Desa VP600BA Operating Heater, Checking GAS Connections, For Your Safety Read Before Lighting

Page 10

®

VENT FREE PROPANE/LP GAS HEATER

INSTALLATION

Continued

CHECKING GAS

CONNECTIONS

WARNING: Test all gas pip- ing and connections for leaks after installation or servicing. Correct all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

CAUTION: Make sure exter- nal regulator has been installed between propane/LP supply and heater. See guidelines under Con- necting to Gas Supply, page 9.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1. Disconnect appliance with its appliance

main gas valve (control valve) and equip-

ment shutoff valve from gas supply pip-

ing system. Pressures in excess of 1/2 psig

will damage heater regulator.

2.Pressurize supply piping system by ei- ther using compressed air or opening propane/LP supply tank valve.

3.Check all joints from propane/LP sup- ply tank to equipment shutoff valve (see Figure 15). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Pressure Testing Heater Gas Connections

1.Open equipment shutoff valve (see Fig- ure 14).

2.Open propane/LP supply tank valve.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from equipment shutoff valve to control valve (see Figure 15). Apply mixture of liquid soap and wa- ter to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 10 and 11). Check the rest of the internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 11).

8.Replace front panel.

Open

Equipment

Shutoff

Valve

OPERATING

HEATER

FOR YOUR SAFETY

READ BEFORE

LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these in- structions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

2.

Cap off open end of gas pipe where

 

equipment shutoff valve was connected.

3.

Pressurize supply piping system by ei-

 

ther using compressed air or opening

 

propane/LP supply tank valve.

4.

Check all joints of gas supply piping

 

system. Apply mixture of liquid soap

 

and water to gas joints. Bubbles form-

 

ing show a leak.

5.

Correct all leaks at once.

6.

Reconnect heater and equipment

 

shutoff valve to gas supply. Check re-

 

connected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Fig- ure 14).

 

C. Use only your hand to push in or

 

turn the gas control knob. Never use

Closed

tools. If the knob will not push in or

turn by hand, don’t try to repair it,

 

Figure 14 - Equipment Shutoff Valve

call a qualified service technician or

Control Valve Location

gas supplier. Force or attempted re-

pair may result in a fire or explosion.

 

D. Do not use this appliance if any part

 

has been under water. Immediately

Propane/LP

call a qualified service technician to

Supply

inspect the appliance and to replace

Tank

any part of the control system and

 

any gas control which has been un-

 

der water.

Equipment

Shutoff

Valve

 

Figure 15 - Checking Gas Joints

10

104272

Image 10
Contents VP600BA What to do if YOU Smell GASSafety Information Vent Free PROPANE/LP GAS HeaterLocal Codes Product FeaturesProduct Identification UnpackingUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installing Heater to Wall InstallationInstallation Items Locating HeaterPlacing Heater On Mounting Screws Installing Two Mounting ScrewsInstalling Bottom Mounting Screw Removing Front Panel Of HeaterConnecting to GAS Supply External Regulator With Vent Pointing DownPressure Testing Heater Gas Connections For Your Safety Read Before LightingPressure Testing Gas Supply Piping System Operating HeaterTo Turn OFF GAS To Appliance Manual Lighting ProcedureLighting Instructions Shutting Off HeaterPilot Flame Pattern Cleaning Burner Pilot AIR Inlet HoleInspecting Burner Burner Flame PatternTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Observed Problem Possible Cause Illustrated Parts Breakdown VP600BAParts List KEY Part Number Description QTYService Hints SpecificationsReplacement Parts Service Publications Technical104272 Warranty Information

VP600BA specifications

The Desa VP600BA is a highly regarded space heater known for its efficiency, versatility, and user-friendly design. Developed with the latest technology, this model prioritizes both performance and comfort, making it an ideal choice for various settings.

One of the standout features of the Desa VP600BA is its advanced heating capabilities. The heater delivers a robust output of up to 6000 BTUs, allowing it to effectively heat larger areas such as living rooms, workshops, or garages. Its efficiency is complemented by a thermostat control, which automatically regulates the temperature to ensure consistent warmth while conserving energy. This feature not only enhances comfort but also helps reduce energy costs.

In terms of design, the VP600BA boasts a compact and portable structure, making it easy to move from one room to another. This portability is especially beneficial for users who require flexibility in heating options. The heater is equipped with sturdy handles that facilitate transport, enabling users to adjust their heating based on where they need it most.

Safety is another key aspect of the Desa VP600BA. The heater features a built-in overheat shut-off mechanism, which automatically turns off the unit if it detects temperatures exceeding safe limits. This feature mitigates the risk of fires, providing peace of mind when operating the heater. Additionally, the unit is designed with a safety tip-over switch that shuts off the heater if it is accidentally knocked over.

The Desa VP600BA also integrates modern technologies such as a user-friendly control panel that allows for easy adjustments of settings. The digital display provides clear visibility of the current temperature and settings, making it intuitive to operate even for those less familiar with heating appliances.

Durability is another significant characteristic of the VP600BA. Constructed with high-quality materials, it is designed to withstand the demands of daily use. The outer casing is not only durable but also stylish, fitting seamlessly into any home or professional environment.

In conclusion, the Desa VP600BA embodies a combination of efficiency, safety, and user-friendly features. With its powerful heating capabilities, portability, and modern technological integration, it stands out as a leading choice for anyone in need of reliable heating solutions. Whether for residential or commercial use, the Desa VP600BA proves to be a dependable option for maintaining comfort during colder months.