Desa CVDR18, CPVSR18, CVDR24, CVSR18, CVSR24, CPVSR24, and CVDR30 Operating Appliance

Page 12

RADCO BURNERS FOR VENTED NATURAL GAS LOGS

OPERATING

APPLIANCE

FOR YOUR SAFETY

READ BEFORE

LIGHTING

WARNING: Keep flue open when operating unit.

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information, above.

2.Turn the gas shut-off valve to OFF.

3.Wait five (5) minutes to clear out any gas. If you then smell gas STOP! Fol- low the safety information above. If you don't smell gas, go on to the next step.

4.Light a match and lay it on top of the pan material about 2" from the end of the supply side of the pan

5.Slowly turn the gas shut-off valve ON until the burner ignites. If the burner doesn’t ignite within 10 seconds with the match burning, turn the shut-off valve OFF and repeat steps 1 through 4 again.

GAS SHUT-OFF

VALVE OPERATION

Flame Adjustment

1.Adjust the flame ON/OFF by turn-

ing the gas shut-off valve counter-

clockwise to open or clock-

wise to close, as necessary.

Shutting Off Appliance

1.Turn gas shut-off valve clockwise to the OFF position.

CURING LOGS

During the 2-3 hour appliance break-in period, you may detect an odor from the appliance as the various paints and com- pounds used in the manufacturing of this log set cure. This is a normal and tempo- rary situation that is not cause for alarm. However, you may want to provide extra ventilation to the room during this time. To ensure proper curing of the logs:

Ignite a 2" flame and maintain it for 1 hour.

Burn the logs in consecutive 1 hour pe- riods raising the flame an additional 2" to full flame height for a total of three hours.

OPERATING

INSTRUCTIONS FOR

GA9000

Note: Operation instructions for GA9100 Remote Ready Valve/Pilot Kit will be included with the Kit.

1.STOP! Read the safety information, column one this page.

2.Make sure manual shutoff valve is fully open.

3.Press in and turn control knob clock-

wise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas around log set and near floor. If you smell gas, STOP! See Safety information, page 2 and Air For Combustion And Ventila- tion, pages 4 through 6. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise to the PILOT position and press in. Keep control knob pressed in for five (5) seconds.

Note: You may be running this log set for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 sec- onds. This will allow air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the rear of the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, con- tact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.

8.Turn control knob counterclockwise to the ON position. Burner should light. If burner does not light, call a qualified service person.

Control Knob

Ignitor

Pilot

 

 

ON

OFF

 

FROM "PILOT" POSITION

On

SLIGHT PUSH TO

Off

 

PULL PUSH

 

 

TURN OFF

 

ON OFF FROM "PILOT" POSITION

SLIGHT PUSH TO TURN OFF PULL PUSH

TURN OFF PULL PUSH

ON OFF FROM "PILOT" POSITION SLIGHT PUSH TO

Figure 21 - Ignitor and Control Knob

 

 

 

Thermo-

Pilot

 

 

couple

Figure 22 - Thermocouple and Pilot

12

901048

Image 12
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASRadco Burner Models CVSR18 CVDR24, and CVDR30Safety Information Radco Burners for Vented Natural GAS LogsProduct Identification Optional Product Features ON/OFF Safety VALVE/ Pilot KIT and PROPANE/LP ConversionRemote Control Ready Millivolt Safety VALVE/ Pilot KIT Remote Control AccessoriesAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Appliance LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From InsideBuilding Ventilation Air From OutdoorsInstallation Flue Opening SpecificationsVenting Specifications for Installation Check GAS TypeInstalling Damper Clamp Connecting to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemHearth KIT Assembly and Installation Kit AssemblyInstallation and Gas Connection Natural Gas InstallationPropane/LP Gas Conversion Burner Inlet FittingChanging Pilot Orifice Testing Burner for Leaks Installing the Grate and LogsAdding PAN Material Operating Appliance Troubleshooting To Turn OFF GAS To ApplianceShutting Off Burner Only pilot stays lit Top Gas leak. See Warning statement atClean pilot see Cleaning and Mainte Illustrated Parts Breakdown Radco Burner Models CVSR18 CVSR24, CPVSR18 CPVSR24Parts List Radco Burner Models CVSR18, CVSR24, CPVSR18, and CPVSR24Radco Burner Models CVDR18, CVDR24, and CVDR30 Radco Burner Models CVDR18 CVDR24, and CVDR30 KEY Part Number for CVDR18 CVDR24 CVDR30 Description QTYCleaning and Maintenance AccessoriesReplacement Parts Parts Centrals Decorative ASH BED Control Cover CdabkOrnamental Grate Enhancer GA9350 Ornamental Grate Enhancer GA9360Radco Burners for Vented Natural GAS Logs 901048 Warranty Information International

CPVSR18, and CVDR30, CPVSR24, CVSR24, CVDR24 specifications

Desa CVSR18, CVDR18, CVDR24, CVSR24, and CPVSR24 are a range of advanced heating solutions designed for various industrial and commercial applications. These systems combine a sophisticated blend of technology, efficiency, and ease of use, making them ideal for maintaining optimal thermal comfort.

The CVSR and CVDR series feature a unique vertical design that maximizes space efficiency while ensuring powerful heating capabilities. The model names indicate their heating capacities, with CVSR18 and CVDR18 offering output ratings of 18 kW, and the CVDR24 and CVSR24 providing a robust 24 kW. This scalability makes them suitable for a wide variety of environments, from large warehouses to smaller industrial facilities.

One of the key characteristics of these units is their high efficiency. Employing advanced combustion technology, the Desa heating systems reduce energy consumption while delivering superior heating performance. This not only translates to lower operational costs but also contributes to a reduced environmental footprint, aligning with contemporary sustainability goals.

The CVSR series utilizes a sealed combustion design, meaning that air is drawn from outside the building for combustion, improving indoor air quality and comfort. Meanwhile, the CVDR variants are designed for direct vent applications, allowing for flexible installation options. The direct vent feature ensures that exhaust gases are effectively expelled outside without interfering with indoor air circulation.

In addition to their energy efficiency and innovative design, the CPVSR24 model stands out due to its enhanced control capabilities. It includes smart technology integration that allows for remote monitoring and management, offering users greater control over their heating systems. This feature is particularly beneficial for businesses seeking to optimize operational efficiency by adjusting heating output based on real-time conditions.

Another notable aspect of these models is their durability. Constructed with robust materials, the Desa models are designed to withstand harsh operating conditions. Regular maintenance is made straightforward, ensuring longevity and reliability in performance.

Overall, Desa CVSR18, CVDR18, CVDR24, CVSR24, and CPVSR24 represent a comprehensive suite of heating solutions that prioritize performance, convenience, and sustainability. Their innovative features make them a strategic choice for those looking to enhance their heating systems while minimizing energy consumption and environmental impact.