American Water Heater 318935-003 installation instructions For Your Safety Read Before Lighting

Page 18

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which is lighted by a piezoelectric igniter. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

‡Do not try to light any appliance.

‡Do not touch any electrical switch; do not use any phone in your building.

‡Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

‡If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control temperature knob. Never use tools. If the knob will not push in or move by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance. Water heaters subjected to flood conditions or anytime the gas controls, main burner or pilot have been submerged in water require replacement of the entire water heater.

E.DO NOT USE THIS APPLIANCE IF THERE HAS BEEN AN IGNITION OF VAPORS. Immediately call a qualified service technician to inspect the appliance. Water heaters subjected to a flammable vapors ignition will show a discoloration on the air intake grid (bottom of combustion chamber) and require replacement of the entire water heater.

LIGHTING INSTRUCTIONS

1.STOP! It is imperative that you read all safety warnings before lighting the pilot.

2.Turn the gas control/temperature knob counterclockwise to the "OFF" setting.

Gas control/

120° F (48.9° C)

temperature knob

Mark

Igniter

Button

Status light

Index mark

 

3.Wait ten (10) minutes to clear out any gas.

If you then smell gas, STOP! Follow “ B” in the safety information above on this label. If you do not smell gas, go to the next step.

4.Turn the gas control/temperature knob clockwise

to “ PILOT” .

5.Press the gas control/temperature knob all the way in and hold it in. The knob should travel in about 1/4 inch (6.35 mm) if it is set to "PILOT" correctly.

While holding the gas control/temperature knob in, click the igniter button continuously (about once a second) for up to 90 seconds or until Status Light begins to blink.

6.When the status light starts blinking, release the gas control/temperature knob. Set the gas control/ tempera- ture knob to the desired setting.

If the status light does not start blinking within 90 seconds, repeat steps 2 through 5 up to THREE (3) times, waiting 10 minutes between lighting attempts.

The circuitry in this advanced gas valve requires that you wait 10 minutes between lighting attempts.

If the status light turns solid red, release the gas control/temperature knob and repeat steps 2 through 5 (waiting 10 minutes before attempting to relight the pilot).

If the status light does not start blinking after three lighting attempts, turn the gas control/temperature knob to "OFF" and call a qualified service technician or your gas supplier.

Thermopile

Pilot

TO TURN OFF GAS TO APPLIANCE

1.Turn the gas control/temperature knob counterclockwise to the "OFF" setting. The status light will stop blinking and stay on for a short time after the water heater is turned off.

18

Image 18
Contents What to do if YOU Smell GAS JuneWater Heater Safety Consumer Responsibilities Important Information About This Water HeaterConsumer Information Unpacking the Water HeaterLocation Requirements Site LocationClearances and Accessibility State of CaliforniaGas Requirements Gas Pressure TestingGas Supply Gas PressureCombustion Air Supply and Ventilation Unconfined Space Confined SpaceAll Air from Inside the Building All Air from Outdoors Louvers and GrillesVent Pipe System Draft Hood InstallationVent Connectors Vent Pipe SizeChimney Connection Vertical Exhaust Gas VentPiping Installation Water System PipingClosed System/Thermal Expansion Relief Valve and Pipe Insulation Some Models Temperature and Pressure Relief ValveTemperature & Pressure Relief Valve Discharge LineSolar Installation Special ApplicationsCombination Space Heating/Potable Water System Installation Checklist Lighting Instructions Explosion HazardFor Your Safety Read Before Lighting Burner Flames Water Temperature StackingChecking the Draft Emergency Shut DownWater Temperature Regulation 154 Instantaneous SecondsOperating Modes and Settings Operating the Temperature Control SystemWater Temperature Adjustment Operational ConditionsAnode Rod/Water Odor Routine Preventative Maintenance Draining and FlushingReplacement Parts Removing the Burner Door AssemblyNatural Gas Burner Ultra Low Nox Replacing the Pilot/Thermopile Assembly External Inspection & Cleaning of the Flame-trap Cleaning the Combustion Chamber and Flame-trapReplacing the Burner Door Assembly Testing the Igniter System Piezoelectric Igniter SystemFlame Guard Safety System Operational Checklist Removing and Replacing the Gas Control Valve/ThermostatSlow HOT Water Status Light Code Troubleshooting Chart Pilot Light Troubleshooting Chart Repair Parts List Parts DescriptionListed Parts Kits and Illustrations Page

318935-003 specifications

The American Water Heater 318935-003 stands out as a reliable option for residential and commercial hot water needs. Manufactured by American Water Heater Company, a brand known for its commitment to quality and innovation, this model integrates several advanced features and technologies to enhance efficiency, durability, and user experience.

One of the defining characteristics of the 318935-003 is its impressive efficiency rating. Designed with energy conservation in mind, it employs a highly efficient heating process that significantly reduces energy consumption. This not only helps in lowering utility bills for homeowners and businesses but also contributes to a more sustainable environment. The water heater meets or exceeds Energy Star guidelines, making it an eco-friendly choice.

The technology used in this model includes a state-of-the-art thermostat and advanced insulation material that ensures optimal heat retention. This dual approach minimizes heat loss, ensuring that hot water is readily available when needed while maintaining consistent temperatures. The adjustable thermostat allows users to customize settings to their preferences, thus improving comfort and efficiency.

Additionally, the 318935-003 features a robust design with high-quality materials that enhance its longevity. Its tank is constructed from durable steel, coated with a corrosion-resistant finish, which ensures that it withstands the test of time and minimizes maintenance needs. The unit is also equipped with a comprehensive safety system that includes a temperature and pressure relief valve, safeguarding against potential malfunctions.

The installation process of the American Water Heater 318935-003 is straightforward, making it accessible for both professionals and DIY enthusiasts. It is compatible with various plumbing systems and configurations, offering flexibility in installation locations. Maintenance is also user-friendly, with accessible components that allow for easy upkeep.

In summary, the American Water Heater 318935-003 embodies the ideal blend of efficiency, durability, and advanced technology. Its energy-efficient design, robust construction, and user-friendly features make it a top choice for anyone looking to fulfill their hot water requirements. Whether for a busy household or a commercial establishment, this water heater delivers consistent performance, ensuring a reliable supply of hot water year-round. Investing in the 318935-003 means investing in long-term satisfaction and efficiency, making it a wise addition to any space.