Bosch Appliances 125B LPS, 125B NGS operating instructions Adaptor Used on High Altitude

Page 9

To check the draft:

Close all doors and windows to the outside.

Turn on all appliances that force air out of the building. These include all exhaust/ventilation fans, furnaces, clothes dryers, wood burning stoves, etc.

Open all doors between the AquaStar and these other appliances.

Run the unit for at least 10 minutes. Then hold an ordinary mirror at the side above the front shell. Any flue gases backdrafting will cause the mirror to fog. This is a serious health hazard and must be corrected. Poor venting can result in soot building up inside the heater, overheating of the heater and freezing of the heat exchanger in a freezing environment. The mirror will remain clear with a properly functioning draft.

WARNING

Note: The burners of an instantaneous “on demand” water heater such as the AquaStar are only on at the time that hot water is actually being used, the vent pipe is therefore cold except for the short durations when hot water is being used, it is therefore very important that the venting and air supply be adequate to provide a good positive draft as soon as the burners turn on. See venting guide on back page.

The AquaStar 125B”S” instantaneous water heaters have built-in draft diverters and are designed for indoor installation only. The draft diverter outlet must be connected to an unobstructed vent of the same size, or larger.

In Canada, CAN/CGA-B149 Installation Code for detailed requirements

In U.S.A., ANSI Z223.1 - NFPA 54, National Fuel Gas Code for detailed requirements.

The vent connection for the Aquastar 125BS is 5 inches. However, for installations at high altitude (over 2000 feet above sea level) a six inch vent is required. A 5” by 6” vent adaptor must be affixed to the flue collar of the Aquastar with at least two screws. See Fig. 3.

5” X 6” ADAPTOR

USED ON HIGH ALTITUDE

Fig. 3 – Vent Adaptor for High Altitude Installations

WARNING: Failure TO INCREASE THE VENT SIZE TO SIX INCHES AND/or assure that the manifold pressure is set to proper value listed for applications at high altitudes will cause unsafe venting, asphyxiation, and will void CSA Certification.

6 720 606 518

9

Image 9
Contents Table of Contents For Your SafetyFeatures Unpacking the Aquastar HeaterRequired Natural Gas Pressure at inlet tap Front View Side View Model 125BSTOP a Front B Back Sides Floor C Vent Diameter General Rules to Follow For Safe Operation Proper Location for Installing Your HeaterClearances Combustion AIR RequirementsAquastar 125 B S is design certified for mounting on a wall Mounting InstallationFigure a VentingFigure C 720 606 Masonry Chimneys6 Adaptor Used on High Altitude Vent Adaptor for High Altitude InstallationsFor LP GAS GAS Line Sizing For Natural GASGAS Line Sizing Maximum Inlet GAS Flow Pressure SettingWater Connections Above 4.500 ft consult your local gas supplierOperating Instructions For Your Safety Read Before Lighting the PilotWhat to do if YOU Smell GAS To Turn OFF GAS to AppliancePilot burner with air screen/ pilot orifice Maintenance and ServicePilot Light will not Light Pilot Lights but Flame Goes OUT When Button is ReleasedGas pressure too low Burners do not Ignite When HOT Water is Turned onWater is TOO HOT Water is not HOT EnoughUnbalanced pressure in waterlines HOT Water Temperature Fluctuates / Unit DeactivatedDiagram of AquaStar 125 BS Interior Components Diagram and Parts List Interior Components Diagram Parts List 125BS Flow chart of Aquastar 125 BS General Limited WarrantyMaintenance Table see

125B NGS, 125B LPS specifications

Bosch Appliances has long been a revered name in the home appliance industry, recognized for its commitment to quality, innovation, and energy efficiency. Among its impressive lineup, the Bosch 125B NGS and the Bosch 125B LPS stand out for their advanced features and technologies that enhance the cooking experience in modern kitchens.

The Bosch 125B NGS is a gas cooktop designed for those who appreciate the precision of gas cooking. With its sleek stainless-steel design and intuitive controls, this appliance adds a touch of elegance to any kitchen. One of its main features is the rapid heating capability, thanks to the powerful burners that provide quick and even heat distribution. The cooktop includes multiple burner sizes, allowing users to choose the right heat level for various types of cooking, from simmering sauce to boiling pasta.

Additionally, the Bosch 125B NGS is equipped with an automatic re-ignition system, enhancing safety by ensuring that burners reignite if they go out. This feature is particularly beneficial in busy kitchen settings where distractions can occur. The continuous grate design allows for easy movement of pots and pans across the cooking surface, making multi-tasking a breeze.

On the other hand, the Bosch 125B LPS offers an electric alternative with a more modern flair. This built-in induction cooktop harnesses the power of induction technology, which uses magnetic fields to directly heat pots and pans. One of the key characteristics of this model is its exceptional energy efficiency, as it only heats the cookware, resulting in less wasted energy and cooler cooking surfaces. The Bosch 125B LPS features a touch control panel that allows for precise temperature adjustments at the touch of a finger.

Moreover, the model includes safety features such as a child lock and automatic shut-off, ensuring peace of mind for families. The sleek and minimalist design of the Bosch 125B LPS makes it a favorite among those who value aesthetics as much as functionality.

Both the Bosch 125B NGS and 125B LPS reflect the brand’s dedication to high-quality craftsmanship, innovative technology, and user-friendly operation, making them exemplary choices for anyone looking to elevate their culinary experience. Whether you prefer the hands-on approach of gas cooking or the quick precision of induction, Bosch offers reliable and versatile solutions to meet your kitchen needs.