Electrical Connections continued.

!CAUTION: The presence of water in the piping and water heater does not provide sufficient conduction for a ground. Non-metallic piping, dielectric unions, flexible connectors etc. can cause the water heater to be electrically isolated.

A separate branch circuit with copper conductors, over current protective device and suitable disconnecting means must be provided by a qualified electrician.

All wiring must conform to local codes or latest edition of National Electrical Code ANSI/NFPA 70.

The water heater is completely wired to the Electrical Power Hookup Terminals inside the jacket at the top front of the water heater. An opening for 1/2″ or 3/4″ electrical fitting is provided for field wiring connections.

The voltage requirements and wattage load for the water heater are specified on the rating plate on the front of the water heater.

The branch circuit wiring should include either:

Metallic conduit or metallic sheathed cable approved for use as a grounding conductor and installed with fittings approved for the purpose.

Non-metallic sheathed cable, metallic conduit or metallic sheathed cable not approved for use as a ground conductor shall include a separate conductor for grounding. It should be attached to the ground terminals of the water heater and the electrical distribution box.

240V 1PH

21.5 Max. AMP draw

10 gauge wire

Minimum 30 AMP circuit

!WARNING: If local codes require external application of insulation blanket kits the manufacturer’s instructions included with the kit must be carefully followed.

Insulation Blankets

Insulation blankets, available to the general public, for external use on electric water heaters are not necessary. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters. This water heater meets or exceeds the National Appliance Energy Conservation Act standards with respect to insulation and standby loss requirements making an insulation blanket unnecessary.

The manufacturer’s warranty does not cover any damage or defect caused by installation, attachment or use of any type of energy saving or other unapproved devices (other than those authorized by the manufacturer) into, onto or in conjunction with the water heater. The use of unauthorized energy saving devices may shorten the life of the water heater and may endanger life and property.

The manufacturer disclaims any responsibility for such loss or injury resulting from the use of such unauthorized devices.

!CAUTION: If local codes require the application of an external insulation blanket to this water heater, pay careful attention to the following so as not to restrict the proper function and operation of the water heater:

Do not cover the operating or warning labels attached to the water heater or attempt to relocate them on the exterior of insulation blanket.

Do not apply insulation to the top of the heat pump.

Filter

Top of Heat Pump

Coils

Do not cover the coils around the sides of the heat pump.

Do not cover the access door to temperature control, temperature and pressure relief valve or drain valve.

Inspect the insulation blanket

frequently.9

Image 9
Contents 92-103234-02 Water HeatersFor Your Records Time/Temperature Relationship in Scalds Water temperature settingFor Installations in the State of California Local Installation Regulations Installing the water heaterLocation Inspect ShipmentThermal Expansion Water Supply ConnectionsCondensate Drains for the Heat Pump Relief Valve Typical InstallationElectrical Connections To Fill the Water HeaterInsulation Blankets Hot and Cold Pipe Insulation Installation Relief and DrainValve Insulation InstallationWiring Installation ChecklistWater Heater Location Water SupplySafety Controls Water Temperature SettingOperating the water heater Temperature Settings Basic Water Heater OperationElectric Heat Only Care and cleaning of the water heater Routine Preventative MaintenanceDraining the Water Heater Anode Rod Vacation and Extended Shut-DownProblem Possible Causes What to Do Before You Call For Service…Instructions For Placing a Parts Order Replacement PartsCavity Insert Instructions Wiring Diagram If YOU Need Service

HP50RH, HP50RU, 92-103234-02, HP40RU, AP15121-1 specifications

The Rheem AP15121-1, HP40RU, 92-103234-02, HP50RU, and HP50RH are central components in Rheem's commitment to providing high-quality water heating solutions. These models represent some of the company’s efficient and technologically advanced offerings designed to meet diverse residential and commercial water heating needs.

One of the standout features of these models is their high energy efficiency, which is critical for reducing operational costs and environmental impact. Many of these units are equipped with advanced energy-saving technologies that comply with stringent energy regulations, ensuring they operate effectively while minimizing energy consumption. For instance, some models have been certified with Energy Star ratings, which guarantees they meet high-energy efficiency standards.

The Rheem HP40RU and HP50RU units are particularly noted for their robust performance, offering capacities of 40 and 50 gallons, respectively. This makes them suitable for households with varying hot water demands, from small families to larger households. The design of these tanks allows for efficient heat retention, which means less energy is required to maintain the desired water temperature.

Additionally, the Rheem AP15121-1 offers technology that integrates smart features, such as Wi-Fi connectivity, enabling users to monitor and manage water heating systems through mobile applications. This feature enhances convenience and provides insights into usage patterns, allowing for better energy management.

In terms of safety and durability, these Rheem models are designed with advanced safety mechanisms, including automatic shut-off features and high-quality materials to prevent leaks and corrosion, prolonging the unit's lifespan. The 92-103234-02 model incorporates a professional-grade design focused on long-term reliability, which is essential for commercial environments.

Another significant characteristic of these models is their user-friendly interfaces and straightforward installation processes, which can minimize installation times and simplify maintenance. Many units come with comprehensive warranties, reflecting Rheem's confidence in their products and providing peace of mind for consumers.

Overall, the Rheem AP15121-1, HP40RU, 92-103234-02, HP50RU, and HP50RH bring a blend of efficiency, reliability, and innovative technology, making them ideal choices for anyone in the market for a durable and effective water heating solution. Whether for residential or commercial needs, these models uphold Rheem's esteemed reputation in the water heating industry.