AquaStar 125FX LP, 125FX NG specifications Combustion AIR Requirements, Clearances

Page 5

COMBUSTION AIR REQUIREMENTS

The AquaStar water heater holds cold water in its copper heat exchanger and brass water valve when not in use. Because of this, any cold air that comes in through the unit’s vent pipe is capable of freezing these components. This Installation Manual specifies the vent length requirements and the amount of combustion air required for this unit. When all requirements are followed, the unit will operate properly and safely. However, there may still be a risk of freezing due to negative draft if all the combustion appliances in the area are not being supplied with a sufficient amount of make-up air. A wood stove or furnace can rob the make-up air in the AquaStar’s vent pipe, leaving the cold infiltrating air capable of freezing the cold water in the AquaStar heat exchanger. To prevent this the FXHOOD horizontal vent terminator, which is supplied separately with the water heater, needs to be installed on the end of the horizontal vent run (see page 7). The FXHOOD is a CSA approved vent terminator for the Aquastar 125FX and has a built in back draft flapper.

Observe the following instructions concerning combustion air.

Appliances located in unconfined spaces:

a)An unconfined space is one whose volume is greater than 50 cubic feet per 1000 Btu per hour of the combined rating of all appliances installed in the space. That would be 6500 cubic feet for the AquaStar 125FX alone.

b)In unconfined spaces in buildings of conventional frame, masonry, or metal construction, infiltration is normally adequate to provide air for combustion, ventilation, and dilution of flue gasses.

Appliances located in confined spaces: The confined space must be provided with two permanent openings, one commencing within 12 inches of the top and one commencing within 12 inches of the bottom of the enclosure. Each opening must have a minimum free area of one square inch per:

1000 Btu/hr if all air is taken from inside the building.

2000 Btu/hr if all air is taken from the outside by horizontal ducts.

4000 Btu/hr if all air is taken from the outside by direct openings or vertical ducts.

Or the confined space must be provided with one permanent opening or duct that is within 12 inches of the ceiling of the enclosure. This opening must have a minimum free area of one square inch per:

3000 Btu/hr if all air is taken from the outside by a direct opening or vertical duct.

Louvers, grills and screens have a blocking effect. If the effective free area is not known, assume it is 20 % to 25% of the total opening for wood louvers and 60 % to 75% for metal louvers. Refer to the National Fuel Gas Code for complete information. In buildings of tight construction all air should be taken from outside.

This product is not approved for manufactured homes (mobile home), recreational vehicles (RV) or boats. Reference ANSI Z21.10.3.

This product is neither designed or approved for outside installations.

CLEARANCES

The Aquastar 125FX is design certified for installation on a combustible wall and for installation in an alcove or closet with the minimum clearances to combustible and non - combustible construction listed below

A.Top 12 inches (305 mm)

B.Front 4 inches (102 mm)

C.Back 0 inches*

D.Sides 4 inch (102mm)

E.Bottom 12 inches (305 mm)

Air Vents

 

 

* On a combustible wall surface the unit should be mounted

 

125FX

away from the wall to provide adequate clearance of the

(10 ¾ X 10 ¾ in. each)

 

 

 

vent pipe. Clearance from the vent pipe is dependent upon the clearance rating of the venting material used. See VENTING section.

125FX Air Vents

(5 ½ X 5 ½ in. each)

6 720 606 601

5

Image 5
Contents What to do if YOU Smell GAS For Your SafetyTable of Contents Unpacking the Aquastar Heater FeaturesTOP a Front B Back Sides Floor C Vent Diameter Front View Side ViewGeneral Rules to Follow For Safe Operation Proper Location for Installing Your HeaterClearances Combustion AIR RequirementsIncandescent Particle Tray Illustration Mounting InstallationFeet 4.6 m with two VentingHorizontal Side Wall Soffit GAS Line Sizing GAS ConnectionsFor LP GAS GAS PIPING, ConnectionsGAS Line Sizing For Natural GAS Water Connections Water valve and water connectors, top viewElectrical Connections Flue gas safety deviceLighting and Operating Instructions For Your Safety Read Before Operating Your HOT Water HeaterTemperature Adjustment Knob No Spark AT the Pilot Microswitch adjustmentPilot Sparks Continuously with no Water Running FAN Circulates When HOT Water is Shut OFF Diagram of AquaStar 125FX Interior Components Diagram and Parts List Interior Components Diagram Parts List 125FX Flow chart of Aquastar 125 FX Limited Warranty Maintenance Table see page15

125FX NG, 125FX LP specifications

The AquaStar 125FX NG and 125FX LP are two remarkable models in the world of high-efficiency heaters. Designed for optimal performance in residential settings, these devices cater to diverse needs with their advanced technology and user-friendly features.

The AquaStar 125FX NG model operates using natural gas, while the 125FX LP utilizes liquid propane. This versatility allows users to choose the most suitable fuel type for their home setup. Both models boast an impressive energy efficiency rating, ensuring minimal energy waste while delivering reliable hot water on demand. This makes them not only cost-effective but also an eco-friendly choice for homeowners looking to reduce their carbon footprint.

One of the standout features of the AquaStar 125FX series is its compact design, which makes it ideal for installations in small spaces. With a sleek and modern appearance, it can easily blend into various interior aesthetics without occupying excessive room. The units are also relatively lightweight, facilitating a simple installation process.

In terms of performance, both the NG and LP models are equipped with a powerful BTU input that guarantees quick heating capabilities. They can provide ample hot water for multiple applications simultaneously, such as showers and dishwashing, making them perfect for busy households. Furthermore, the AquaStar 125FX units utilize advanced burner technology that ensures efficient combustion, resulting in a constant supply of hot water without fluctuations in temperature.

Safety is paramount in the design of the AquaStar 125FX series. Each heater is equipped with comprehensive safety features, including built-in vents for proper exhaust and a flame failure device that shuts the heater off if the flame goes out unexpectedly.

The control panel on both models is intuitive, allowing users to easily adjust the water temperature and monitor the unit's performance. Additionally, the AquaStar 125FX series is designed for longevity, with corrosion-resistant materials that withstand the rigors of daily use.

In summary, the AquaStar 125FX NG and 125FX LP are perfect examples of modern, efficient water heating technology. With their compact design, rapid heating capabilities, and robust safety features, these models present an excellent choice for any home looking to enhance its hot water supply while maintaining efficiency and environmental responsibility.