency for Receiver Channel 2, switch Dual-channel Control Switch to 2 (right position).

Repeat steps 1-2 above.

To lock settings and operate unit, switch Dual-channel Control Switch to Hold (center position).

Note: While Channel Selection mode is still active, if the Dual-channel Control Switch is moved back to Hold position before channel selection is complete, LED will remain red and audio will remain muted until the control sequence is completed.

First…

Turn the power on by moving the Power Switch to Both (for dual-channel operation). Then switch Dual-channel Control Switch to 1 (left position).

1.Press the Set button to enter the Frequency Selection Menu mode; the word “MENU” will appear.

2.Use the Up or Down arrow to reach Scan 1, Scan 2, or Scan 3. Press the Set button once to select one of these three Scan groups. The word “SCAN1”, “SCAN2” or “SCAN3” will flash in the LCD window.

3.Press the Up or Down arrow to begin the scan. Press the Up arrow to scan up from the lowest frequency in the group; press the Down arrow to scan down from the highest frequency in the group.

4.The first available frequency will flash in the LCD window. To activate this frequency selection, press and hold the Set button until the word “STORED” appears in the LCD window.

5.If you do not wish to use the frequency found, you may press the Up or Down arrow. The Up arrow will scan upwards, the Down arrow will scan downwards, from the frequency you are on.

6.To set frequency for Receiver Channel 2 (for dual-channel operation), switch Dual-channel Control Switch to 2 (right position). Repeat steps 1- 4 above. Note: Be certain to select the same Scan Group that you used for Receiver Channel 1.

7.To lock settings and operate unit in dual-channel operation (using two transmitters), switch Dual-channel Control Switch to Hold (center position). The receiver will return to normal operation, audio function will be restored and the Dual-channel Control LED indictor will turn green.

8.If you are using multiple systems, use the same scan group for all receivers. After completing the first receiver’s scan and frequency selections, set its transmitters to the appropriate frequencies (see How to Set Frequencies on your Transmitter, page 12 ); leave the transmitters On, and run the next receiver’s automatic scan function. Always set a receiver-transmitter pair to the same frequency before using the automatic scan function to select frequencies for the next receiver.

In the event that no more free frequencies are available within the scan group, the receiver will indicate “END” on the receiver display. In this case, select a different scan group for both Receiver Channels 1 and 2 and re-scan.

Using the Automatic Scan Function to Set Receiver Frequency (dual-channel operation)

Note: While Channel Selection mode is still active, if the Dual-channel Control Switch is moved back to Hold position before channel selection is complete, LED will remain red and audio will remain muted until the control sequence is completed.

First…

Single-channel Operation

Turn the power on by moving the Power Switch to the 1 position (for single-channel operation). (using one transmitter)

Switch Dual-channel Control Switch to 1 (left position). Output from Receiver Channel 1 is now

Setting Receiver Frequency Manually

muted. Note: Output B is not active when the Power Switch is in the “1” position.

 

1.Press Set button. The word “MENU” will appear. Press Up arrow to show current frequency. Press Set button and frequency will begin to flash; use up and down arrows to adjust the frequency. Frequency changes in 25 kHz steps. To increase scroll speed, hold the up or down arrow for more than 4 seconds.

2.When you arrive at desired frequency, press and hold the Set button until the word “STORED” appears. Frequency (which appears on the screen) is now set.

3.To “back out” of the Manual Frequency Set mode without making a frequency choice, simply press the Set button once to exit the menu and return the receiver to normal operation. The word “ESCAPE” will appear in the window, and no changes in frequency setting will be made; the receiver's audio output will again be enabled.

To lock settings, un-mute and operate the unit, switch Dual-channel Control Switch to Hold (center position).

Image 9
Contents Series About RF Interference ContentsSeries Components dual-channel Receiver and Included Components/AccessoriesSystem Features dual-channel If your system is equipped with a Plug-on Transmitter Quick Overview of System OperationATW-R1820 Dual-channel Receiver Controls front panel Output Select Switch Output aOutput B Operating the Receiver ATW-R1820 Dual-channel Receiver BatteriesSelecting Frequencies Overview… Dual-channel Operation First…Single-channel Operation Switch is in the 1 position Power/Mute Button Power-on LEDBattery Door AntennaTransmitter Batteries Battery ConditionOperating the Transmitter ATW-T1801 ATW-T1802Transmitter Functions Setting DescriptionReceiver Accessories Available AccessoriesTransmitter Accessories Tips for Best ResultsSpecifications† Overall SystemATW-T1802 Plug-on Transmitter One-Year Limited Warranty

p51857_1800 specifications

The Audio-Technica P51857_1800 is a versatile and high-performance microphone designed to meet the needs of performers and sound engineers alike. Part of Audio-Technica's acclaimed lineup, this model stands out for its exceptional sound quality and robust build, making it a top choice for live performances, studio recordings, and broadcasting applications.

One of the main features of the P51857_1800 is its dynamic microphone design. This construction affords the microphone superior durability, allowing it to withstand the rigors of live performances. Dynamic microphones are renowned for their ability to handle high sound pressure levels without distortion, making the P51857_1800 particularly well-suited for loud environments, such as concerts and public speaking events.

The P51857_1800 utilizes a cardioid pickup pattern, which is essential for focusing on the sound source directly in front of the microphone while minimizing background noise from the sides and rear. This feature ensures that the microphone captures vocals and instruments with clarity and precision, making it an excellent choice for vocalists and instrumentalists alike. The cardioid pattern also helps in reducing feedback during live performances.

In terms of technology, the Audio-Technica P51857_1800 is equipped with a frequency response range that enhances its performance across various sound frequencies. This broad frequency response allows for accurate reproduction of audio, whether it's the subtle nuances of a vocalist's voice or the dynamic range of a musical instrument. The microphone's ability to maintain fidelity at both low and high frequencies is a testament to its advanced engineering.

Additionally, the P51857_1800 features a rugged steel construction that provides not only durability but also a degree of resistance to mechanical wear and tear. The microphone's design incorporates a protective grille that shields the internal components from plosives and moisture, ensuring that the microphone remains functional even in challenging conditions.

Moreover, this model is lightweight and easy to handle, making it convenient for on-stage use. Its compatibility with standard microphone stands and easy-to-use connectivity options allow for quick setup and adjustments during performances.

In summary, the Audio-Technica P51857_1800 is a dynamic microphone that offers a blend of high sound quality, durability, and advanced technology. Featuring a cardioid pickup pattern, a broad frequency response range, and a robust design, it serves as an ideal tool for artists and sound engineers looking to achieve professional-quality audio in live and studio settings. Whether it’s for vocals, instruments, or broadcasting, the P51857_1800 delivers performance that can be relied upon in any scenario.