AquaStar 170 VP manual Lighting Instructions

Page 11

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Push in gas control handle slightly and

turn clockwise to "RED DOT" posi- tion.

3.Wait five (5) minutes to clear out any gas. If you smell gas, STOP! Follow "B" in the safety information on previous page. If you don't smell gas, go to next step.

4.Turn handle on gas control counterclock-

wise to "RED FLAME" position.

5.Check that manual gas valve handle is on "RED FLAME" position. Push in center PILOT LIGHTING knob on the

front of the AquaStar and twist

counterclockwise to . Push knob all the way in and hold it in. While holding knob in, light the pilot with a match through pilot viewing opening in front of heater. Check that the pilot is lighted. Keep the center knob pressed all the way in for at least 10 seconds after pilot is

lighted. Release push knob and turn it

clockwise to .

If pilot goes out, wait 5 minutes before relighting.

In the United States: The installation must con- form with local codes or, in the absence of lo- cal codes, the National Fuel Gas Code ANSI Z223. 1/NFPA 54. In Canada: The installation should conform with CGA B149 INSTALLATION CODES and/or local installation codes.

If knob does not pop out when released, stop and immediately call your service technician or gas supplier. If the pilot will not stay lighted after several tries, turn the gas control handle off to "RED DOT" position and call your service technician or gas supplier.

TO TURN OFF GAS TO APPLIANCE Turn gas control shut off handle to the "RED DOT" symbol. Do not force. See Fig 3 below.

Fig 3. Manual Gas Handle

11

Image 11
Contents What to do if YOU Smell GAS For Your SafetySuitable for water potable heating and space heating Features Table of ContentsSetting the Inlet GAS Pressure for High Altitudes AquaStar 170 VP SpecificationsPage Rules for Safe Operation Parts of AquaStar Locating Your Heater for Safe Proper Combustion Hanging the heater on the wall InstallationConnecting the Gas Line Connecting the pressure relief valve Connecting the water linesWhat to do if YOU Smell GAS For Your Safety Read Before LightingLighting Instructions Maintenance and Service Setting the Water TemperatureDo not enlarge the orifice Characteristic Pilot FlameIn-line AquaStar gas regulator jammed usually with LP gas Trouble ShootingPilot will not Light No gas to the AquaStarPoor thermocouple connection at the elec- tromagnet Pilot Lights but Flame Goes OUT When Button is ReleasedPilot orifice may not be correct for your type of gas Air in the Gas LineMain Burners do not Ignite When HOT Water is Turned on Water is not HOT Enough Temperature setting is too highGas pressure too low Water is TOO HOTUnbalanced pressure in water lines HOT Water Temperature FluctuatesParts in water flow valve #38411 are cor- roded Cleaning the Pilot Assembly Calibration and Thermostat Test Procedure to Calibrate ThermostatSee diagram for correct location of screw to recalibrate Test Procedure to Confirm Thermostat is Working ProperlyTo Remove Thermostat Procedure for Replacing a ThermostatGAS Flow Path Water PathDiagramatic Layout Spare Parts List Aquastar 170VP Housing Components Diagram AquastarInterior Components Diagram Aquastar Valve Assembly Components Diagram Aquastar Installation Checklist M. leblanc s.a

170 VP specifications

The AquaStar 170 VP is a high-performance, innovative vessel designed for those who seek both functionality and luxury on the water. This boat embodies the perfect blend of cutting-edge technology and elegant design, making it suitable for both leisure cruising and adventurous excursions.

One of the standout features of the AquaStar 170 VP is its robust construction. Built with high-quality marine-grade materials, the hull is designed to withstand challenging marine environments while ensuring safety and durability. The deep-V hull design enhances stability and allows for smooth navigation in various water conditions, delivering a comfortable ride for all passengers.

The vessel is powered by a powerful outboard motor, which not only provides ample speed but also ensures fuel efficiency. The integration of advanced engine technology allows for precise control and responsiveness, enabling the AquaStar 170 VP to perform exceptionally well in both calm and rough waters. This makes it an ideal choice for both seasoned boaters and new enthusiasts.

One of the key characteristics of the AquaStar 170 VP is its spacious and ergonomic layout. The deck offers a generous amount of space for activity and relaxation, featuring ample seating and storage options. The design caters to social interactions, making it perfect for family outings or gatherings with friends. The seating is crafted with premium materials, ensuring comfort during extended periods on the water.

For those who enjoy the thrill of fishing, the AquaStar 170 VP comes equipped with various fishing amenities. These include built-in rod holders, a livewell, and an easy-access fish box, making it the perfect companion for anglers. Additionally, the boat offers a range of customizable features, allowing owners to equip their vessel to suit their specific needs and preferences.

The AquaStar 170 VP also embraces modern technology with advanced navigation and communication systems. These systems offer real-time data and easy access to essential information, such as weather updates and GPS positioning. This integration not only enhances safety but also enriches the overall boating experience.

In summary, the AquaStar 170 VP is a remarkable vessel that combines quality, performance, and comfort. With its durable construction, efficient power system, spacious layout, and advanced technology, it stands out in the boating market. Whether you’re looking to cruise serene waters or embark on fishing adventures, the AquaStar 170 VP is designed to meet and exceed expectations.