A.O. Smith ECS-30, EJC-30 Installing the NEW Water Heater, Insulation Blankets, Water Piping

Page 7

3.The water heater should be located so it is not subject to physical damage by moving vehicles or area flooding.

Installation of the water heater must be accomplished in such a manner that if the tank or any connections should leak, the flow will not cause damage to the structure. For this reason, it is not advisable to install the water heater in an attic or upper floor. When such locations cannot be avoided, a suitable drain pan should be installed under the water heater. Drain pans are available from your local plumbing contractor. Such a drain pan must have a minimum length and width of at least 2 inches (51

mm)greater that the water heater dimensions and must be piped to an adequate drain.

Water heater life depends upon water quality, water pressure and the environment in which the water heater is installed. Water heaters are sometimes installed in locations where leakage may result in property damage, even with the use of a drain pan piped to a drain. However, unanticipated damage can be reduced or prevented by a leak detector or water shut-off device used in conjunction with a piped drain pan. These devices are available from some plumbing supply wholesalers and retailers, and detect and react to leakage in various ways:

Sensors mounted in the drain pan that trigger an alarm or turn off the incoming water to the water heater when leakage is detected.

Sensors mounted in the drain pan that turn off the water supply to the entire home when water is detected in the drain pan.

Water supply shut-off devices that activate based on the water pressure differential between the cold water and hot water pipes connected to the water heater.

INSULATION BLANKETS

Insulation blankets are available to the general public for external use on electric water heaters but are not necessary with this product. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters. Your water heater meets or exceeds the National Appliance Energy Conservation Act standards with respect to insulation and standby loss requirements, making an insulation blanket unnecessary.

Should you choose to apply an insulation blanket to this heater, you should follow these instructions below. Failure to follow these instructions can result in fire, serious personal injury, or death.

Do not cover the temperature and pressure relief (T & P) valve with an insulation blanket.

Do not cover the instruction manual. Keep it on the side of the water heater or nearby for future reference.

Do obtain new warning and instruction labels for placement on the blanket directly over the existing labels.

INSTALLING THE NEW WATER HEATER

WATER PIPING

HOTTER WATER CAN SCALD:

Water heaters are intended to produce hot water. Water heated to a temperature which will satisfy space heating, clothes washing, dish washing, cleaning and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physically/mentally disabled. If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap, then you must take special precautions. In addition to using the lowest possible temperature setting that satisfies your hot water needs, a means such as a mixing valve should be used at the hot water taps used by these people or at the water heater. Valves for reducing point of use temperature by mixing cold and hot water are also available.

Consult a Qualified Installer or Service Agency. Follow manufacturer’s instructions for installation of the valves. Before changing the factory setting on the thermostat, read the “Temperature Regulation” section in this manual.

This water heater shall not be connected to any heating systems or component(s) used with a non-potable water heating appliance.

Use properly sized water heaters for spa or hot tub use.

Toxic chemicals, such as those used for boiler treatment shall not be introduced into this system.

Water supply systems may, because of such events as high line pressure, frequent cut-offs, the effects of water hammer among others, have installed devices such as pressure reducing valves, check valves, back flow preventers, etc. to control these types of problems. When these devices are not equipped with an internal by-pass, and no other measures are taken, the devices cause the water system to be closed. As water is heated, it expands (thermal expansion) and closed systems do not allow for the expansion of heated water.

The water within the water heater tank expands as it is heated and increases the pressure of the water system. If the relieving point of the water heater’s temperature-pressure relief valve is reached, the valve will relieve the excess pressure. The temperature-pressure relief valve is not intended for the constant relief of thermal expansion. This is an unacceptable condition and must be corrected. It is recommended that any devices installed which could create a closed system have a by-pass and/or the system have an expansion tank or device to relieve the pressure built by thermal expansion in the water system. Expansion tanks are available for ordering through a local plumbing contractor. Contact the local water supplier and/or a service agency for assistance in controlling these situations.

7

Image 7
Contents Residential Electric Important Definitions Safe INSTALLATION, USE and ServiceGeneral Safety Introduction Table of ContentsUprights /LOWBOYS Compacts Typical InstallationTable Tops Locating the NEW Water Heater Mixing Valve UsageFacts to Consider about the Location Insulation Blankets Installing the NEW Water HeaterWater Piping Water Piping Pressure Test TEMPERATURE- Pressure Relief Valve Valve and Pipe Insulation On Selected Models Filling the Water HeaterWiring Diagrams Wiring Temperature Adjustment Temperature RegulationOperational Conditions For Your InformationAnode ROD Inspection Periodic MaintenanceTEMPERATURE-PRESSURE Relief Valve Operation Thermostat Removal / ReplacementElement Cleaning / Replacement Page Service Drain Valve Washer ReplacementLeakage Checkpoints Problem Possible Causes Corrective Action Troubleshooting GuidelinesLowboy and Upright Electric Models Single and Dual Element Repair Parts ListCompact or Manufactured Mobile Home Electric Models Table TOP Electric Models Conditions and Exceptions Residential Electric WarrantyLimitation on Implied Warranties Service and Labor ResponsibilityClaim Procedure Installation InformationPage

ECL-30, ECT-55, ECT-40, ECT-52, ECT-80 specifications

A.O. Smith is a well-respected name in the water heating industry, renowned for its innovative products and technologies. Among its notable offerings are the EJCN-40 and ECLN-40 electric water heaters, as well as the ECS-50 model. These units exemplify A.O. Smith's commitment to efficiency, durability, and user convenience.

The A.O. Smith EJCN-40 is a reliable and efficient electric water heater with a 40-gallon capacity. It features a foam-insulated tank that ensures minimal heat loss, allowing for increased energy efficiency. This model is equipped with two heating elements, providing faster recovery times and ensuring a steady supply of hot water when needed. The EJCN-40 is designed with a user-friendly thermostat that facilitates easy temperature adjustments, enhancing overall user experience.

Similarly, the ECLN-40 shares many features with the EJCN-40 but is specifically designed for commercial applications. This model prioritizes performance and energy efficiency, making it ideal for businesses that require a dependable hot water supply. The ECLN-40 is built with an impressive heat exchanger that maximizes heat transfer, minimizing energy consumption while maintaining optimal performance.

The A.O. Smith ECS-50 stands out with a 50-gallon capacity, catering to residential and light commercial settings. This unit features a high-quality glass-lined tank, which not only provides superior insulation but also helps prevent corrosion. The ECS-50 is designed with a heavy-duty anode rod that extends the life of the tank by minimizing the risk of rusting. Its compact design allows for versatility in installation, while the integrated thermostat provides ease of use.

A.O. Smith's water heaters are equipped with advanced safety features, including automatic temperature controls and pressure relief valves, ensuring safe operation. Additionally, these models come with Energy Star certification, indicating their compliance with strict energy efficiency standards.

In summary, the A.O. Smith EJCN-40, ECLN-40, and ECS-50 water heaters combine cutting-edge technology with robust design to deliver efficient, dependable hot water solutions. With features that cater to both residential and commercial needs, A.O. Smith continues to set the standard for quality and performance in the water heating industry.