AquaStar 170 VP manual Rules for Safe Operation

Page 5

RULES FOR SAFE OPERATION

1.You should follow these instructions when you install your heater.

In the United States: The installation must con- form with local codes or, in the absence of lo- cal codes, the National Fuel Gas Code ANSI Z223.1/NFPA 54.

In Canada: The installation should conform with CGA B149.(1,2) INSTALLATION CODES and/or local installation codes.

2.Carefully plan where you install the heater. Correct combustion air supply and flue pipe installation are very important. If the gas appliance is not installed correctly, fatal

accidents can result from lack of air, carbon monoxide poisoning or fire.

3.The place where you install the heater must have enough ventilation. The National Fire Codes do not allow water heater installation in bathrooms, bedrooms or any occupied rooms normally kept closed. See the section on Pages 7-8 on Locating the Heater.

4.You must vent your heater. See section on Vent Pipe Connection, Page 10, paragraph 6 and Venting Guide on page 27.

5.The appliance and its individual shutoff valve must be disconnected from the gas supply pip- ing system during any pressure testing of that system at pressures in excess of 1/2 psig (3.5kPa).

The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure test- ing of the gas supply piping system at test pres- sures equal to or less than 1/2 psig (3.5kPa). The appliance and its gas connection must be leak tested before placing the appliance in op- eration

6.Keep water heater area clear and free from combustibles and flammable liquids. Do not locate the heater over any material which might burn, such as carpet.

7.Correct gas pressure is critical for the opti- mum operation of this heater (see specifications on page 3). Gas piping must be sized to pro- vide the required pressure at the maximum output of the heater. Check with your local gas supplier, and see gas line size requirements on page 27.

8.As a precaution, shut off your heater if you plan to be away for several days.

9.Should overheating occur and the gas supply fail to shut off, turn off the manual gas control valve to the appliance.

10.See instructions on setting the water tem- perature, page 12.

11.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

5

Image 5
Contents What to do if YOU Smell GAS For Your SafetySuitable for water potable heating and space heating Features Table of ContentsSetting the Inlet GAS Pressure for High Altitudes AquaStar 170 VP SpecificationsPage Rules for Safe Operation Parts of AquaStar Locating Your Heater for Safe Proper Combustion Hanging the heater on the wall InstallationConnecting the Gas Line Connecting the pressure relief valve Connecting the water linesWhat to do if YOU Smell GAS For Your Safety Read Before LightingLighting Instructions Maintenance and Service Setting the Water TemperatureDo not enlarge the orifice Characteristic Pilot FlamePilot will not Light Trouble ShootingNo gas to the AquaStar In-line AquaStar gas regulator jammed usually with LP gasPilot orifice may not be correct for your type of gas Pilot Lights but Flame Goes OUT When Button is ReleasedAir in the Gas Line Poor thermocouple connection at the elec- tromagnetMain Burners do not Ignite When HOT Water is Turned on Gas pressure too low Temperature setting is too highWater is TOO HOT Water is not HOT EnoughUnbalanced pressure in water lines HOT Water Temperature FluctuatesParts in water flow valve #38411 are cor- roded Cleaning the Pilot Assembly See diagram for correct location of screw to recalibrate Procedure to Calibrate ThermostatTest Procedure to Confirm Thermostat is Working Properly Calibration and Thermostat TestTo Remove Thermostat Procedure for Replacing a ThermostatGAS Flow Path Water PathDiagramatic Layout Spare Parts List Aquastar 170VP Housing Components Diagram AquastarInterior Components Diagram Aquastar Valve Assembly Components Diagram Aquastar Installation Checklist M. leblanc s.a

170 VP specifications

The AquaStar 170 VP is a high-performance, innovative vessel designed for those who seek both functionality and luxury on the water. This boat embodies the perfect blend of cutting-edge technology and elegant design, making it suitable for both leisure cruising and adventurous excursions.

One of the standout features of the AquaStar 170 VP is its robust construction. Built with high-quality marine-grade materials, the hull is designed to withstand challenging marine environments while ensuring safety and durability. The deep-V hull design enhances stability and allows for smooth navigation in various water conditions, delivering a comfortable ride for all passengers.

The vessel is powered by a powerful outboard motor, which not only provides ample speed but also ensures fuel efficiency. The integration of advanced engine technology allows for precise control and responsiveness, enabling the AquaStar 170 VP to perform exceptionally well in both calm and rough waters. This makes it an ideal choice for both seasoned boaters and new enthusiasts.

One of the key characteristics of the AquaStar 170 VP is its spacious and ergonomic layout. The deck offers a generous amount of space for activity and relaxation, featuring ample seating and storage options. The design caters to social interactions, making it perfect for family outings or gatherings with friends. The seating is crafted with premium materials, ensuring comfort during extended periods on the water.

For those who enjoy the thrill of fishing, the AquaStar 170 VP comes equipped with various fishing amenities. These include built-in rod holders, a livewell, and an easy-access fish box, making it the perfect companion for anglers. Additionally, the boat offers a range of customizable features, allowing owners to equip their vessel to suit their specific needs and preferences.

The AquaStar 170 VP also embraces modern technology with advanced navigation and communication systems. These systems offer real-time data and easy access to essential information, such as weather updates and GPS positioning. This integration not only enhances safety but also enriches the overall boating experience.

In summary, the AquaStar 170 VP is a remarkable vessel that combines quality, performance, and comfort. With its durable construction, efficient power system, spacious layout, and advanced technology, it stands out in the boating market. Whether you’re looking to cruise serene waters or embark on fishing adventures, the AquaStar 170 VP is designed to meet and exceed expectations.