Desa PCVDR24 RGA installation manual Vented Natural GAS Logs, Safety Information

Page 2

VENTED NATURAL GAS LOGS

SAFETY

INFORMATION

WARNINGS

WARNING: Keep flue open when operating unit.

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper- ate, or service this log set. Im- proper use of this log set can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, or nausea. If you have these signs, the log set may not be working properly. Get fresh air at once! Have log set serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Natural Gas: Natural gas is odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this log set.

WARNING: Any change to this log set or its controls can be dangerous.

1.This appliance, as supplied, is only for use with the type of gas indicated on the rating plate. This appliance is con- vertible for use with propane/LP, using the GA9050 or GA9150 pilot kit.

2.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

3.Never install the log set

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the log set

in high traffic areas

in windy or drafty areas

4.Before installing in a solid fuel burn- ing fireplace, the chimney flue and fire- box must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. Inspect chimney flue for damage.

5.You must operate this log set with a fire- place screen in place. Make sure fireplace screen is closed before running log set.

6.This log set is designed to be smoke- less. If logs ever appear to smoke, turn off appliance and call a qualified ser- vice person. Note: During initial op- eration, slight smoking could occur due to log curing and the burning of manu- facturing residues.You may wish to add more ventilation by opening a window.

7.To reduce the creation of soot, follow the instructions in Cleaning and Main- tenance, page 18.

8.Do not allow fans to blow directly into the fireplace. Avoid any drafts that al- ter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can increase sooting.

9.Do not use a blower insert, heat ex- changer insert, or other accessory not approved for use with this log set.

10.This log set needs fresh, outside air ven- tilation to run properly. See Air for Combustion and Ventilation, pages 4 through 6.

11.Do not run log set

where flammable liquids or vapors are used or stored

under dusty conditions

12.Do not burn solid fuel in the fireplace after installing the log set. Do not use this log set to cook food or burn paper or other objects.

13.Log set becomes very hot when in use. Keep children and adults away from hot surface to avoid burns or clothing igni- tion. Log set will remain hot for a time after shut-down. Allow surface to cool before touching.

14.Carefully supervise young children when they are in the room with log set.

15.Do not use appliance if any part has been exposed to or under water. Immediately call a qualified service technician to in- spect the room appliance and to replace any part of the control system (if using GA9050 or GA9150) and any gas con- trol which has been under water.

16.To help prevent breakage, new logs must be broken-in (see Curing logs page 12).

17.Turn log set off and let cool before ser- vicing, installing, or repairing. Only a qualified service person should install, service, or repair log set.

2

901747

Image 2
Contents Approved OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Safety Information Vented Natural GAS LogsRemote Control Ready Millivolt Safety VALVE/ Pilot KIT Local Codes Unpacking Optional Product FeaturesON/OFF Safety VALVE/ Pilot KIT and PROPANE/LP Conversion Remote Control AccessoriesUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Appliance Location Building Ventilation AIRVentilation Air From Inside Ventilation Air From OutdoorsVenting Specifications for Installation InstallationFlue Opening Specifications Installing Damper ClampPressure Testing Gas Supply Piping System Connecting to GAS SupplyInstallation Items Needed Checking GAS ConnectionsInstallation and Gas Connection Hearth KIT Assembly and InstallationKit Assembly Natural Gas InstallationChanging Pilot Orifice Propane/LP Gas ConversionBurner Inlet Fitting Adding PAN Material Testing Burner for LeaksInstalling the Grate and Logs Operating Appliance Shutting Off Burner Only pilot stays lit TroubleshootingTo Turn OFF GAS To Appliance Clean pilot see Cleaning and Mainte Top Gas leak. See Warning statement atIllustrated Parts Breakdown Model PCVDR24Parts List KEY Part Number Description QTYReplacement Parts Cleaning and MaintenanceAccessories Parts Centrals FBDKeep this Warranty International

PCVDR24 RGA specifications

Desa PCVDR24 RGA is a cutting-edge device designed to enhance temperature management in residential and commercial spaces. This innovative product stands out in the market thanks to its advanced technology and user-friendly features.

At its core, the PCVDR24 RGA offers precise temperature control, allowing users to maintain their desired comfort levels efficiently. It uses a highly responsive digital thermostat, which ensures accurate readings and minimal temperature fluctuations. This feature not only contributes to user comfort but also promotes energy efficiency, as the system avoids unnecessary heating or cooling cycles.

One of the key features of the Desa PCVDR24 RGA is its robust construction. Designed for durability, this unit is built to withstand varying environmental conditions, making it suitable for both indoor and outdoor applications. The materials used in its construction resist rust and corrosion, ensuring a long lifespan even in harsh climates.

The PCVDR24 RGA also employs advanced airflow technology, which facilitates even distribution of heated or cooled air. This ensures that every corner of the room reaches the desired temperature without hot or cold spots, significantly enhancing comfort levels for occupants.

Furthermore, the device is equipped with programmable settings, allowing users to tailor temperature schedules based on their daily routines. This smart feature not only enhances user convenience but also contributes to energy savings, as homeowners and business operators can adjust the heating and cooling cycles to operate according to their specific needs.

Additionally, the Desa PCVDR24 RGA comes with a built-in safety mechanism designed to prevent overheating. This greatly reduces the risk of potential accidents, ensuring a safe environment for all users.

In terms of energy efficiency, the PCVDR24 RGA is designed to meet rigorous industry standards, making it an environmentally friendly choice. Users can expect a reduction in energy bills due to its efficient operation, which is increasingly important in today’s eco-conscious society.

In summary, the Desa PCVDR24 RGA combines advanced technology, robust construction, and user-friendly features to provide a reliable solution for temperature management. Its precise control, even airflow distribution, programmable settings, and safety features make it an attractive option for anyone looking to improve comfort and energy efficiency in their space.