Bradford-White Corp M1XR65T*(BN, MI75S*(BN, GX155S*BN, GX225S*BN, MI100T*(BN Troubleshooting Chart

Page 3

Troubleshooting Chart

SYMPTOM

PROBABLE CAUSE CORRECTIVE ACTION

SERVICE

PROCEDURE

Pilot will not light

Pilot will not

stay lit

when button is

released

1.No incoming gas or too low gas pressure.

2.Gas control knob set to wrong position.

3.Pilot light button not being fully depressed when attempting to light pilot.

4.Pilot orifice or pilot tube is obstructed or kinked.

1.Poor thermocouple connection at combination thermostat/gas valve.

2.Thermocouple not fully engaged in pilot assembly bracket.

3.Pilot flame is not fully enveloping the thermocouple “hot” junction.

4.Weak or defective thermocouple.

5.Open ECO on combination thermostat/ gas valve.

6.Defective magnet in combination thermostat/gas valve.

1.Turn on gas supply and/or check line pressure.

2.Review lighting instruction. Set combination/thermostat

gas valve to correct position.

3.Review lighting instruction. Fully depress pilot lighting button.

4.Clean, repair or replace.

1.Check connection at combination thermostat/gas valve. Proper tightness should be finger tight plus ¼ turn.

2.Inspect thermocouple to ensure that it is fully engaged into pilot bracket.

3.Adjust tip of thermocouple to be fully engulfed by pilot flame.

4.Check thermocouple and replace if necessary.

5.Check ECO continuity and replace combination thermostat/gas valve if necessary.

6.Check magnet operation and replace combination thermostat/gas valve if necessary.

1.See Service Procedure AG-III, Page 6.

4.See Service Procedure AG-II, Page 5.

4.See Service Procedure AG-I, Page 4

5.See Service Procedure AG-III, Page 6

6.See Service Procedure AG-III, Page 6

Pilot will light, but the main burner will not come on

Pilot goes out

periodically (after

heating cycles,

once a day, once

a week etc.)

Not enough hot

water

1.Combination thermostat/gas valve set too low for desired water temperature.

2.Combination thermostat/gas valve temperature is satisfied.

3.Insufficient gas supply or low gas pressure.

4.Combination thermostat/gas valve has wide differential or is out of calibration.

1.Insufficient combustion air supply.

2.Incorrect, clogged vent system/ vent terminal or location.

3.Inconsistent gas supply or gas pressure.

1.Combination thermostat/gas valve set too low for desired water temperature.

2.Cold inlet water temperature is very cold.

3.High demand periods.

4.Incorrectly sized water heater for application.

5.Combination thermostat/gas valve is out of calibration/not functioning.

6.Out of spec dip tube is diluting hot water with cold water.

7.Integrated mixing device is set too low for desired water temperature.

1.Adjust temperature dial on combination thermostat/gas valve.

2.Check temperature dial setting on combination thermostat/gas valve.

3.Check gas supply and line pressure.

4.Check combination thermostat/gas valve for proper operation, replace if necessary.

1.Verify adequate combustion air is available to the unit. Check and clear Jacket slot openings of any dirt, dust, restrictions or other obstructions.

2.Check venting for proper sizing and proper operation

3.Check gas supply and line pressure.

1.Check dial on combination thermostat/gas valve.

2.Extremely cold water going into the heater will decrease the amount of hot water produced. It may be necessary to temper incoming water supply.

3.Adjust high demand usage.

4.Contact Plumbing professional.

5.Check combination thermostat/gas valve for proper operation, replace if necessary.

6.Inspect dip tube and replace if necessary.

7.Reset device using the procedure

in the instructions included with the device.

2.See Installation & operation manual.

3.See Service Procedure AG-III, Page 6

4.See Service Procedure AG-III, Page 6

3.See Service Procedure AG-III, Page 6

5.See Service Procedure AG-III, Page 6

6.See Service Procedure AG-V, Page 13

Page 3

3

Image 3
Contents Service Manual Table of Contents Troubleshooting Chart Thermocouple Replacement Open Circuit Thermocouple TestingFeedline Nut Pilot Orifice Pilot Assembly INSPECTION, Cleaning and ReplacementLine Pressure Combination Thermostat/Gas Valve Testing and ReplacementThermocouple Testing Magnet Assembly Testing White Rodgers ControlMagnet Assembly Testing Robertshaw Control Combination THERMOSTAT/GAS Valve Replacement ECO Energy Cut Off TestingService Procedure AG-III Cast Iron Burner Adjustment Main Burner Inspection, Adjustment Cleaning and ReplacementBurner Venturi Opening Feedline Burner Cleaning DIP Tube Inspection and Replacement Anode Inspection and Replacement Page Fax/215-641-1612

M1XR65T*(BN, MI75S*(BN, M2XR75S*(BN, GX155S*BN, 65T65*(BN specifications

Bradford-White Corp has long been recognized for its expertise in manufacturing water heating solutions that are durable, efficient, and built to last. Among their diverse range of products, the Bradford-White GX225S*BN, 75T80*(BN, MI100T*(BN, 55X80B*N, 25X78B*N stands out as an advanced and high-performing water heater that meets modern residential and commercial needs.

The GX225S*BN demonstrates exceptional functionality and reliability. This model offers a substantial capacity of 75 gallons, making it suitable for larger households or establishments that require a steady supply of hot water for multiple fixtures and appliances simultaneously. Equipped with advanced insulation technology, it efficiently retains heat, leading to lower energy consumption and reduced utility costs.

One notable feature of the GX225S*BN is its intuitive user interface, which simplifies temperature control and monitoring. Users can easily adjust the temperature settings to meet their comfort levels while ensuring safe operation. Safety is a top priority; thus, the water heater includes a comprehensive safety system that prevents overheating and includes a temperature and pressure relief valve, ensuring peace of mind for users.

The innovative design of the water heater utilizes high-quality, durable materials resistant to corrosion, which enhances its lifecycle and reduces maintenance requirements. The heater also integrates advanced venting technologies to optimize performance and facilitate installation, allowing flexibility in positioning.

Bradford-White’s commitment to craftsmanship is evident in the GX225S*BN’s construction and performance. This model features an efficient burner system that maximizes energy output while minimizing emissions, contributing positively to environmental efforts. Additionally, the unit operates quietly, ensuring that it does not disrupt the household or business environment.

The GX225S*BN also meets compliance with energy efficiency regulations, which is crucial both for environmentally conscious consumers and for those looking to save on energy bills. With industry-leading warranties and support from Bradford-White Corp, users can rest assured that they are investing in a reliable product that stands the test of time.

In conclusion, the Bradford-White GX225S*BN, 75T80*(BN, MI100T*(BN, 55X80B*N, 25X78B*N is designed to meet the demands of modern hot water needs while providing exceptional efficiency, safety, and durability. It represents a significant investment for those seeking a robust water heating solution that prioritizes user satisfaction and energy conservation.