HEATER STATUS MENU

This menu displays non adjustable operational information. This menu contains more information that can be displayed on one screen of the LCD display. Use the Up & Down Buttons to navigate to the bottom of this menu.

Top of Menu

Bottom of Menu

Status

Displays the current Operating State of the control system. IE: Heating, Standby, Fault see Table 2.

Element Banks On

Displays the current number of heating element Banks the control system has energized. Each Bank of elements contains 3 heating elements.

ECO Contact

Displays the current state of the ECO high temperature limit switch contacts. The ECO switch is located inside the immersion Temperature Probe (two red wires).

Enable / Disable 1 & 2

Displays the current state, open or closed, of the two Enable/Disable circuits (J7 socket on the CCB - see wiring diagrams) provided for external supervisory controls such as building EMS (Energy Management System). Both of these Enable/Disable circuits must be closed to “enable” heating operation. If either Enable/Disable circuit is open for any reason heating operation will be “disabled.” There is a plug with two jumper wires installed from the factory in the CCB J7 socket to enable heating operation when external controls are not in use.

Service Note: If a supervisory control(s) is used to enable/disable heating operation, install field wiring between the J7 socket on the CCB and a set of “dry contacts” on the external control per all applicable building codes. This is a switching circuit only: DO NOT apply any external voltage or connect any load (IE: relay coil) to either circuit.

Element Bank On

Displays the on/off status of each Bank of heating elements. Yes = On, No = Off.

Alarm Condition

Displays the status of the user definable Alarm Output function - see Alarm Output Setup Menu. Yes = alarm condition has been met, No

=alarm condition has not been met.

Alarm Relay Output

Displays the state of the normally open contacts of the Alarm Output relay. This relay (J3 contacts on the CCB) is used for building EMS (Energy Management System) notification of operational conditions such as Fault conditions.

ECONOMY MODE SETUP MENU

This menu contains settings used to establish an “Economy Set Point” and “Economy Mode” operating periods. This control system feature can help reduce operating costs during unoccupied, low load, or peak demand periods.

Desktop Screen During Economy Mode

Economy Mode Setup Menu

Setpoint Adjustment

Adjustable user setting (2°F to 50°F - factory default is 20°F) the control system uses to calculate the “Economy Set Point.” The Economy Set Point = normal Operating Set Point minus the programmed Setpoint Adjustment value. The Economy Set Point is the water temperature the control system maintains during programmed Economy Mode time periods. “Economy Set Point” is displayed instead of “Operating Set Point” and “Economy Mode” appears beneath the current time on the Desktop Screen during Economy Mode time periods.

Current Time

Seven Day 24 hr clock. Use this menu item to set the current time and day of the week. Current day and time are not set from the factory. “Clock Not Set” will be displayed on the Desktop until the time/day has been initially set.

Heater In Economy Mode

Displays whether the control system is currently operating in Economy Mode or not.

Daily Operating Mode (Sun - Mon - Tue - Wed - Thu - Fri - Sat)

Seven daily sub menus are listed at the bottom of the Economy Mode Setup menu. There are 3 Operating Modes in each sub menu;

25

Image 25
Contents Optional Installation Operation Service Maintenance Limited WarrantyQualified Installer or Service Agency Safe INSTALLATION, USE, and ServiceImportant Definitions Ansi Z223.1 2006 SecPrecautions General Safety InformationHydrogen GAS Flammable Grounding InstructionsIntroduction Table of ContentsStandard DRE/DVE Model DifferencesBTU KW Input Hour 100 110 120 130 140Model and Rating ApprovalsFeatures and Components Surface Mount Control Models Facts to Consider About the Location Locating the NEW Water HeaterInstallation Closed Water Systems Water Line ConnectionsThermal Expansion 16. Allowable Ampacities of Insulated Conductors ElectricalHeater Circuits Electronic Control Models Amperage TABLE/OVERCURRENT ProtectionControl CIRCUIT- Electronic Control Models Wiring Diagrams Power Circuit Diagrams Electronic Control Models Nine Element Single and Three Phase Diagram Conversion to Single Phase Conversion to Three PhasePower Circuit Diagrams Surface Mount Control Models Nine Elements Single and Three Phase Diagram Conversion to Single PhaseGeneral OperationFilling the Water Heater Initial Start UPHigh Temperature Limit Controls ECO Temperature RegulationThermostat Settings Surface Mount Control Thermostat ControlsControl System Features Thermostat Settings electronic CONTROLsElectronic Control Models Operation Control System NavigationStatus Icons Description Discreet Menu Contact Information From the Desktop ScreenOperating States Temperatures MenuState Description Control System MenusDifferential Settings Temperature SettingsOperating Sequence Tank Probe OffsetHeater Status Menu Economy Mode Setup MenuSetpoint Adjustment Value Economy Mode SettingsTime Clock Settings Daily Operating Mode Settings Display Settings Menu Alarm Output Setup MenuHeater Information Menu TOP of Menu Bottom of MenuFault Occurrence Menu Current Fault / Alert MenuFault History Menu Restore Factory Defaults MenuAnode Inspection and Replacement MaintenanceRestore Factory Defaults Flushing Maintenance ScheduleSediment Removal Lime Scale RemovalChecklist Troubleshooting ChecklistReplacement Parts Not enough or no hot waterLeakage Checkpoints ONE Temperature with Circulating Loop Piping DiagramsPiping Diagrams Piping Diagrams TWO Temperature with Mixing Valve Circulating Loop Piping Diagrams Piping Diagrams Piping Diagrams Manifold Kits TWO Heaters Manifold KitsThree Heaters Four HeatersTank Warranty

Dve-52/80/120 specifications

The A.O. Smith DVE-52/80/120 is an innovative water heater designed to meet the diverse needs of both residential and commercial applications. Known for its efficiency and reliability, it stands out in the market due to its advanced features and cutting-edge technologies.

One of the main characteristics of the DVE series is its high energy efficiency, contributing to lower energy bills and a smaller carbon footprint. The units are designed with a high-efficiency burner that can achieve an energy factor (EF) rating significantly above average, ensuring more hot water is produced for less fuel consumption. This makes the A.O. Smith DVE-52/80/120 an environmentally friendly choice without sacrificing performance.

These water heaters also incorporate a unique flame rod technology that enhances the safety and reliability of the system. This feature continuously monitors the ignition of the burner and ensures an optimal combustion process, contributing to both safety and performance. Moreover, their design includes an advanced digital control system that facilitates ease of use and precise temperature management, allowing users to customize their hot water needs efficiently.

The construction of the DVE series is robust, featuring a durable glass-lined tank that resists corrosion and extends the lifespan of the heater. Insulation is another highlight, as A.O. Smith employs thick foam insulation to minimize heat loss, further improving efficiency.

The DVE-52/80/120 models also come equipped with various capacity options, catering to different household sizes and usage patterns. Whether for a small home or a larger establishment, the flexibility in capacity ensures users have consistent hot water availability according to their demands.

Additionally, the A.O. Smith DVE series is compatible with various smart home systems, making it an ideal choice for modern households seeking integrated solutions. The compatibility with Wi-Fi allows for remote monitoring and control, giving users greater convenience and peace of mind.

In summary, the A.O. Smith DVE-52/80/120 water heater is engineered with advanced technologies and reliable features that ensure optimal efficiency, safety, and performance, making it a smart investment for any hot water needs. Its blend of durability, customizable capacity, and smart technology integration positions it as a leading choice in the water heating market.