Desa CVSR24, CPVSR18, CVDR24, CVSR18, CPVSR24, CVDR18, and CVDR30 Warranty Information, International

Page 24

WARRANTY INFORMATION

KEEP THIS WARRANTY

Model

Serial No.

Date Purchased

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY

VANGUARD VENTED GAS LOGS

DESA International warrants this product to be free from defects on burner system for three (3) years and logs for a lifetime from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this log set to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The log set MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective log set will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURA- TION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO THREE (3) YEARS ON BURNER SYSTEM AND A LIFETIME ON LOGS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

INTERNATIONAL

2701 Industrial Drive

P.O. Box 90004

Bowling Green, KY 42102-9004

www.desatech.com

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

901048-01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

901048 01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rev. A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOT A UPC

 

 

 

 

 

 

07/99

Image 24
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASRadco Burner Models CVSR18 CVDR24, and CVDR30Safety Information Radco Burners for Vented Natural GAS LogsProduct Identification Optional Product Features ON/OFF Safety VALVE/ Pilot KIT and PROPANE/LP ConversionRemote Control Ready Millivolt Safety VALVE/ Pilot KIT Remote Control AccessoriesAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Appliance LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From InsideBuilding Ventilation Air From OutdoorsInstallation Flue Opening SpecificationsVenting Specifications for Installation Check GAS TypeInstalling Damper Clamp Connecting to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemHearth KIT Assembly and Installation Kit AssemblyInstallation and Gas Connection Natural Gas InstallationPropane/LP Gas Conversion Burner Inlet FittingChanging Pilot Orifice Testing Burner for Leaks Installing the Grate and LogsAdding PAN Material Operating Appliance Troubleshooting To Turn OFF GAS To ApplianceShutting Off Burner Only pilot stays lit Top Gas leak. See Warning statement atClean pilot see Cleaning and Mainte Illustrated Parts Breakdown Radco Burner Models CVSR18 CVSR24, CPVSR18 CPVSR24Parts List Radco Burner Models CVSR18, CVSR24, CPVSR18, and CPVSR24Radco Burner Models CVDR18, CVDR24, and CVDR30 Radco Burner Models CVDR18 CVDR24, and CVDR30 KEY Part Number for CVDR18 CVDR24 CVDR30 Description QTYCleaning and Maintenance AccessoriesReplacement Parts Parts Centrals Decorative ASH BED Control Cover CdabkOrnamental Grate Enhancer GA9350 Ornamental Grate Enhancer GA9360Radco Burners for Vented Natural GAS Logs 901048 Warranty Information International

CPVSR18, and CVDR30, CPVSR24, CVSR24, CVDR24 specifications

Desa CVSR18, CVDR18, CVDR24, CVSR24, and CPVSR24 are a range of advanced heating solutions designed for various industrial and commercial applications. These systems combine a sophisticated blend of technology, efficiency, and ease of use, making them ideal for maintaining optimal thermal comfort.

The CVSR and CVDR series feature a unique vertical design that maximizes space efficiency while ensuring powerful heating capabilities. The model names indicate their heating capacities, with CVSR18 and CVDR18 offering output ratings of 18 kW, and the CVDR24 and CVSR24 providing a robust 24 kW. This scalability makes them suitable for a wide variety of environments, from large warehouses to smaller industrial facilities.

One of the key characteristics of these units is their high efficiency. Employing advanced combustion technology, the Desa heating systems reduce energy consumption while delivering superior heating performance. This not only translates to lower operational costs but also contributes to a reduced environmental footprint, aligning with contemporary sustainability goals.

The CVSR series utilizes a sealed combustion design, meaning that air is drawn from outside the building for combustion, improving indoor air quality and comfort. Meanwhile, the CVDR variants are designed for direct vent applications, allowing for flexible installation options. The direct vent feature ensures that exhaust gases are effectively expelled outside without interfering with indoor air circulation.

In addition to their energy efficiency and innovative design, the CPVSR24 model stands out due to its enhanced control capabilities. It includes smart technology integration that allows for remote monitoring and management, offering users greater control over their heating systems. This feature is particularly beneficial for businesses seeking to optimize operational efficiency by adjusting heating output based on real-time conditions.

Another notable aspect of these models is their durability. Constructed with robust materials, the Desa models are designed to withstand harsh operating conditions. Regular maintenance is made straightforward, ensuring longevity and reliability in performance.

Overall, Desa CVSR18, CVDR18, CVDR24, CVSR24, and CPVSR24 represent a comprehensive suite of heating solutions that prioritize performance, convenience, and sustainability. Their innovative features make them a strategic choice for those looking to enhance their heating systems while minimizing energy consumption and environmental impact.