Hoover Vacuum Systems owner manual If you have a p ro b l e m, Headlight re p l a c e N t

Page 9

4 - 17

E

Replace brush roll cover (E) over agitator b rush roll. Replace 3 short scre w s .

4 - 18

Position hood on top of nozzle base.

Tu rn nozzle over. Replace 2 short scre w s at the back of nozzle and 2 long scre w s at the fro n t .

Agitator brushes and

brush roll re p l a c e m e n t

When to replace brushes

With CORDED hose,disconnect hose p ower cord from electrical outlet. W i t h CORDLESS hose,disconnect end of hose from electrified inlet va l v e.

4 - 19

When brush roll brushes are worn, the b rush roll should be re p l a c e d .

To check condition of brushes, move edge of a card across bottom plate while t u rning brush roll. To maintain cleaning

e ffectiveness, replace brush roll if bru s h e s do not touch card .

What to buy

When purchasing a new agitator bru s h roll, ask for HOOVER p a rt no.48414-071.

How to replace

With CORDED hose,disconnect hose p ower cord from electrical outlet. W i t h CORDLESS hose,disconnect end of hose from electrified inlet va l v e.

1. Remove hood, duct cover, belt and

b rush roll as shown in Figs. 4-10 to 4-15.

2.Discard old brush ro l l .

3.Replace new brush roll and belt as shown in Figs. 4-16 to 4-18.

Headlight re p l a c e-

m e n t

The headlight, located on top of the power nozzle, operates when the clean- er is turned on. Use only HOOVER part no. 27317-307, which is a fused bulb, when replacing the headlight.

4 - 20

How to replace

Disconnect cleaner from electrical outlet and disconnect power nozzle from extension wands.

1.Remove the hood as shown in Figs. 4-10 and 4-11.

2.Push old bulb into socket and twist to remove. Push new bulb into socket and twist into place.

3.Replace hood.

Edge groomer

replacement

When to replace

The edge groomers, located on both sides of the nozzle, should be re p l a c e d when they no longer extend past the sur- face of the bottom plate.

4 - 21

J

I

What to buy

When purchasing edge groomers, ask for Hoover p a rt no.39511004.

How to replace

Disconnect cleaner from electrical outlet.

1.Remove hood and b rush ro l l cover as shown in Figs. 4-10 to 4-13.

2.Pull off both old edge groomers (I).

3.Push each new groomer onto the 3 tabs (J), starting with one of the end tabs. Then push the groomer onto the middle and remaining end tab.

4.Replace brush roll cover and hood as shown in Figs. 4-17 and 4-18.

5.If you have a p ro b l e m

If a minor problem occurs, it usually can be solved quite easily when the cause is found by using the check list below.

Problem: Agitator brush roll

won’t run

Possible cause

Possible solution

Hose power cord, nozzle power cord or cordless hose, not firmly plugged in.

Plug firmly into receptacle.

Broken or worn belt.

Replace belt.

Floor surface set to “BARE” in wrong position.

Set floor surface to “RUG” posi- tion.

Continued 9

Image 9
Contents English pp D e Nozzle Descriptions UnpackingrAssemblingr Attach corded hose to Wall inlet valveAttach cordless hose To electrified wall inlet L v e Hand grip contro l s How to useMaintenance Power nozzlesA n d a rd PowerMAX power Z z l e s Disconnect hose power cord from elec- trical outlet How to to re p l a c ePowerMAX power nozzle only Agitator brush ro l l Re p l a c e m e n tWhen to replace N d Tunnel power Z z l eMust be visible End plate H until it slides into placeEdge groomer Replacement If you have a p ro b l e mHeadlight re p l a c e N t Low suction Limited WarrantyBlockage in system Agitator brush roll not runningFull five year warranty on all parts and labour Months from date of purchaseANY Street

Vacuum Systems specifications

Hoover vacuum systems have established themselves as a trustworthy choice for maintaining cleanliness in homes and commercial spaces. With a rich history dating back to the early 20th century, Hoover has consistently demonstrated innovation in design and functionality.

One of the standout features of Hoover vacuum systems is their powerful suction capabilities. Utilizing advanced motor technology, these vacuums are engineered to deliver superior cleaning performance on various floor types, including carpets, hardwoods, and tile. This capability is complemented by adjustable suction settings that allow users to tailor the vacuum's performance based on the surface being cleaned.

HEPA filtration is another hallmark of Hoover systems. Many models incorporate high-efficiency particulate air filters, which trap 99.97% of dust, pollen, and pet dander, making them ideal for allergy sufferers. This technology not only enhances air quality but also ensures that the vacuum retains dirt and allergens effectively, providing a cleaner environment.

Hoover also prides itself on the ease of use and ergonomic design of its vacuums. Features like lightweight construction, swivel steering, and easy-to-control handles contribute to reduced user fatigue during cleaning sessions. Many models come equipped with large, easy-to-empty dust bins, which simplify maintenance and enhance convenience.

Technological advancements have led to the integration of smart features in newer Hoover models. For instance, some vacuum systems now offer app connectivity that allows users to schedule cleanings, monitor performance, and receive maintenance reminders. Moreover, the introduction of robotic vacuum systems reflects Hoover’s commitment to innovation, enabling automated cleaning solutions for busy households.

Durability is another significant characteristic of Hoover products. Designed to withstand rigorous use, these vacuum systems are built with high-quality materials and components, ensuring longevity.

In summary, Hoover vacuum systems encompass powerful suction, advanced filtration technologies, user-centric designs, and innovative features, making them an excellent choice for users seeking effective cleaning solutions. Whether for everyday household use or larger commercial applications, Hoover continues to embody quality and reliability in the world of cleaning appliances.