Bradford-White Corp 238-37281-00R AIR Intake Must be AT Least 12 30.5cm Above the Ground Level

Page 9

Combustion air supply continued-

1.After selecting the proper location for the water heater, cut a 4” (10.2cm) diameter hole through the floor and all other layers of flooring and sheathing directly beneath the front center of the water heater.

2.Insert the air intake into the 4” (10.2cm) diameter hole and fasten to the floor with the screws provided.

3.Adjust the air intake so the lower tube extends below the underside sheathing and secure with the screws provided. THE BOTTOM OF THE

AIR INTAKE MUST BE AT LEAST 12” (30.5cm) ABOVE THE GROUND LEVEL.

4.Seal the openings around the air intake and underside sheathing to resist the entrance of rodents.

5.Position the water heater so it is centered above the air intake. (Note:

The water heater should also be centered with the openings in the roof and ceiling to allow for correct assembly of the roof jack to the flue tube.)

The water heater is to be secured in place using the supplied sheet metal strapping and screws. Fasten the base of the water heater to the floor using the screws provided. The perforated metal strapping must be fastened to the top of the water heater and to the adjacent walls with the screws provided. (See Figure 2)

Venting

WARNING

The vent system must be installed properly. Failure to properly install the vent system could result in property damage, personal injury, or death.

Make certain the flue baffle is in place and centered in flue tube. Cut a 7 1/4 inch (18.5cm) diameter hole in the ceiling and roof directly above the flue of the water heater. Center the water heater beneath the 7 1/4 (18.5cm) inch diameter holes in the roof and ceiling for proper alignment of the flue tube and roof jack vent. Apply non-hardening mastic on the roof, around the previously cut hole, to form a weather seal with the flashing of the gas vent roof jack assembly. Note: Only the roof jacks listed in Figure 2 can be used on this water heater. Insert the 3” (7.62 cm) vent connector extension (shipped telescoped) into the gas vent roof jack assembly and down onto the flue pipe extruding from the top of the water heater. Fasten the 3” (7.62 cm) vent connector to the flue pipe using the 3” (7.62 cm) clamp provided. After all connections are made, apply a bead of silicone (supplied with vent kit) to all vent seams and connections above the flue pipe (some kits may contain silicone bands to seal vent joints).

9

Image 9
Contents GAS Water Heater For Your SafetyCongratulations Table of Contents General Information Locating the Water Heater InstallationDo not Operate Appliance Until Leakage is Corrected Minimum Clearances Installation AIR Intake Must be AT Least 12 30.5cm Above the Ground Level Installation Venting Being Certain IT is Filled with Water Water Connections Open Flame for Testing Gas Conversion Instructions Gas Conversion Instructions To Fill the Water Heater General OperationLighting and Shutdown Instructions Thermostat Adjustment Maintenance Maintenance Maintenance Typical Installation Part Name & Description GAS Fired Manufactured Home Mobile Home Parts ListSteel Burner Assembly

238-37281-00R specifications

Bradford-White Corp has long been recognized as a leader in the water heating industry, and the 238-37281-00R is a prime example of their commitment to quality and innovation. This specific model is designed for residential applications, offering efficient performance tailored to meet the needs of modern households.

One of the standout features of the 238-37281-00R is its Energy Star rating, which signifies its superior energy efficiency compared to traditional water heaters. This translates to reduced energy bills and a lesser environmental footprint, appealing to energy-conscious consumers looking to save on costs while still enjoying reliable hot water access.

The unit operates with advanced technology that enhances its overall performance. It is equipped with a vortex combustion system that improves efficiency by ensuring complete combustion, minimizing wasted energy. This technology also contributes to quieter operation and increased safety by reducing the risk of gas leaks.

In terms of design, the Bradford-White 238-37281-00R is built with durability in mind. It features a robust tank made from high-grade materials that resist corrosion, ensuring a longer lifespan. The insulation used in the tank is also top-notch, reducing heat loss and improving energy retention, which ultimately leads to increased efficiency.

Installation is straightforward, thanks to the compact design of the unit. It offers versatility in terms of placement, making it suitable for a variety of home configurations. Homeowners can install it in tight spaces without compromising on performance or efficiency.

Another important characteristic of this model is its maintenance-friendly design. Bradford-White provides access to critical components for easy servicing, which can prolong the life of the water heater and maintain performance over time.

Additionally, the 238-37281-00R includes advanced safety features, such as a temperature and pressure relief valve, and an integrated control system that monitors and responds to any potential issues, giving homeowners peace of mind.

Overall, the Bradford-White Corp 238-37281-00R stands out due to its combination of efficiency, durability, and safety. It embodies the company's dedication to delivering high-quality water heating solutions that cater to the needs of today's consumers. With its advanced technologies and user-friendly design, it represents an excellent investment for anyone in search of a reliable water heating option.