Desa VVSA18M, VVSA24M, VVDA24M, VVDA18M Check GAS Type, Venting Specifications for Installation

Page 4

4

INSTALLATION

Flue Opening Specifications Check Gas Type

Venting Specifications for Installation

INSTALLATION

CAUTION: Do not remove the metal data plates attached to the burner pan. The data plates contain important warranty and safety information.

WARNING: Before installing in a solid fuel burn- ing fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and distribute soot within the house. Inspect chimney flue for damage.

NOTICE: Installation, service, and repair of this appli- ance must be performed by a qualified installer, ser- vice agency, company or gas supplier experienced with this type of gas appliance. Only factory autho- rized components listed in these instructions may be used in accordance with the manufacturer’s instruc- tions and all codes and requirements of the authority having jurisdiction. Any modifications to this kit, or use of unauthorized components or accessory items will void the manufacturer’s warranty, and may result in a hazardous condition.

CHECK GAS TYPE

Use only natural gas. If your gas supply is not natural gas, you must convert the appliance to propane/LP. Follow the instruc- tions on pages 6 and 7.

If the fireplace does not have a gas supply shut-off valve, one must be installed.

VENTING SPECIFICATIONS FOR

INSTALLATION

The fireplace chimney flue and vent must be drafting properly. To check the vent for proper drafting: Light a tightly rolled newspa- per on one end and place it at the inside front edge of the fireplace. Observe the smoke and be sure the vent is properly drawing it up the chimney. If the smoke spills out into the room, extinguish the flame and remove any obstruction until proper venting is achieved.

The chimney flue damper must be fixed open to provide a minimum of 81 sq. in. of free air opening during operation of this log set. A multipurpose damper clamp is provided to fix the damper in position.

The minimum flue sizes shown in Figure 2 are based on a 6' chimney height using round pipe. Your minimum flue size will vary based on input rate and chimney height. Refer to the National Fuel Gas Code ANSI Z223.1/NFPA 54, Section 6.6, for details.

FLUE OPENING SPECIFICATIONS

Note: This vented appliance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of noncom- bustible material.

The charts in Figure 2 indicate technical information regarding the installation of your gas log set. Please make sure that all of the specifications shown are applicable before installation is attempted.

The fireplace must include a working flue and venting system with the minimum openings shown in the Figure 2.

 

Btu Input

Btu Input

Burner Orifice

 

DESCRIPTION

Natural

Propane/LP

Natural

Propane/LP

Gas

Gas

In.

Num.

In.

 

Num.

18" Single Burner

50,000

40,000

.116

32

.081

 

46

24" Single Burner

60,000

50,000

.120

31

.082

 

45

18" Dual Burner

55,000

45,000

.116

32

.082

 

45

24" Dual Burner

65,000

55,000

.138

29

.086

 

44

30" Dual Burner

70,000

60,000

.1405

28

.089

 

43

 

 

 

 

 

 

 

 

Figure 2 - Technical Information Charts

MINIMUM FIREBOX SIZES

LOG

FRONT

BACK

 

 

MINIMUM

SIZE

WIDTH

WIDTH*

DEPTH

HEIGHT

FLUE SIZE

 

 

 

 

 

 

18"

34"

16"

14"

18"

8" diam.

24"

35 3/4"

17"

15 1/2"

18"

8" diam.

30"

42"

27"

18"

18"

9" diam.

*At depth indicated

SPECIFICATIONS (W.C.)

 

FUEL INLET

MANIFOLD

 

PRESSURE

PRESSURE

 

 

 

 

 

 

 

Min.

Max.

 

NG

 

7

10.5

6

LP

 

11

14

10

For morevisit www..com

901268

Image 4
Contents GAS LOG TM Vented Decorative Appliance What to do if YOU Smell GASTable of Contents Safety InformationProduct Feature ON/OFF Safety VALVE/PILOTLocal Codes Product IdentificationInstallation Venting Specifications for InstallationFlue Opening Specifications Check GAS TypeInstalling Damper Clamp Connecting to GAS SupplyHearth PAN Installation Checking GAS ConnectionsRemoving/Installing Cover, Control Knob, Installing the Grate and Logs Testing Burner for LeaksAdding PAN Material Operating Appliance For Your Safety Read Before LightingCuring Logs Lighting Instructions Cleaning Maintenance Pilot AssemblyInspecting Burners To Turn OFF GAS to ApplianceTroubleshooting Observed Problem Possible Cause RemedyBe caused by one or both of the following Observed Problem Possible Cause RemedyIllustrated Parts Breakdown VVSA18M, VVSA24M, VVDA18M VVDA24M and VVDA30MParts List Illustrated Parts Break Down LOG SET Models VSLR18, VSLR24, VDLCR18 VDLCR24, and VDLCR30Parts List Models FVSA18M FVSA24M, FVDA18M FVDA24M and FVDA30M Parts Available not Shown LOG SET Models FSLR18, FSLR24 FDLCR18, FDLCR24 and FDLCR30 Parts List Models CVDA18M, CVDA24M and CVDA30M KEY Part Number for CVDA18M CVDA24M CVDA30M Description QTY LOG SET Models CVSA18M CVSA24M, CPVSA18M CPVSA24M CVSA18M, CVSA24M, CPVSA18M and CPVSA24M Replacement Parts Accessories901268 Warranty Information Limited Warranty Vented GAS Logs
Related manuals
Manual 30 pages 19.19 Kb

VVDA30M, VVDA24M, VVDA18M, VVSA18M, VVSA24M specifications

Desa VVSA24M, VVSA18M, VVDA18M, VVDA24M, and VVDA30M are advanced heating solutions that combine efficiency, versatility, and user-friendly features. These models are popular among consumers looking for reliable heating systems for their homes or businesses.

The Desa VVSA series, which includes the VVSA24M and VVSA18M models, is designed for high-performance utilization, making them ideal for medium to large spaces. These units utilize advanced radiant heating technology, which effectively warms up a room by emitting infrared heat, making them energy-efficient and environmentally friendly. The VVSA24M model offers a higher heat output, catering to larger areas, while the VVSA18M is suitable for smaller spaces, providing ample warmth without the added bulk.

On the other hand, the Desa VVDA series comprises the VVDA18M, VVDA24M, and VVDA30M models. This series is notable for its dual-fuel capability, allowing users to choose between propane and natural gas for fuel, enhancing flexibility depending on availability and cost. The VVDA variances cater to different heating needs, with the VVDA30M boasting the highest output, making it perfect for extensive commercial settings or sizable residential spaces. The VVDA18M and VVDA24M serve as excellent alternatives for smaller establishments, maintaining efficient heating performance while reducing energy consumption.

One of the standout features across all these models is the integrated electronic ignition system, which ensures a reliable start and enhances safety by eliminating the need for a continuous pilot light. Additionally, these units are equipped with advanced thermostat controls, allowing users to set their desired temperature accurately and maintain a consistent level of comfort throughout the space.

These Desa models also feature durable construction with high-quality materials, ensuring longevity and resistance to wear and tear. Their sleek designs mean they can fit seamlessly into various interior decors, making them not just functional but also aesthetically pleasing.

In summary, Desa VVSA24M, VVSA18M, VVDA18M, VVDA24M, and VVDA30M encompass a range of heating solutions that cater to diverse needs and preferences. With their innovative technologies, user-friendly features, and robustness, these units exemplify what modern heating systems should offer. They are not just about warmth; they bring comfort, efficiency, and flexibility to any space.