A.O. Smith EJCN-40, EJC-30 Troubleshooting Guidelines, Problem Possible Causes Corrective Action

Page 20

TROUBLESHOOTING GUIDELINES

These guidelines should be utilized by a qualified service agent.

Problem

Possible Cause(s)

Corrective Action

 

 

 

WATER LEAKS

Improperly sealed, hot or cold supply

Tighten threaded connections.

(See Leakage Checkpoints on 19)

connection, relief valve or drain valve.

 

 

 

 

 

Leakage from other appliances or water lines.

Inspect other appliances near water heater.

 

 

 

NO HOT WATER

No power to heater.

Turn on electrical switch. Check for blown

 

 

fuses or tripped breaker.

 

High Temperature Limit Switch open.

Reset. Check for source of trouble and correct.

 

 

 

 

Non-functioning upper thermostat.

Replace thermostat.

 

 

 

INSUFFICIENT HOT WATER

Non-functioning thermostats.

Replace thermostats.

 

 

 

 

Non-functioning lower element.

Replace element.

 

 

 

 

Improper calibration.

Replace thermostats.

 

 

 

 

Thermostats set too low.

Set thermostats to desired temperature.

 

 

 

 

Sediment or lime in tank.

Drain. Determine if water treatment is needed.

 

 

 

 

Heater too small for job.

Install adequate water heater.

 

 

 

 

Wrong piping connections.

Correct piping.

 

 

 

 

Leaking faucets.

Repair faucets.

 

 

 

 

Wasted hot water.

Review and reduce hot water consumption.

 

 

 

 

Long runs of exposed pipe.

Insulate piping.

 

 

 

 

Hot water piping on outside wall.

Insulate piping.

 

 

 

HIGH OPERATION COSTS

Improper Calibration.

Replace thermostats.

 

 

 

 

Thermostats set too high.

Set thermostat to desired setting.

 

 

 

 

Sediment or lime in tank.

Drain. Flush-Provide water treatment if needed.

 

 

 

 

Heater too small for job.

Install adequate heater.

 

 

 

 

Wrong piping connections.

Correct piping.

 

 

 

 

Leaking faucets.

Repair faucets.

 

 

 

 

Wasted hot water.

Review and reduce hot water consumption.

 

 

 

 

Long runs of exposed piping.

Insulate piping.

 

 

 

 

Hot water piping in exposed wall.

Insulate piping.

 

 

 

SLOW HOT WATER RECOVERY

Non-functioning upper element.

Replace element.

 

Non-functioning lower element.

Replace element.

DRIP FROM RELIEF VALVE

Excessive water pressure.

Use Pressure Reducing Valve and Pressure

 

 

Relief Valve.

 

Closed system.

See “Thermal Expansion” in the For Your

 

 

Information section.

THERMOSTAT DOES NOT SHUT OFF

Non-functioning thermostats.

Replace thermostats.

 

 

 

 

Improper calibration.

Replace thermostats.

 

 

 

WATER ODOR

Sulfides in the water.

See “Operational Conditions” in the For Your

 

 

Information section.

WATER HEATER SOUNDS

Scale accumulation on elements.

Contact dealer to clean or replace elements.

 

 

 

20

Image 20
Contents Residential Electric Safe INSTALLATION, USE and Service Important DefinitionsGeneral Safety Table of Contents IntroductionTable Tops Typical InstallationUprights /LOWBOYS Compacts Facts to Consider about the Location Mixing Valve UsageLocating the NEW Water Heater Water Piping Installing the NEW Water HeaterInsulation Blankets Water Piping Pressure Test TEMPERATURE- Pressure Relief Valve Filling the Water Heater Valve and Pipe Insulation On Selected ModelsWiring Diagrams Wiring Temperature Regulation Temperature AdjustmentFor Your Information Operational ConditionsPeriodic Maintenance TEMPERATURE-PRESSURE Relief Valve OperationThermostat Removal / Replacement Anode ROD InspectionElement Cleaning / Replacement Page Drain Valve Washer Replacement ServiceLeakage Checkpoints Troubleshooting Guidelines Problem Possible Causes Corrective ActionRepair Parts List Lowboy and Upright Electric Models Single and Dual ElementCompact or Manufactured Mobile Home Electric Models Table TOP Electric Models Residential Electric Warranty Conditions and ExceptionsService and Labor Responsibility Claim ProcedureInstallation Information Limitation on Implied WarrantiesPage