Desa CDR3924PT installation manual Installation, Check GAS Type

Page 8

INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri- mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

WARNING: Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annu- ally by a professional service person. More frequent cleaning may be required due to exces- sive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.

WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creo- sote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and distribute soot within the house. Inspect chim- ney flue and firebox for damage. If damaged, repair flue before operating heater.

WARNING: Seal any fresh air vents or ash clean-out doors located on floor or wall of fire- place. If not, drafting may cause pilot outage or sooting. Use a heat-resistant sealant. Do not seal chimney flue damper.

WARNING: Never install the heater

in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the firebox opening

in high traffic areas

in windy or drafty areas

CAUTION: This heater cre- ates warm air currents. These currents move heat to wall sur- faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning flu- ids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, page 5.

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install fireplace. Call dealer where you bought fireplace for proper type fireplace.

WARNING: This appliance is equipped for (natural or pro- pane/LP) gas. Field conversion is not permitted.

8

www.desatech.com

113183-01A

Image 8
Contents What to do if YOU Smell GAS Thermostat Models CDR3924NT and CDR3924PTTable of Contents Safety Information Local Codes Product Features Product IdentificationAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Confined and Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Check GAS TypeInstallation and Clearances for VENT-FREE Operation RearWidth 20 1/4Determining Minimum Mantel Clearance When Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installation Items NeededConnecting to GAS Supply External Regulator With Vent Pointing DownChecking GAS Connections Propane/LP FromNatural From Gas Test Pressures In Excess Of 1/2 Psig 3.5 kPaInstalling Logs Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaAttaching Grate to Base Assembly Adding Lava RockLighting Instructions For Your Safety Read Before LightingOperating Heater Thermostat Control Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Technical Service Inspecting BurnersPilot Flame Pattern Burner Flame PatternsLogs Cleaning MaintenanceBurner Injector Holders and Pilot AIR Inlet Holes Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Cold Minute Air in gas line Operate burners until air is Gas leak. See Warning Optional Positioning Thermostat Sensing Bulb For Masonry and FACTORY- Built Metal FireplaceSpecifications Replacement PartsService Hints AccessoriesIllustrated Parts Breakdown Models CDR3924PT and CDR3924NTParts List Limited Warranty Comfort Glow VENT-FREE GAS LOG Heaters Warranty InformationKeep this Warranty

CDR3924PT specifications

Desa CDR3924PT is an advanced digital control thermostat designed for precise temperature management in residential and commercial settings. Its sleek design and intuitive interface make it a popular choice among homeowners and professionals alike, contributing to enhanced comfort and energy efficiency in various environments.

One of the standout features of the CDR3924PT is its programmable functionality. Users can set different temperature schedules for weekdays and weekends, allowing for tailored climate control to match occupancy patterns. This flexibility can lead to significant energy savings, as the thermostat can automatically adjust heating and cooling based on user preferences and habits.

The unit is equipped with a high-resolution LCD display, offering clear visibility of current temperature settings and system status. Additionally, it provides real-time feedback on energy consumption, allowing users to monitor and adjust usage to optimize efficiency. The intuitive touch controls simplify navigation through the various settings, ensuring that users can easily customize their environment.

Integration with smart home technology is another key characteristic of the CDR3924PT. It is compatible with various home automation systems, enabling users to control their heating and cooling remotely via smartphone apps. This connectivity ensures that users can adjust settings from anywhere, giving them the ability to prepare their home environment before arriving or to fine-tune adjustments on the go.

The CDR3924PT utilizes advanced sensor technology to maintain accurate temperature control. It continuously measures ambient conditions, making real-time adjustments to ensure consistent comfort levels. The thermostat’s adaptive learning capabilities also allow it to learn user preferences over time, further enhancing its ability to maintain optimal conditions with minimal energy consumption.

For safety and convenience, the thermostat features a user-friendly installation process along with compatibility with various HVAC systems. It includes built-in safety protocols that prevent overheating or unwanted system failures, ensuring reliable operation over time.

In summary, the Desa CDR3924PT stands out in the market for its programmable features, smart home integration, and advanced sensor technology, making it a top choice for those seeking efficient and effective temperature management solutions. Whether for residential use or commercial applications, its reliable performance and user-friendly design make it a vital component in modern climate control systems.