Bosch Appliances 125B LP, 125B NG specifications Interior Components Diagram Parts List 125B

Page 21

Fig. 13

INTERIOR COMPONENTS DIAGRAM

AND PARTS LIST 125B

1

Cover

8 705 421 025

 

2

Temperature adjustment knob

8 702 000 111

 

3

Temperature adjustment collar

8 700 403 008

 

4

Draft diverter

8 705 505 354

 

5

Heat exchanger

8 705 406 235

 

6

Outlet flex hose

8 700 703 130

 

7

Washer

8 700 103 658

 

8

Cold water pipe

8 700 705 627

 

9

Main burner

8 708 120 298 NG

9

Main burner

8 708 120 296 LP

10

Pilot burner

8 718 105 051

 

11

Pilot air screen

8 700 507 055

 

12

Piezo electrode

8 708 107 002

 

13

Pilot injector

8 708 200 005

NG

13

Pilot injector

8 748 200 173

LP

14

Pilot tube

8 700 707 320

 

15

Burner assembly washer

8 710 103 060

 

16

Throttle disc

8 700 100 174

LP

17

Gas valve

8 707 021 090 NG

17

Gas valve

8 707 021 091 LP

18

Gas supply pipe

8 700 705 552

 

19

Electromagnet

8 707 201 012

 

20

Thermocouple / Flue Gas Sensor

8 707 206 074

 

21

Water valve

8 707 002 649

 

22

Water valve cover

8 705 500 101

 

23

Pushrod

8 700 306 114

 

24

Diaphragm

8 700 503 053

 

25

Water inlet filter

8 700 507 001

 

26

Water connection gasket

8 710 103 043

 

27

Water valve selector screw

8 708 500 289

 

28

Volumetric water governor

8 705 705 009

 

29

Venturi

8 708 205 279

 

30

Water elbow fitting

8 700 703 114

 

31

Overheat sensor (ECO)

8 707 206 040

 

32

Connecting pipe hot

8 700 715 178

 

34

Washer

8 710 103 045

 

35

Water valve set screw

8 703 401 051

 

6 720 607 030

21

Image 21
Contents For Your Safety Table of ContentsWhat to do if YOU Smell GAS Unpacking the Aquastar Heater FeaturesFront View Side View Aquastar Model 125BGeneral Rules to Follow For Safe Operation Proper Location for Installing Your HeaterClearances Combustion AIR RequirementsMounting the Heater Mounting InstallationEstablish a ONE Foot Rise Before ANY Elbows VentingFigure C Masonry Chimneys6 Adaptor Used on High Altitude Vent Adaptor for High Altitude InstallationsMaximum Inlet GAS Flow Pressure Setting GAS ConnectionsGAS Line Sizing For LP GAS GAS Line Sizing For Natural GASFor Your Safety Read Before Lighting the Pilot Water ConnectionsOperating Instructions To Turn OFF GAS to Appliance Setting the Water TemperatureAIR Screen Pilot Orifice Pilot Lights but Flame Goes OUT When Button is Released Burners do Notignite When HOT Water is Turned onPilot Light will not Light Water is not HOT Enough Water is TOO HOTUnbalanced pressure in waterlines HOT Water Temperature Fluctuates / Unit Deactivated720 607 Diagram of AquaStar 125 B Interior Components Diagram and Parts List Interior Components Diagram Parts List 125B Limited Warranty Flow chart of Aquastar 125 B Maintenance Table see pages 13

125B NG, 125B LP specifications

Bosch Appliances has long been a trusted name in kitchen technology, and their 125B LP and 125B NG models are no exception. These gas appliances combine advanced features with top-notch engineering, ensuring excellent performance and reliability in the kitchen. Designed for both professionals and home cooks, the 125B series caters to diverse culinary needs.

One of the main features of the Bosch 125B model is its dual fuel capability. The LP (liquefied petroleum) and NG (natural gas) options make it flexible for various installations and preferences. This versatility ensures that users can easily find the right setup for their kitchens, whether they're using propane or natural gas.

The burners in the 125B series are designed with precision in mind. Each model features high-efficiency burners that deliver a maximum output of 15,000 BTUs. This level of power enables rapid heating for boiling, frying, or searing, while the low-simmer setting allows for gentle cooking tasks such as sauces and delicate soups. The continuous cast iron grates offer both durability and stability, allowing for easy movement of pots and pans across the cooking surface.

An additional technological highlight of the Bosch 125B series is the flame failure safety device. This essential safety feature automatically cuts off the gas supply if the flame goes out, providing peace of mind for users. The inclusion of electronic ignition also enhances convenience, making it easy to start the burners with just a turn of the knob.

The sleek design of the Bosch 125B appliances blends seamlessly into any kitchen decor. With a professional stainless steel finish, they add an element of sophistication while being easy to clean and maintain. The intuitive control knobs are ergonomically designed, ensuring smooth and precise adjustments to the flame.

In terms of installation, both the 125B LP and NG models are designed for straightforward setup, making them suitable for renovation projects or new builds. Bosch Appliances also offers a range of accessories to further enhance the functionality and aesthetic of the kitchen setup.

Overall, the Bosch 125B LP and 125B NG appliances represent a perfect combination of efficiency, safety, and style. With their robust features and advanced technology, they promise to elevate the cooking experience for anyone who values quality and performance in the kitchen. Whether you're a novice home cook or a seasoned chef, these models are sure to meet and exceed your culinary expectations.