of the building. Turn on all appliances not connected to the venting system. Turn on all exhaust fans, such as range hoods and bathroom exhausts, so they shall operate at maximum speed. Close fireplace dampers.

4.Follow the lighting instruction. Place the water heater being inspected in operation. Adjust thermostat so appliance shall operate continuously.

5.Test for draft hood spillage at the relief opening after 5 minutes of main burner operation.

6.After it has been determined that each appliance connected to the venting system properly vents when tested as outlined above, return doors, windows, exhaust fans, fireplace dampers and any other gas burning appliance to their previous conditions of use.

7.If improper venting is observed during any of the above tests, the venting system must be corrected.

WARNING

FAILURE TO CORRECT BACK DRAFTS MAY CAUSE AIR CONTAMINATION AND UNSAFE CONDITIONS.

If the back draft cannot be corrected by the normal method or if a suitable draft cannot be obtained, a blower type flue gas exhauster must be employed to assure proper venting and correct combustion.

SERVICE INFORMATION

The installer may be able to observe and correct certain problems which may arise when the unit is put into operation. HOWEVER, it is recommended that only qualified servicemen, using appropriate test equipment, be allowed to service the heater.

FOR YOUR SAFETY AND SATISFACTORY OPERATION, IT IS RECOMMENDED THAT THIS HEATER BE CHECKED ONCE A YEAR BY A COMPETENT SERVICE PERSON.

USERS OF THIS APPLIANCE SHOULD BE AWARE THAT GAS COMPONENTS WEAR OUT OVER A PERIOD OF TIME. THE GAS CARRYING COMPONENTS OF THIS APPLIANCE SHOULD BE INSPECTED FOR PROPER OPERATION PERIODICALLY BY A QUALIFIED SERVICE TECHNICIAN.

PILOT AND MAIN BURNER

Check pilot, figure 7, and main burner at least every 6 months for proper flame characteristics. The main burner should display the following characteristics:

1.Provide complete combustion of gas.

2.Cause rapid ignition and carryover of flame across entire burner.

3.Give reasonably quiet operation during ignition, burning and extinction.

4.Cause no excessive lifting of flames from burner ports.

If preceding burner characteristics are not evident, check for accumulation of lint or other foreign material that restricts or blocks the air openings to the heater or burner.

WARNING

SOOT BUILD-UP INDICATES A PROBLEM THAT REQUIRES CORRECTION BEFORE FURTHER USE. CONSULT WITH A QUALIFIED SERVICE TECHNICIAN.

Should the main burner or burner air openings require cleaning, remove the burner and clean with a soft brush. Clean main burner orifice with a suitable soft material. Do not disassemble burner head unless necessary.

CHECK FOR GOOD FLOW OF COMBUSTION AND VENTILATING AIR TO THE UNIT. MAINTAIN A CLEAR OPEN AREAAROUND THE HEATER AT ALL TIMES. DO NOT STORE COMBUSTIBLES OR FLAMMABLE LIQUIDS NEAR OR AROUND AN APPLIANCE.

PILOT AND MAIN BURNER

FIGURE7

CHECKING GAS INPUT

For appliance installation locations with elevation above 2000 ft.(610m) refer to HIGH ALTITUDE INSTALLATIONS section of this manual for input reduction procedure.

With this heater in operation, determine whether it is receiving the full rated input of gas. This may be done by timing the gas meter and measuring gas pressure with a gauge or manometer. When the heater is operating at full capacity (full gas input) it should consume approximately 1 cubic foot of gas in the time shown in table 3.

TABLE 3

INPUT CHECK TIME REQUIRED TO

CONSUME 1 CU. FT. OF GAS

 

 

 

Time Required To

 

Type of

BTU Per

Consume 1 Cu. Ft.

Model

Gas

Cu. Ft.

of Gas

BT-65

Natural

1050

58.2 sec.

BT-65

Propane

2500

163.7 sec.

Use this formula to “clock” the meter. Be sure that other gas consuming appliances are not operating during this interval.

3,600 X H = Btuh

T

T = Time in seconds needed to burn one cubic foot of gas.

H = Heating value of gas in Btu’s per cubic foot of gas.

Btuh = Actual heater input rate. Example: (Using BT-65 heater)

T = 58.2 seconds/ft3

H= 1,050 Btu/ft3 (natural gas) Btuh = ?

3,600 X 1,050 = 64.948 Btu/hr (19.0 KW)

58.2

12

Image 12
Contents Installation Operation Service Maintenance Limited Warranty Division of A.O. Smith CorporationSTRATFORD, ONTARIO, Canada Dimensions Recovery CapacitiesTable of Contents General Safety InformationInstallation Instructions High Altitude InstallationsInsulation Blankets Required AbilityClearances Hard WaterAIR Requirements Combination Water Potable Heating and Space HeatingVenting Relief ValveSystem Connections Draft HoodSingle Temperature GAS PipingPurging GAS Pressure RegulatorGAS Meter Size Natural GAS only Manifold Pressure Setting GasFor Your Safety Read Before Lighting Temperature Regulation High Temperature Limit SwitchChecking Venting Service Information Pilot and Main BurnerChecking GAS Input Pilot and Main BurnerChecklist Water Temperature is TOO HOT GAS Smellat the HeaterWater Leakage is Suspected Water Heater Makes SoundsModel BT Limited Warranty Replacement Parts

BT- 65 specifications

A.O. Smith BT-65 is a high-performance water heater designed to meet the diverse needs of residential and commercial users. Known for its energy efficiency and innovative features, the BT-65 is an excellent choice for those seeking reliable hot water solutions.

One of the standout features of the A.O. Smith BT-65 is its impressive capacity. With a storage capacity of up to 65 gallons, this water heater is ideal for large families or businesses that require a consistent supply of hot water. This large capacity ensures that no one has to wait for hot water, even during peak usage times.

In terms of technology, the BT-65 employs advanced insulation materials that significantly reduce heat loss, making it one of the most energy-efficient models available. This contributes to lower energy bills and a smaller carbon footprint. The unit is also equipped with a high-efficiency burner, which ensures quick heating of water while consuming less fuel. The savings in energy consumption makes the BT-65 an economically wise long-term investment.

Safety is another crucial aspect of the A.O. Smith BT-65. The model includes several safety features, such as a temperature and pressure relief valve that prevents excessive pressure buildup. Additionally, it is designed with a flame arrestor which enhances combustion safety, making it suitable for various installations.

The A.O. Smith BT-65 is also user-friendly, featuring an easy-to-read digital thermostat that allows users to set their desired water temperature with precision. This technology promotes convenience and comfort, allowing homeowners to enjoy their hot water experience without any hassle.

Furthermore, the BT-65 is built with durability in mind. It features a robust tank constructed from high-quality materials that resist corrosion and extend the lifespan of the unit. A.O. Smith backs this model with a solid warranty, providing peace of mind regarding its long-term performance.

In conclusion, the A.O. Smith BT-65 is a blend of capacity, efficiency, safety, and durability. With notable features like its large storage capacity, advanced insulation technology, and user-friendly design, it stands out as a reliable choice for anyone in search of an effective water heating solution. Whether for residential or commercial use, the BT-65 is crafted to deliver consistent and efficient hot water when you need it most.