Desa VVDA30M, VVSA24M, VVDA24M Local Codes, Product Identification, Unpacking, Product Feature

Page 3

SAFETY INFORMATION

Continued

9.Do not use a blower insert, heat exchanger insert or other ac- cessory not approved for use with this log set.

10.The installation and provisions for combustion and ventilation air must conform with the National Fuel Gas Codes, ANSI Z233.1/ NFPA 54, Section 5.3, Air for Combustion and Ventilation.

11.Do not run log set

where flammable liquids or vapors are used or stored

under dusty conditions

12.Do not burn solid fuel in the fireplace after installing the log set. Do not use this log set to cook food or burn paper or other objects.

13.Log set becomes very hot when in use. Keep children and adults away from hot surface to avoid burns or clothing ignition. Log set will remain hot for a time after shutdown. Allow surface to cool before touching.

14.Carefully supervise young children when they are in the room with log set.

15.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

16.To help prevent breakage, new logs must be broken-in (see Curing Logs page 9).

17.Turn log set off and let cool before servicing, installing, or repairing. Only a qualified service person should install, ser- vice, or repair log set.

18.Keep the appliance area clear and free from combustible ma- terials, gasoline and other flammable vapors and liquids.

19.Provide adequate clearances around air openings.

LOCAL CODES

Install and use log set with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

SAFETY INFORMATION

LOCAL CODES 3

PRODUCT IDENTIFICATION

UNPACKING

PRODUCT FEATURE

PRODUCT IDENTIFICATION

Grate Steps

Grate

Burner Burner

Pan Clamp

Burner

Manifold

Figure 1 - Product Identification (VVDA24 Shown)

Hearth Kit Model ________________________

Serial Number __________________________

Log Set Model __________________________

UNPACKING

CAUTION: Do not remove the metal data plates from the burner pan. The data plates contain impor- tant warranty and safety information.

1.Remove logs, hearth kit, pan materials, and hardware from carton.

2.Remove all protective packaging applied to logs and base for shipment.

3.Check all items for any shipping damage. If damaged, promptly inform dealer where you bought the product.

PRODUCT FEATURE

ON/OFF SAFETY VALVE/PILOT

Unit is tested and approved to ANSI Z21.60a-2000and CSA 2.26a- 2000 as a vented decorative appliance. It is supplied with the parts and instructions to convert to propane/LP gas use.

For more information, visit www.desatech.com

901268

Image 3
Contents What to do if YOU Smell GAS GAS LOG TM Vented Decorative ApplianceSafety Information Table of ContentsProduct Identification Product FeatureON/OFF Safety VALVE/PILOT Local CodesCheck GAS Type InstallationVenting Specifications for Installation Flue Opening SpecificationsConnecting to GAS Supply Installing Damper ClampChecking GAS Connections Hearth PAN InstallationRemoving/Installing Cover, Control Knob, Testing Burner for Leaks Installing the Grate and LogsAdding PAN Material For Your Safety Read Before Lighting Operating ApplianceCuring Logs Lighting Instructions To Turn OFF GAS to Appliance Cleaning MaintenancePilot Assembly Inspecting BurnersObserved Problem Possible Cause Remedy TroubleshootingBe caused by one or both of the following Remedy Observed Problem Possible CauseVVSA18M, VVSA24M, VVDA18M VVDA24M and VVDA30M Illustrated Parts BreakdownParts List LOG SET Models VSLR18, VSLR24, VDLCR18 VDLCR24, and VDLCR30 Illustrated Parts Break DownParts List Models FVSA18M FVSA24M, FVDA18M FVDA24M and FVDA30M Parts Available not Shown LOG SET Models FSLR18, FSLR24 FDLCR18, FDLCR24 and FDLCR30 Parts List Models CVDA18M, CVDA24M and CVDA30M KEY Part Number for CVDA18M CVDA24M CVDA30M Description QTY LOG SET Models CVSA18M CVSA24M, CPVSA18M CPVSA24M CVSA18M, CVSA24M, CPVSA18M and CPVSA24M Accessories Replacement Parts901268 Limited Warranty Vented GAS Logs Warranty Information
Related manuals
Manual 30 pages 19.19 Kb

VVDA30M, VVDA24M, VVDA18M, VVSA18M, VVSA24M specifications

Desa VVSA24M, VVSA18M, VVDA18M, VVDA24M, and VVDA30M are advanced heating solutions that combine efficiency, versatility, and user-friendly features. These models are popular among consumers looking for reliable heating systems for their homes or businesses.

The Desa VVSA series, which includes the VVSA24M and VVSA18M models, is designed for high-performance utilization, making them ideal for medium to large spaces. These units utilize advanced radiant heating technology, which effectively warms up a room by emitting infrared heat, making them energy-efficient and environmentally friendly. The VVSA24M model offers a higher heat output, catering to larger areas, while the VVSA18M is suitable for smaller spaces, providing ample warmth without the added bulk.

On the other hand, the Desa VVDA series comprises the VVDA18M, VVDA24M, and VVDA30M models. This series is notable for its dual-fuel capability, allowing users to choose between propane and natural gas for fuel, enhancing flexibility depending on availability and cost. The VVDA variances cater to different heating needs, with the VVDA30M boasting the highest output, making it perfect for extensive commercial settings or sizable residential spaces. The VVDA18M and VVDA24M serve as excellent alternatives for smaller establishments, maintaining efficient heating performance while reducing energy consumption.

One of the standout features across all these models is the integrated electronic ignition system, which ensures a reliable start and enhances safety by eliminating the need for a continuous pilot light. Additionally, these units are equipped with advanced thermostat controls, allowing users to set their desired temperature accurately and maintain a consistent level of comfort throughout the space.

These Desa models also feature durable construction with high-quality materials, ensuring longevity and resistance to wear and tear. Their sleek designs mean they can fit seamlessly into various interior decors, making them not just functional but also aesthetically pleasing.

In summary, Desa VVSA24M, VVSA18M, VVDA18M, VVDA24M, and VVDA30M encompass a range of heating solutions that cater to diverse needs and preferences. With their innovative technologies, user-friendly features, and robustness, these units exemplify what modern heating systems should offer. They are not just about warmth; they bring comfort, efficiency, and flexibility to any space.