Desa VP600BA Lighting Instructions, To Turn OFF GAS To Appliance, Manual Lighting Procedure

Page 11

OWNER’S MANUAL

OPERATING

HEATER

Continued

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information, page 10, column 3.

2.Make sure equipment shutoff valve is fully open.

3. Turn control knob clockwise Clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information on page 10, column 3. If you don’t smell gas, go to the next step.

5.Press in control knob and turn coun-

terclockwise C-clockwiseto the PILOT position. Keep control knob pressed in for five (5) seconds (see Figure 16).

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. The pilot can be seen through the glass panel. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, refer to Troubleshooting, pages 13 through 15. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 3 through 7.

8.Turn control knob counterclockwise

C-clockwiseto the HIGH position. The main burner should light. Set control knob to any heat level between HIGH and LOW. To turn control knob from HIGH to a lower setting, press in the control knob and turn counterclock-

wise C-clockwise .

Note: Both HIGH and LOW are locked positions. You must press in control knob before turning it from these positions.

CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

Ignitor Button

Control Knob

PILOT OFF

HIGH

IGNITOR

LOW

Figure 16 - Control Knob In The OFF Position

Ignitor Pilot

Thermocouple Electrode Burner

Figure 17 - Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise Clockwise to the PILOT position.

2.Press in control knob and turn clock- wise Clockwise to the OFF position.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise Clockwise to the PILOT position.

MANUAL LIGHTING

PROCEDURE

1.Remove front panel (see Figure 10, page 8).

2.Follow steps 1 through 5 under Light- ing Instructions.

3.With control knob pressed in, strike match. Hold match to pilot until pi- lot lights.

4.Keep control knob pressed in for 30 seconds after pilot is lit. After 30 sec- onds, release control knob. Follow step 8 under Lighting Instructions.

5.Replace front panel.

104272

11

Image 11
Contents What to do if YOU Smell GAS VP600BAVent Free PROPANE/LP GAS Heater Safety InformationUnpacking Product FeaturesProduct Identification Local CodesConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Locating Heater InstallationInstallation Items Installing Heater to WallRemoving Front Panel Of Heater Installing Two Mounting ScrewsInstalling Bottom Mounting Screw Placing Heater On Mounting ScrewsExternal Regulator With Vent Pointing Down Connecting to GAS SupplyOperating Heater For Your Safety Read Before LightingPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsShutting Off Heater Manual Lighting ProcedureLighting Instructions To Turn OFF GAS To ApplianceBurner Flame Pattern Cleaning Burner Pilot AIR Inlet HoleInspecting Burner Pilot Flame PatternObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Observed Problem Possible Cause VP600BA Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListService Publications Technical SpecificationsReplacement Parts Service Hints104272 Warranty Information

VP600BA specifications

The Desa VP600BA is a highly regarded space heater known for its efficiency, versatility, and user-friendly design. Developed with the latest technology, this model prioritizes both performance and comfort, making it an ideal choice for various settings.

One of the standout features of the Desa VP600BA is its advanced heating capabilities. The heater delivers a robust output of up to 6000 BTUs, allowing it to effectively heat larger areas such as living rooms, workshops, or garages. Its efficiency is complemented by a thermostat control, which automatically regulates the temperature to ensure consistent warmth while conserving energy. This feature not only enhances comfort but also helps reduce energy costs.

In terms of design, the VP600BA boasts a compact and portable structure, making it easy to move from one room to another. This portability is especially beneficial for users who require flexibility in heating options. The heater is equipped with sturdy handles that facilitate transport, enabling users to adjust their heating based on where they need it most.

Safety is another key aspect of the Desa VP600BA. The heater features a built-in overheat shut-off mechanism, which automatically turns off the unit if it detects temperatures exceeding safe limits. This feature mitigates the risk of fires, providing peace of mind when operating the heater. Additionally, the unit is designed with a safety tip-over switch that shuts off the heater if it is accidentally knocked over.

The Desa VP600BA also integrates modern technologies such as a user-friendly control panel that allows for easy adjustments of settings. The digital display provides clear visibility of the current temperature and settings, making it intuitive to operate even for those less familiar with heating appliances.

Durability is another significant characteristic of the VP600BA. Constructed with high-quality materials, it is designed to withstand the demands of daily use. The outer casing is not only durable but also stylish, fitting seamlessly into any home or professional environment.

In conclusion, the Desa VP600BA embodies a combination of efficiency, safety, and user-friendly features. With its powerful heating capabilities, portability, and modern technological integration, it stands out as a leading choice for anyone in need of reliable heating solutions. Whether for residential or commercial use, the Desa VP600BA proves to be a dependable option for maintaining comfort during colder months.