A.O. Smith BT- 80 warranty Dimensions, Recovery Ratings

Page 2

ROUGH-IN DIMENSIONS

FIGURE 1.

DIMENSIONS

Model

Units

A

B

C

D

E

F

G

H

J

K

L

M

BT-80

Inches

61 1/8

58 1/2

29 11/16

26 1/2

15 3/16

4

14 1/2

16

1 1/4

1

1/2

11 15/16

Natural & LP

C M

155.25

148.6

75.4

67.3

38.6

10.2

39.4

40.6

3.2

NPT

NPT

30.3

BT-100

Inches

68 5/8

66 1/2

30 15/16

27 3/4

15 3/16

4

15 3/4

16

1 1/4

1 1/4

1/2

11 15/16

Natural & LP

CM

174.3

168.9

78.59

70.5

38.6

10.2

40.0

40.6

3.2

NPT

NPT

30.3

RECOVERY RATINGS

 

Input

Approx.

Approx.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Rating

Rating

Gal.

Liter

Temp.

17

22

28

33

39

44

50

56

61

67

72

78

 

Btu/Hr

kW

Cap.

Cap.

Rise

30

40

50

60

70

80

90

100

110

120

130

140

BT- 80

75,100

22.0

74

280

GPH

243

182

146

121

104

91

81

73

66

61

56

52

 

 

 

 

 

LPH

916

686

550

456

392

343

305

275

249

230

211

196

BT -100

75,100

22.0

98

371

GPH

243

182

146

121

104

91

81

73

66

61

56

52

 

 

 

 

 

LPH

916

686

550

456

392

343

305

275

249

230

211

196

Recovery ratings based on 80% thermal efficiency.

FOREWORD

The design of models BT-80 and 100 comply with the current edition of ANSI Z21.10.3-CSA 4.3 as automatic storage or automatic circulating tank type water heaters.

Installation diagrams are found in this manual. These diagrams will serve to provide the installer with a reference for the materials and method of piping necessary. It is highly essential that all water and gas piping be installed as shown on the diagrams.

In addition to these instructions, the equipment shall be installed in

accordance with those installation regulations in force in the local area where the installation is to be made. These shall be carefully followed in all cases. Authorities having jurisdiction should be consulted before installations are made.

In the absence of local codes, the installation must comply with the current edition of the National Fuel Gas Code, ANSI Z223.1/NFPA 54 or the Natural Gas and Propane Installation Code CAN/CSA-B149.1. These documents are available from the Canadian Standards Association, 8501 East Pleasant Valley Road, Cleveland, OH 44131.

2

Image 2 Contents
Installation Operation Service Maintenance Limited Warranty Commercial GAS Water HeaterDimensions Recovery RatingsTable of Contents Installation Instructions Hard Water High Altitude InstallationsClearances AIR RequirementsConfined Space Water Potable Heating and SpaceVenting System ConnectionsRelief Valve Vent ConnectionGAS Piping and Dirt LEG Installation GAS Meter Size GAS PipingPurging GAS Pressure RegulatorTo Operate the Water Heater Page For Your Safety Read Before Lighting What to do if YOU Smell GASTemperature Regulation Check VentingPilot and Main Burner Service InformationHigh Temperature Limit Switch Checking GAS InputHOT Water Odor Replacement PartsVent System Anode ROD InspectionDeliming Solvents Preventive MaintenanceTank Cleanout Procedure Checklist Water Heater Makes Sounds Model BT Limited Warranty Page Smith Water Products Company