NO SPARK AT THE PILOT
1. On/Off switch is not ”On” (Position I).
The On/Off switch is located behind the flipdown cover plate on the front panel strip. See fig. 9.
2.Water flow is not sufficient to activate heater. Water flow rate at faucet is below minimum flow needed to activate heater. When temperature adjustment knob is turned all the way clockwise, the AquaStar model 125X requires 1/2 gallon per minute flow to activate the heater. As a reference, this is a flow which would fill a quart jar in
30seconds. If the temperature adjustment knob is turned fully counterclockwise, a flow rate of 1.1 gallons/minute is required to activate the heater.
3.Water inlet filter is clogged
Water flow is restricted, preventing needed flow to activate heater. Clean water inlet filter screen.
4. Cross over in water lines
To confirm there is no
5. Batteries are weak
The LED light (seen through the peephole in the coverplate on the front panel) flashes when the batteries are less than 1.2 volts. Replace batteries with D cell (1.5 volt) long life alkaline batteries as shown in fig. 9.
6. Microswitch needs to be adjusted or replaced.
If you do not hear a click when a tap is opened, the microswitch needs to be adjusted. See Fig. 12 for adjustment, or replace the microswitch if the heater has been in use for some time.
|
|
| Adjusting screw |
| G871 212 |
|
|
| Fig. 12 - microswitch adjustment | ||
|
|
|
|
| Pilot does not spark with |
| Pilot is always sparking |
| water flow |
| without water flow |
1 | Close water tap | 1 | Close water tap |
2 | Remove screw cap and | 2 | Screw in adjusting screw, |
| unscrew adjusting screw till |
| till it stops sparking |
| sparking starts |
|
|
3 | Screw in turning one and | 3 | Continue to screw in |
| half turns |
| turning one and half turns |
|
|
| more |
7.Cold incoming water connection made to wrong side of heater
Make sure cold water inlet connection is on the right side of heater when you are facing heater.
8.Water valve parts may be dirty or components damaged
First check that venturi is free of dirt particles. Water valve and component parts must be totally free of dirt. In hard water areas, mineral deposits can eventually
9.Loose connection at the ECO
Ignition sparker will not operate if the electrical circuit is interrupted. Check that the connections to the ECO are secure and tighten if necessary.
SPARKS APPEAR AT PILOT WHEN HOT WATER TAP TURNED ON, BUT PILOT AND BURNERS WILL NOT IGNITE
1. Air in the Gas Line
Normally this is a problem at time of initial installation, after the pipes have been worked on, or after a gas supply line has been allowed to empty. Bleed the air trapped in the gas line by turning the hot water faucet on and off until the air has been cleared from the line.
2. No gas to the AquaStar
A. Gas cock on gas line may not be open
B. Gas regulator may be shut or damaged. Replace or unjam the regulator. Note: The regulator furnished with the heater is exclusively designed for low gas pressure. Excessive pressure will lock it up. Jamming usually happens when using propane gas if f the gas pressure between the gas tank and the water heater’s gas regulator has not been reduced. See Page 2 for recommended correct gas pressure. To unjam a regulator, consult your gas supplier or call CEC.
3. Pilot orifice or gas valve is dirty
Clogging of the pilot burner can be caused by dust in the air or dirt in the gas. The pilot orifice or gas filter may need to be cleaned or replaced.
4. Water valve assembly needs to be checked
If the pilot orifice is clean, the water valve assembly should be checked. The adjustment screw on the water valve
5.Pilot electrovalve switch may need to be replaced (See Fig 13).
Call CEC.
6.Electronic Control Box may need to be replaced (See Fig 13).
Call CEC.
11