Desa PCVDR24 RGA installation manual Operating Appliance

Page 12

VENTED NATURAL GAS LOGS

OPERATING

APPLIANCE

FOR YOUR SAFETY

READ BEFORE

LIGHTING

WARNING: Keep flue open when operating unit.

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information, above.

2.Turn the gas shut-off valve to OFF.

3.Wait five (5) minutes to clear out any gas. If you then smell gas STOP! Fol- low the safety information above. If you don't smell gas, go on to the next step.

4.Light a match and lay it on top of the pan material about 2" from the end of the supply side of the pan

5.Slowly turn the gas shut-off valve ON until the burner ignites. If the burner does not ignite within 10 seconds with the match burning, turn the shut-off valve OFF and repeat steps 1 through 4 again.

GAS SHUT-OFF

VALVE OPERATION

Flame Adjustment

1.Adjust the flame ON/OFF by turn-

ing the gas shut-off valve counter-

clockwise to open or clock-

wise to close, as necessary.

Shutting Off Appliance

1.Turn gas shut-off valve clockwise to the OFF position.

CURING LOGS

During the 2-3 hour appliance break-in period, you may detect an odor from the appliance as the various paints and com- pounds used in the manufacturing of this log set cure. This is a normal and tempo- rary situation that is not cause for alarm. However, you may want to provide extra ventilation to the room during this time. To ensure proper curing of the logs:

Ignite a 2" flame and maintain it for 1 hour.

Burn the logs in consecutive 1 hour pe- riods raising the flame an additional 2" to full flame height for a total of three hours.

OPERATING

INSTRUCTIONS FOR

GA9050

Note: Operation instructions for GA9150 Remote Ready Valve/Pilot Kit will be included with the kit.

1.STOP! Read the safety information, column one, this page.

2.Make sure manual shutoff valve is fully open.

3.Press in and turn control knob clock-

wise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas around log set and near floor. If you smell gas, STOP! See Safety Information, page 2 and Air For Combustion And Venti- lation, pages 4 through 6. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise to the PILOT position and press in. Keep control knob pressed in for five (5) seconds.

Note: You may be running this log set for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 sec- onds. This will allow air to bleed from the gas system.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the rear of the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, con- tact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.

8.Turn control knob counterclockwise to the ON position. Burner should light. If burner does not light, call a qualified service person.

Control Knob

Ignitor

Pilot

 

 

ON

OFF

 

FROM "PILOT" POSITION

On

SLIGHT PUSH TO

Off

 

PULL PUSH

 

 

TURN OFF

 

ON OFF FROM "PILOT" POSITION

SLIGHT PUSH TO TURN OFF PULL PUSH

TURN OFF PULL PUSH

ON OFF FROM "PILOT" POSITION SLIGHT PUSH TO

Figure 22 - Ignitor and Control Knob

 

 

 

Thermo-

Pilot

 

 

couple

Figure 23 - Thermocouple and Pilot

12

901747

Image 12
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASApproved Safety Information Vented Natural GAS LogsLocal Codes Unpacking Optional Product Features ON/OFF Safety VALVE/ Pilot KIT and PROPANE/LP ConversionRemote Control Ready Millivolt Safety VALVE/ Pilot KIT Remote Control AccessoriesAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Appliance LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From InsideBuilding Ventilation Air From OutdoorsInstallation Flue Opening SpecificationsVenting Specifications for Installation Installing Damper ClampConnecting to GAS Supply Installation Items NeededPressure Testing Gas Supply Piping System Checking GAS ConnectionsHearth KIT Assembly and Installation Kit AssemblyInstallation and Gas Connection Natural Gas InstallationPropane/LP Gas Conversion Burner Inlet FittingChanging Pilot Orifice Testing Burner for Leaks Installing the Grate and LogsAdding PAN Material Operating Appliance Troubleshooting To Turn OFF GAS To ApplianceShutting Off Burner Only pilot stays lit Clean pilot see Cleaning and Mainte Top Gas leak. See Warning statement atIllustrated Parts Breakdown Model PCVDR24Parts List KEY Part Number Description QTYCleaning and Maintenance AccessoriesReplacement Parts Parts Centrals FBDKeep this Warranty International

PCVDR24 RGA specifications

Desa PCVDR24 RGA is a cutting-edge device designed to enhance temperature management in residential and commercial spaces. This innovative product stands out in the market thanks to its advanced technology and user-friendly features.

At its core, the PCVDR24 RGA offers precise temperature control, allowing users to maintain their desired comfort levels efficiently. It uses a highly responsive digital thermostat, which ensures accurate readings and minimal temperature fluctuations. This feature not only contributes to user comfort but also promotes energy efficiency, as the system avoids unnecessary heating or cooling cycles.

One of the key features of the Desa PCVDR24 RGA is its robust construction. Designed for durability, this unit is built to withstand varying environmental conditions, making it suitable for both indoor and outdoor applications. The materials used in its construction resist rust and corrosion, ensuring a long lifespan even in harsh climates.

The PCVDR24 RGA also employs advanced airflow technology, which facilitates even distribution of heated or cooled air. This ensures that every corner of the room reaches the desired temperature without hot or cold spots, significantly enhancing comfort levels for occupants.

Furthermore, the device is equipped with programmable settings, allowing users to tailor temperature schedules based on their daily routines. This smart feature not only enhances user convenience but also contributes to energy savings, as homeowners and business operators can adjust the heating and cooling cycles to operate according to their specific needs.

Additionally, the Desa PCVDR24 RGA comes with a built-in safety mechanism designed to prevent overheating. This greatly reduces the risk of potential accidents, ensuring a safe environment for all users.

In terms of energy efficiency, the PCVDR24 RGA is designed to meet rigorous industry standards, making it an environmentally friendly choice. Users can expect a reduction in energy bills due to its efficient operation, which is increasingly important in today’s eco-conscious society.

In summary, the Desa PCVDR24 RGA combines advanced technology, robust construction, and user-friendly features to provide a reliable solution for temperature management. Its precise control, even airflow distribution, programmable settings, and safety features make it an attractive option for anyone looking to improve comfort and energy efficiency in their space.