Bosch Appliances 125B LPS, 125B NGS Interior Components Diagram Parts List 125BS

Page 19

Fig. 11

INTERIOR COMPONENTS DIAGRAM

AND PARTS LIST 125BS

1

Cover

8 705 421 033

 

2

Cap cover

8 703 304 011

 

3

Water connection gasket

8 710 103 043

 

4

Draft divertor

8 705 505 354

 

5

Heat exchanger

8 705 406 189

 

6

Hot water pipe

8 700 705 431

 

7

Cold water pipe

8 700 705 294

 

8

Heat exchanger washer

8 710 103 045

 

9

Overheat sensor (ECO)

8 707 206 017

 

10

Main burner assembly

8 708 120 296

LP

 

Main burner assembly

8 708 120 298

NG

11

Pilot burner assembly

8 718 105 051

 

11a

Pilot filter screen

8 700 507 055

 

12

Piezo electrode

8 708 107 002

 

13

Pilot orifice

8 708 200 005

NG

 

Pilot orifice

8 748 200 173

LP

14

Pilot Tube

8 710 707 166

 

15

Thermocouple

8 747 202 083

 

16

Burner assembly washer

8 710 103 060

 

17

Gas valve

8 707 011 467

LP

 

Gas valve

8 707 011 469

NG

18

Gas supply pipe

8 700 705 464

 

19

Electromagnet

8 747 201 094

 

20

Electromagnet washer

8 700 103 144

 

21

Gas filter

8 700 507 051

 

22

Thermocable

8 747 202 078

 

23

Thermostat

8 707 206 039

 

24

O ring Thermostat

8 700 205 101

 

25

O ring Thermostat

8 700 205 041

 

26

Water valve assembly

8 707 002 393

 

27

Pushrod

8 703 406 204

 

28

Water valve diaphragm

8 700 503 050

 

29

Slow ignition valve

8 708 503 062

 

30

Water valve setting screw

8 703 404 092

 

31

O ring setting screw

8 700 205 050

 

32

Water valve venturi

8 708 205 235

 

33

Water valve piston assembly

8 708 500 230

 

34

Water inlet filter

8 700 507 059

 

35

Water elbow fitting

8 700 703 114

 

36

Water valve set screw

8 703 401 051

 

6 720 606 518

19

Image 19
Contents Table of Contents For Your SafetyUnpacking the Aquastar Heater FeaturesRequired Natural Gas Pressure at inlet tap Model 125BS Front View Side ViewTOP a Front B Back Sides Floor C Vent Diameter General Rules to Follow For Safe Operation Proper Location for Installing Your HeaterClearances Combustion AIR RequirementsAquastar 125 B S is design certified for mounting on a wall Mounting InstallationFigure a VentingFigure C 720 606 Masonry Chimneys6 Adaptor Used on High Altitude Vent Adaptor for High Altitude InstallationsFor LP GAS GAS Line Sizing For Natural GASAbove 4.500 ft consult your local gas supplier Maximum Inlet GAS Flow Pressure SettingGAS Line Sizing Water ConnectionsTo Turn OFF GAS to Appliance For Your Safety Read Before Lighting the PilotOperating Instructions What to do if YOU Smell GASPilot burner with air screen/ pilot orifice Maintenance and ServicePilot Light will not Light Pilot Lights but Flame Goes OUT When Button is ReleasedWater is not HOT Enough Burners do not Ignite When HOT Water is Turned onGas pressure too low Water is TOO HOTUnbalanced pressure in waterlines HOT Water Temperature Fluctuates / Unit DeactivatedDiagram of AquaStar 125 BS Interior Components Diagram and Parts List Interior Components Diagram Parts List 125BS Flow chart of Aquastar 125 BS General Limited WarrantyMaintenance Table see

125B NGS, 125B LPS specifications

Bosch Appliances has long been a revered name in the home appliance industry, recognized for its commitment to quality, innovation, and energy efficiency. Among its impressive lineup, the Bosch 125B NGS and the Bosch 125B LPS stand out for their advanced features and technologies that enhance the cooking experience in modern kitchens.

The Bosch 125B NGS is a gas cooktop designed for those who appreciate the precision of gas cooking. With its sleek stainless-steel design and intuitive controls, this appliance adds a touch of elegance to any kitchen. One of its main features is the rapid heating capability, thanks to the powerful burners that provide quick and even heat distribution. The cooktop includes multiple burner sizes, allowing users to choose the right heat level for various types of cooking, from simmering sauce to boiling pasta.

Additionally, the Bosch 125B NGS is equipped with an automatic re-ignition system, enhancing safety by ensuring that burners reignite if they go out. This feature is particularly beneficial in busy kitchen settings where distractions can occur. The continuous grate design allows for easy movement of pots and pans across the cooking surface, making multi-tasking a breeze.

On the other hand, the Bosch 125B LPS offers an electric alternative with a more modern flair. This built-in induction cooktop harnesses the power of induction technology, which uses magnetic fields to directly heat pots and pans. One of the key characteristics of this model is its exceptional energy efficiency, as it only heats the cookware, resulting in less wasted energy and cooler cooking surfaces. The Bosch 125B LPS features a touch control panel that allows for precise temperature adjustments at the touch of a finger.

Moreover, the model includes safety features such as a child lock and automatic shut-off, ensuring peace of mind for families. The sleek and minimalist design of the Bosch 125B LPS makes it a favorite among those who value aesthetics as much as functionality.

Both the Bosch 125B NGS and 125B LPS reflect the brand’s dedication to high-quality craftsmanship, innovative technology, and user-friendly operation, making them exemplary choices for anyone looking to elevate their culinary experience. Whether you prefer the hands-on approach of gas cooking or the quick precision of induction, Bosch offers reliable and versatile solutions to meet your kitchen needs.