CONNECTING TO GAS SUPPLY

WARNING: This appliance re- quires a 3/8" NPT (National Pipe Thread) inlet connection to the pressure regulator.

WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.

WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as well-head gas.

Installation must include equipment shutoff valve, ground joint union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be up- stream from heater (see Figure 12).

IMPORTANT: Install an equipment shutoff valve in an accessible location. The equip- ment shutoff valve is for turning on or shutting off the gas to the appliance.

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

Install sediment trap in supply line as shown in Figure 12. Locate sediment trap where it is within reach for cleaning. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings.

IMPORTANT: Check gas line pressure be- fore connecting heater to gas line. Gas line pressure must be no greater than 14 inches of water. If gas line pressure is higher, heater regulator damage could occur.

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe 3/8" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.

3/8" NPT Pipe Nipple

Ground Joint Union

Equipment

Shutoff Valve *

From Gas Meter (7" W.C. to

10.5" W.C. Pressure)

3" Minimum

Figure 12 - Gas Connection

Pressure

Regulator

Heater

Cabinet

Tee Joint

 

 

 

 

 

 

 

 

Reducer

 

 

 

Test

Bushing to

 

 

 

 

 

 

Gauge

1/8" NPT

 

 

 

Connection *

1/8" NPT

 

 

 

 

Plug Tap

 

 

 

 

 

 

 

 

Tee

 

 

 

 

 

 

 

 

 

 

 

 

Joint

 

 

 

 

 

Pipe

 

Sediment

 

 

Trap

Nipple

 

 

 

 

 

 

Cap

 

 

 

 

 

 

*A CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA/AGA design-certified equipment shutoff valve from your dealer. See Accessory, page 16.

Continued

105562

9

Image 9
Contents What to do if YOU Smell GAS Infrared VENT-FREE Natural GAS HeaterNatural GAS Heater Safety InformationProduct Identification Product FeaturesLocal Codes UnpackingProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Fresh AIR for Combustion and VentilationVentilation Air From Inside Building Ventilation Air From OutdoorsInstallation Items InstallationInstalling Heater to Wall Check GAS TypeMethods For Attaching Mounting Bracket To Wall Installing Bottom Mounting ScrewsMarking Screw Locations Attaching Mounting Bracket To WallGas Connection Connecting to GAS SupplyOperating For Your SafetyHeater Checking GAS ConnectionsOperating Heater Manual Lighting ProcedureLighting Instructions To Select Heating LevelInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingTurn control knob until it locks at desired Observed Problem Possible Cause Replacement Parts SpecificationsTechnical Service AccessoryParts Centrals FA-2B Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListWarranty Information

FA-2B specifications

Desa FA-2B is a highly advanced facility designed for modern eco-friendly living, combining sustainability with cutting-edge technology to create a harmonious environment. One of the standout features of the Desa FA-2B is its commitment to zero energy use, achieved through a range of innovative technologies that harness renewable resources.

At the core of Desa FA-2B is its extensive use of solar energy. The facility is equipped with solar panels that generate power sufficient to meet the energy needs of its residents. This solar infrastructure not only reduces reliance on conventional energy sources but also contributes to lowering overall carbon emissions. Additionally, the integration of energy storage systems allows for the accumulation and usage of solar energy during nighttime or cloudy days.

In terms of water conservation, Desa FA-2B incorporates rainwater harvesting systems, which collect rainwater from rooftops and store it for various uses, such as irrigation and non-potable applications. Advanced filtration technology ensures that the harvested water is suitable for these purposes, reflecting a commitment to resource efficiency. Furthermore, greywater recycling systems play a pivotal role in minimizing water waste by treating and reusing water from sinks and showers.

The architectural design of Desa FA-2B emphasizes open spaces and natural light. Large windows and strategically placed skylights minimize the need for artificial lighting, creating a bright and welcoming atmosphere for residents. The building materials used are sustainably sourced, emphasizing both durability and aesthetics. The use of natural insulation materials ensures energy efficiency while maintaining comfort throughout the seasons.

Smart home technologies are also prevalent in Desa FA-2B. Connected devices allow residents to monitor and control energy use, security systems, and even appliance operation through their smartphones. This level of control not only enhances convenience but also empowers residents to make informed decisions about their resource consumption.

Community spaces within Desa FA-2B promote social interaction and strengthen community ties. Shared gardens, recreational areas, and communal kitchens foster a sense of belonging among residents, encouraging them to participate in the upkeep and enjoyment of their environment.

In summary, Desa FA-2B exemplifies the future of sustainable living through its innovative technologies, commitment to energy efficiency, and community-oriented design. By integrating solar power, water conservation systems, smart technologies, and open architectural designs, Desa FA-2B offers a blueprint for eco-friendly living that prioritizes both environmental sustainability and resident comfort.