Electrical Connections

Before any electrical connections are made, be sure that the water heater is full of water and that the manual shut-off valve in the cold water supply line is open. If the heating elements are not completely immersed in water at all times, they will be damaged (burned-out) if energized for even a short period of time. The warranty does not cover burned-out heating elements. Check the rating plate and wiring diagram before proceeding. This electric water heater was built and wired in accordance with the Underwriters Laboratories testing approvals requirements. The temperature-limiting device is of the manual reset, trip-free type and has been factory installed to interrupt all ungrounded power supply conductors in the event of thermostat failure. The plumbing supplier in your area ordered this water heater wired at the factory to comply with existing area codes, but local utility codes may require or allow other circuitry. Consult your local power company to determine the correct electrical hook-up in order to meet local utility and building codes and in order to obtain the most economical rates. All electrical connections to elements, thermostats, and contactors (certain models) have been made at the factory. DO NOT alter any of the internal wiring. Wiring connections may loosen during shipment. Check all connections for tightness.

To make the wiring connections to a power supply, follow the steps below.

 

A) Open cover door of the control box.

 

 

 

B) Bring the power leads from an adequately fused disconnect switch

(not

furnished with the water heater due to varying state and local

codes) and

connect to the terminal block. Where long runs, local

ordinances or utility

company necessitates, an increase in size may be

required.

 

C) This water heater must be properly grounded. A ground lug is

provided

 

within the electrical control box for connection to a properly

sized

 

ground. (See wiring diagram for minimum required ground size.

Wiring

 

diagram is located on the inside door of the control box)

 

 

 

D) Close cover door of the control box.

 

 

 

Heating Elements

To replace heating elements, disconnect power to the water heater, drain tank and replace element. To remove a heating element, use a 1 1/2” screw type element wrench available from most supply houses. Do not over-tighten the new element, as this will cause distortion in the new element gasket. Once the element has been replaced, follow the instructions “To Fill The Water Heater”. It is imperative that the water heater is full before power is restored to the heating elements.

Electrical Connections continued-

Amperage Chart

14

Image 14
Contents Installation & Operating Congratulations Table of Contents General Information General Information Installation Locating The Water HeaterWater Connections Being Certain IT is Filled with Water Water Connections Water Connections Water Connections Page Dual Water Heater Installation Heating Elements General Operation 208V 240V 277V 380V 415V 480V InputThermostat Adjustment Thermostat Adjustment Maintenance Maintenance Maintenance Page

238-16152-00F specifications

Bradford-White Corporation is a well-known name in the water heating industry, offering innovative products designed for both residential and commercial applications. Among its extensive lineup, the Bradford-White Corp 238-16152-00F is a standout model that showcases the company's commitment to quality, efficiency, and advanced technology.

The 238-16152-00F is primarily recognized as a gas water heater, built to provide reliable hot water for various needs, from domestic use to larger applications. One of the main features of this model is its high energy efficiency, which contributes to lower utility bills and reduced environmental impact. The unit is designed with advanced insulation technologies and a robust heat exchanger that ensures optimal heat retention and transfer.

Safety is a top priority in the design of the 238-16152-00F. It includes multiple safety features such as a temperature and pressure relief valve, which prevents potential hazards associated with thermal expansion and pressurization. The model is also equipped with an electronic ignition system that enhances reliability while minimizing the risk of pilot light outages. This technology ensures that the heater ignites only when there is a demand for hot water, leading to increased energy efficiency.

Another significant characteristic of the 238-16152-00F is its user-friendly interface, which allows for easy adjustments and monitoring of water temperature settings. This feature is especially beneficial for homeowners who want to customize their hot water experience according to their specific needs.

The build quality of Bradford-White products, including the 238-16152-00F, is exceptional. Constructed with durable materials, the tank is designed to resist corrosion, ensuring longevity and reliability. Additionally, the unit often incorporates features such as a self-cleaning mechanism, which helps to reduce sediment buildup and maintain efficiency over time.

With its combination of efficiency, safety features, and robust construction, the Bradford-White Corp 238-16152-00F is an excellent choice for anyone in need of a dependable water heating solution. Whether for residential spaces or commercial facilities, this model exemplifies the innovation and quality associated with Bradford-White, making it a preferred option in the market.