| INSTALLATION CHECKLIST |
| |||
|
|
|
| MODEL 125X |
| ||
|
| GAS LINE SIZE |
|
| |||
|
| Natural Gas |
|
| |||
Nominal Iron Pipe Size* |
| 1/2" |
| 3/4" | 1" |
| |
MAXIMUM LENGTH |
| 10' |
| 40' | 150' |
| |
|
| Liquid Propane |
|
| |||
| 1/2" |
| 5/8" | 3/4" | 7/8" | ||
MAXIMUM LENGTH |
| NOT |
| 20' | 60' | 150' | |
RECOM MENDED | |||||||
|
|
|
| ||||
* Flex tubing greatly reduces capacity and, therefore, is not recommended. | |||||||
Minim um Vent Size* and Height |
| ||||||
Minimum D iameter |
|
|
| Minimum Height** |
| ||
5 inches |
|
|
|
| 6 feet |
|
* NOTE: V ent size must not be restricted. Installation must com ply with national fuel gas code venting
requirem ents for a 117,000 B tu Category I appliance and any applicable local codes .
** NOTE: Minimum vent height m ust be 6 feet, provided there are no elbows . Termination of the vent must be 2 feet above any obstructionwithin a 10 foot radius of vent pipe. Consult your gas utility or National Gas Fuel Code if vent will have elbows or share venting with another appliance. The vent connector should have as m uch vertical rise as possible (minimum 12") before any horizontal run.
Water Pressure
For installation on well system s, insure that your water pressure is between 30 - 50 psi.
MAINTENANCE TABLE see page10
|
| EVERY YEAR | EVERY 2 YEARS | EVERY |
|
|
|
|
|
| LUBRICATE WATER VALVE |
| † |
|
|
|
|
|
|
| REBUILD WATER VALVE |
|
| † |
|
|
|
|
|
| INSPECT WATER FILTER SCREEN | † |
|
|
|
|
|
|
|
| INSPECT PILOT ASSEMBLY | † |
|
|
|
|
|
|
|
| INSPECT VENT ASSEMBLY | † |
|
|
|
|
|
|
|
| INSPECT MAIN BURNER | † |
|
|
|
|
|
|
|
Replacement Parts available from North American
Distributor
CONTROLLED ENERGY CORP.
340 Mad River Park
Waitsfield, Vermont 05673
Phone
Fax (802)
www.controlledenergy.com
techsupport@controlledenergy.com
Recycled paper
VULCANO Termodomésticos S.A.
Estrada de Cacia
3801 - 856 Aveiro - PORTUGAL
©2001ControlledEnergyCorporation,Waitsfield,VT allrightsreserved