Desa CDR3924PT installation manual Troubleshooting, Observed Problem Possible Cause Remedy

Page 20

TROUBLESHOOTING

WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.

Note: All troubleshooting items are listed in order of operation.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

When ignitor button is pressed,

1. Ignitor electrode not con-

1.

Reconnect ignitor cable

there is no spark at ODS/pilot

 

nected to ignitor cable

2.

Free ignitor cable if pinched

 

2.

Ignitor cable pinched or wet

 

 

 

 

by any metal or tubing. Keep

 

 

 

 

ignitor cable dry

 

3.

Broken ignitor cable

3.

Replace ignitor cable

 

4.

Bad ignitor

4.

Replace ignitor

 

5.

Ignitor electrode positioned

5.

Replace pilot assembly

 

 

wrong

6.

Replace pilot assembly

 

6.

Ignitor electrode broken

 

7.

Battery not installed, battery

7.

Install new alkaline battery

 

 

power low, or battery not

 

in electronic ignitor. Verify

 

 

installed correctly

 

battery is installed correctly

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1.Gas supply turned off or equip- ment shutoff valve closed

2.Control knob not in PILOT position

3.Control knob not pressed in while in PILOT position

4.Air in gas lines when in- stalled

5.Depleted gas supply (pro- pane/LP only)

6.ODS/pilot is clogged

7.Gas regulator setting is not correct

1.Turn on gas supply or open equipment shutoff valve

2.Turn control knob to PILOT position

3.Press in control knob while in PILOT position

4.Continue holding down con- trol knob. Repeat igniting op- eration until air is removed

5.Contact local propane/LP gas company

6.Clean ODS/pilot (see Cleaning and Maintenance, page 19) or replace ODS/pilot assembly

7.Replace gas regulator

20

www.desatech.com

113183-01A

Image 20
Contents What to do if YOU Smell GAS Thermostat Models CDR3924NT and CDR3924PTTable of Contents Safety Information Local Codes Product Features Product IdentificationAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Confined and Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Check GAS TypeInstallation and Clearances for VENT-FREE Operation RearWidth 20 1/4Determining Minimum Mantel Clearance When Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installation Items NeededConnecting to GAS Supply External Regulator With Vent Pointing DownChecking GAS Connections Propane/LP FromNatural From Gas Test Pressures In Excess Of 1/2 Psig 3.5 kPaInstalling Logs Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaAttaching Grate to Base Assembly Adding Lava RockLighting Instructions For Your Safety Read Before LightingOperating Heater Thermostat Control Operation Manual Lighting Procedure To Turn OFF GAS To Appliance Technical Service Inspecting BurnersPilot Flame Pattern Burner Flame PatternsLogs Cleaning MaintenanceBurner Injector Holders and Pilot AIR Inlet Holes Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Cold Minute Air in gas line Operate burners until air is Gas leak. See Warning Optional Positioning Thermostat Sensing Bulb For Masonry and FACTORY- Built Metal FireplaceSpecifications Replacement PartsService Hints AccessoriesIllustrated Parts Breakdown Models CDR3924PT and CDR3924NTParts List Limited Warranty Comfort Glow VENT-FREE GAS LOG Heaters Warranty InformationKeep this Warranty