Wand and Hose Assembly
To attach power nozzle, slide end of wand into elbow on nozzle (Fig. E). Plug cord on power nozzle into connector in sheath (Fig. F). To disassemble unplug cord, press release button and pull wand out.
CAUTION: Turn appliance off before connecting or disconnecting power nozzle.
Fig. E
Fig. F
Information Panel
For normal running only the Green Power Symbol Is Illuminated.
Overheating Protection - | Bag Check - Should you |
See below. | attempt to operate cleaner |
| without a filter bag, the unit |
| will not start, and the bag |
| check symbol will appear. |
| Simply open the front cover |
| and insert a new filter bag; the |
| unit will then start. |
Power - When not | Bag Change - Symbol will |
illuminated, check | illuminate and cleaner will |
power source. | shut off. Replace filter bag, |
| reset ON/OFF switch. |
Overheating Protection
The motor of this cleaner shuts off when the cleaner temperature rises above proper operating temperature. This prevents damage from overheating, and prolongs cleaning power.
•If the cleaner shuts off, turn cleaner OFF and disconnect power cord.
•Check the wand, hose and power nozzle for blockage.
•With the power cord disconnected from outlet, allow the machine to cool for approximately 30 minutes before using again.
•After cleaner returns to proper temperature, plug cord in, turn cleaner on, and resume cleaning.
5