A.O. Smith TWI 35-130, TWI 45-190 service manual Chapter Target groups Description, Installation

Page 11

1.6

Notation system

This manual makes use of the following notation system:

 

 

 

 

 

Remark

 

 

Attention: important notice.

 

 

 

 

 

 

 

 

Caution

 

 

Ignoring this text may result in damage of the device.

 

 

 

 

 

 

 

 

Warning

 

 

Ignoring this text may lead to serious damage of the device and to

 

 

situations that are dangerous to people.

 

 

 

1.7

Overview of this

The table provides an overview of the content of this document.

 

document

 

Content of this document

Chapter

Target groups

Description

2.

Operation of the device

 

This chapter describes the operation of the device.

 

 

 

 

3.

Installation

 

This chapter describes the installation activities to be

 

 

 

carried out before definitely starting up the device.

 

 

 

 

4.

Conversion to another

 

Conversion to another category is not possible.

category

 

 

 

 

 

 

5.

Fill

 

This chapter describes how to fill the device.

 

 

 

 

6.

Drain

 

This chapter describes how to drain the device.

 

 

 

 

7.

Start up

 

This chapter describes how to start up the device.

 

 

 

It further describes the general heating cycle of the

 

 

 

device.

8.

Shut down

 

This chapter describes how to shut down the device for

 

 

 

a shorter or longer period.

 

 

 

 

9.

Errors

 

This chapter is mainly meant for the installation

 

 

 

engineer and the service and maintenance engineer.

 

 

 

It describes the errors of the device. These errors are

 

 

 

shown on the display. A table gives the possible cause

 

 

 

and solution. However, an end user can also find

 

 

 

additional information about the device here.

10. Maintenance

 

This chapter describes how to determine the frequency

 

 

 

for maintenance activities. Both the end user and the

 

 

 

service and maintenance engineer are responsible

 

 

 

for regular maintenance. They shall make clear

 

 

 

appointments about this. Remark If the device is not

 

 

 

regularly maintained, the warranty will become null and

 

 

 

void.

 

 

 

 

Instruction manual TWI 35-130 G/TWI 45-190 G

9

Image 11
Contents 35-130 45-190 Your installer Page Page Copyright 2007 A.O. Smith Water Products Company Page Operation of the device InstallationErrors MaintenanceWarranty certificate Table of contentAbout the device What to do when you smell gas RegulationsIntroduction Target groups IntroductionChapter Target groups Description InstallationThis chapter contains the terms of warranty Warranty certificateIntroduction This chapter will cover in the given order Operation of the deviceSecurity of the device Introduction Operation of the deviceHeating cycle 4 Fan Security of the water temperatureAir pressure switch Gas control3 T&P valve Unvented installationVented installation Packaging InstallationInstallation Working area Dimension Description TWI Dimensions of the deviceDescription Unit TWI Dimension Description TWIVented Condensation drainage Cold water sideHot water side Circulation pipingRequirements for flue gas discharge material Air supply and flue gas discharge IntroductionDevice types Practical example of concentric flue gas discharge Example Device types DescriptionConcentric connections Device Diameter Maximum length Maximum num Ber of 90 bendsSubject Description SpecificationsPractical example of parallel flue gas discharge Example Parallel connectionsDevice Diameter Maximum running length BendDevice with parallel flue gas discharge material Preparation Electrical connectionConnector block Isolating transformer Check and adjust the CO2-value Connect the mains voltageGas control Checking procedureAdjust the CO2-value Conversion to another gas category Conversion to another gas category Unvented FillFill vented installations Fill the device Fill unvented installationsDrain Drain vented InstallationsDrain unvented Start up Opening the gas valve 3.5 Connections diagramStart up Electrically isolate Shut downIntroduction You can For a short timeShut down Errors visible on the control ErrorsIntroduction Distinction is made between General errors Explosive ignition Symptom Cause Solution Remark Gas smellWater leakage Hot water Symptom Cause Solution Remark Insufficient or noLight pulses Cause Solution Remark Troubleshooting table for errors visible on the controlSee 12.2 Electrical circuit diagram Light pulses Cause Solution Remark SL3TWI Introduction Prepare maintenance MaintenanceMaintenance 11.3 Conditions Warranty certificate11.1 Warranty general 11.2 Warranty tankSmith Warranty certificate11.6 Claims 11.7 ObligationsAnnex Annex Electrical circuit diagramWiring Annex Connect IndexIndex User WarrantyPage 0308 489 R1.0

TWI 35-130, TWI 45-190 specifications

A.O. Smith TWI 35-130 and TWI 45-190 are high-efficiency water heaters designed to meet the diverse needs of residential and commercial applications. These units are part of A.O. Smith’s extensive product line, known for reliability, durability, and energy efficiency.

The TWI 35-130 model is a 35-gallon tank water heater, offering a first-hour delivery of 130 gallons. This capacity makes it suitable for households with moderate hot water demands. It features a compact design, allowing for easy installation in tighter spaces, which is ideal for urban settings. The unit operates on natural gas, promoting energy efficiency while reducing operational costs.

One of its main attributes is the advanced insulation technology that minimizes heat loss, thus enhancing overall energy efficiency. The TWI 35-130 is equipped with a state-of-the-art burner system that optimizes combustion for higher efficiency, translating to lower energy bills. Furthermore, it utilizes a dip tube that helps in delivering hot water promptly, ensuring that the demand for hot water is met swiftly.

On the other hand, the TWI 45-190 model caters to larger households or commercial settings with a 45-gallon capacity and a first-hour delivery of 190 gallons. This model also uses natural gas, but with a higher BTU rating, allowing for faster recovery rates, which is crucial during peak usage times.

Both models are designed with user-friendliness in mind, featuring intuitive controls that facilitate easy temperature adjustments and monitoring. Additionally, they incorporate safety features such as a temperature and pressure relief valve to prevent overheating and excessive pressure build-up, ensuring peace of mind for users.

Their innovative design also emphasizes longevity, with high-grade materials and protective coatings that resist corrosion and extend the lifespan of the tank. The TWI series stands out in the market not only for its performance and efficiency but also for its commitment to sustainability.

In summary, A.O. Smith's TWI 35-130 and TWI 45-190 water heaters bring together cutting-edge technology, efficiency, and reliability, making them excellent choices for both residential and commercial applications. With features designed to promote energy savings and user convenience, these models are poised to meet the hot water demands of modern life while adhering to high standards of safety and durability.