OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed and control

1.

Ignitor electrode positioned wrong

1.

Replace ignitor

knob is pressed in and turned to the PILOT

2.

Ignitor electrode broken

2.

Replace ignitor

position, there is no spark at ODS/pilot

3.

Ignitor electrode not connected to igni-

3.

Reconnect ignitor cable

 

 

tor cable

 

 

 

4.

Ignitor cable pinched or wet

4.

Free ignitor cable if pinched by any

 

 

 

 

metal or tubing. Keep ignitor cable dry

 

5.

Broken ignitor cable

5.

Replace ignitor cable

 

6.

Bad piezo ignitor

6.

Replace control valve (piezo is part of

 

 

 

 

control valve)

 

 

 

 

 

When ignitor button is pressed and control

1.

Gas supply turned off or equipment

1.

Turn on gas supply or open equipment

knob is pressed in and turned to the PILOT

 

shutoff valve closed

 

shutoff valve

position, there is spark at ODS/pilot but no

2.

Control knob not in PILOT position

2.

Turn control knob to PILOT position

ignition

3.

Control knob not pressed in while in

3.

Press in control knob while in PILOT

 

 

PILOT position

 

position

 

4.

Air in gas lines when installed

4.

Continue holding down control knob.

 

 

 

 

Repeat igniting operation until air is

 

 

 

 

removed

 

5.

ODS/pilot is clogged

5.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 12) or replace ODS/

 

 

 

 

pilot assembly

 

6.

Gas regulator setting is not correct

6.

Replace gas regulator

 

 

 

 

 

ODS/pilot lights but flame goes out when

1.

Control knob not fully pressed in

1.

Press in control knob fully

control knob is released

2.

Control knob not pressed in long enough

2.

After ODS/pilot lights, keep control

 

 

 

 

knob pressed in 10 seconds

 

3.

Equipment shutoff valve not fully open

3.

Fully open equipment shutoff valve

 

4.

Thermocouple connection loose at con-

4.

Hand tighten until snug, then tighten 1/4

 

 

trol valve

 

turn more

 

5.

Pilot flame not touching thermocouple,

5.

A) Contact local natural gas company

 

 

which allows thermocouple to cool,

 

B) Clean ODS/pilot (see Cleaning and

 

 

causing pilot flame to go out. This prob-

 

Maintenance, page 12) or replace ODS/

 

 

lem could be caused by one or both of

 

pilot assembly

 

 

the following:

 

 

 

 

A) Low gas pressure

 

 

 

 

B) Dirty or partially clogged ODS/pilot

 

 

 

6.

Thermocouple damaged

6.

Replace thermocouple

 

7.

Control valve damaged

7.

Replace control valve

www.desatech.com

Continued

105562

13

Image 13
Contents What to do if YOU Smell GAS Infrared VENT-FREE Natural GAS HeaterNatural GAS Heater Safety InformationProduct Identification Product FeaturesLocal Codes UnpackingProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Fresh AIR for Combustion and VentilationVentilation Air From Inside Building Ventilation Air From OutdoorsInstallation Items InstallationInstalling Heater to Wall Check GAS TypeMethods For Attaching Mounting Bracket To Wall Installing Bottom Mounting ScrewsMarking Screw Locations Attaching Mounting Bracket To WallGas Connection Connecting to GAS SupplyOperating For Your SafetyHeater Checking GAS ConnectionsOperating Heater Manual Lighting ProcedureLighting Instructions To Select Heating LevelInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingTurn control knob until it locks at desired Observed Problem Possible Cause Replacement Parts SpecificationsTechnical Service AccessoryParts Centrals FA-2B Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListWarranty Information

FA-2B specifications

Desa FA-2B is a highly advanced facility designed for modern eco-friendly living, combining sustainability with cutting-edge technology to create a harmonious environment. One of the standout features of the Desa FA-2B is its commitment to zero energy use, achieved through a range of innovative technologies that harness renewable resources.

At the core of Desa FA-2B is its extensive use of solar energy. The facility is equipped with solar panels that generate power sufficient to meet the energy needs of its residents. This solar infrastructure not only reduces reliance on conventional energy sources but also contributes to lowering overall carbon emissions. Additionally, the integration of energy storage systems allows for the accumulation and usage of solar energy during nighttime or cloudy days.

In terms of water conservation, Desa FA-2B incorporates rainwater harvesting systems, which collect rainwater from rooftops and store it for various uses, such as irrigation and non-potable applications. Advanced filtration technology ensures that the harvested water is suitable for these purposes, reflecting a commitment to resource efficiency. Furthermore, greywater recycling systems play a pivotal role in minimizing water waste by treating and reusing water from sinks and showers.

The architectural design of Desa FA-2B emphasizes open spaces and natural light. Large windows and strategically placed skylights minimize the need for artificial lighting, creating a bright and welcoming atmosphere for residents. The building materials used are sustainably sourced, emphasizing both durability and aesthetics. The use of natural insulation materials ensures energy efficiency while maintaining comfort throughout the seasons.

Smart home technologies are also prevalent in Desa FA-2B. Connected devices allow residents to monitor and control energy use, security systems, and even appliance operation through their smartphones. This level of control not only enhances convenience but also empowers residents to make informed decisions about their resource consumption.

Community spaces within Desa FA-2B promote social interaction and strengthen community ties. Shared gardens, recreational areas, and communal kitchens foster a sense of belonging among residents, encouraging them to participate in the upkeep and enjoyment of their environment.

In summary, Desa FA-2B exemplifies the future of sustainable living through its innovative technologies, commitment to energy efficiency, and community-oriented design. By integrating solar power, water conservation systems, smart technologies, and open architectural designs, Desa FA-2B offers a blueprint for eco-friendly living that prioritizes both environmental sustainability and resident comfort.