A.O. Smith SBD 30 150 warranty Heater Wiring, Single Unit Wiring Diagram

Page 10

plate. The regulator is factory adjusted to deliver gas to burner at correct water column pressure allowing for a nominal pressure drop through the controls.

The minimum gas supply pressure for input adjustment must not be less than 4.5" w.c. for natural gas.

Do not subject the combination gas valve to inlet gas pressures of more than 14.0" W.C. - natural gas. A service regulator is necessary if higher gas pressures are encountered.

Manifold gas pressure in inches of water column is 3.5.

The gas pressure specified refers to flow pressure taken at pressure tap of automatic gas valve while heater is operating.

HEATER WIRING

All electrical work must be installed in accordance with the latest version of the National Electrical Code ANSI/NFPA No. 70, must conform to all local code authority having jurisdiction. AN

ELECTRICAL GROUND IS REQUIRED TO REDUCE RISK OF ELECTRICAL SHOCK OR POSSIBLE ELECTROCUTION.

If any of the original wire as supplied with the appliance must be replaced, use only type 105°C thermoplastic or equivalent. 250°C type F must be used for the flame sensor leads and the spark ignition cable must be high voltage 250°C.

Figures shown are valid for 0-2000 ft. installations. See “HIGH ALTITUDE INSTALLATIONS” for deration requirements over 2000 ft.

FIGURE 10 - SINGLE UNIT WIRING DIAGRAM

10

Image 10
Contents Lindahl Parkway PlacetheseinstructionsadjacenttoheaterAndnotifyownertokeepforfuturereference Ashland CITY, TNRecovery Rating Capacities GPH AT Temperature Rise Shown ROUGH-IN-DIMENSIONSForeword Table of Contents Features Circulating Pump Exhaust Inducer Blower AssemblyElectronic Ignition Control Dishwashing Machine RequirementLocating the Heater Required AbilityUncrating LevelingVenting ConfinedspaceWater Potable Heating Space Heating Multiple Heater ManifoldWater Line Connections Relief ValveGAS Pressure Regulator GAS PipingPurging Length Nominal Iron Pipe Sizes Inches FeetHeater Wiring Single Unit Wiring DiagramInstallation Diagrams GeneralVertical Storage Tank and Forced Circulation Horizontal Storage Tank and Forced CirculationPage Installation DIAGRAMS-SIDE INLET/OUTLET Usage Circulating Return Line ConnectionHeater with Mixing Valve and Recirculated Sanitizing Loop TWO PRE-HEATERS with Booster Heater Horizontal Storage Tank Operation Sequence of OperationFor Your Safety Read Before Operating What to do if YOU Smell GASCheck the Ignitor Assembly Preventive MaintenanceWater Temperature Control Ignitor AssemblyChecking the Input Remote Storage Tank Temperature ControlGAS Valves Venting SystemFlushing HOT Water OdorAnode ROD Inspection DrainingDeliming Using FLO-JUG Method Tank Cleanout ProcedureDeliming Solvents Replacement Parts ServiceSystem Diagnostics Ignition Module SystemSequence of Operation Flow Chart YESComplaint Cause User Serviceman Operational ChecklistRemedy Keepthiswarrantypostedadjacenttotheheaterforfuturereference ServiceandrepairexpensesClaimprocedure TankLindahl Parkway Ashland City, TN Phone 800-821-2017 Fax

SBD 30 150 specifications

The A.O. Smith SBD 30 150 is a high-efficiency water heater designed to meet the hot water needs of residential applications. Renowned for its reliability and performance, this model exemplifies A.O. Smith's commitment to innovative technology and energy efficiency.

One of the standout features of the A.O. Smith SBD 30 150 is its capacity. With a 30-gallon tank, it is ideally suited for small to medium-sized households. This makes it an excellent choice for families or individuals who require a steady supply of hot water for various applications like bathing, cooking, and cleaning.

The SBD 30 150 is equipped with a powerful, efficient heating element that delivers quick recovery rates. This means that users can expect hot water when they need it without long waiting times. The advanced insulation technology employed in its design reduces heat loss, allowing the unit to maintain a steady temperature and operate at optimal efficiency.

Energy efficiency is a key characteristic of the A.O. Smith SBD series. It features Energy Star certification, demonstrating its ability to provide hot water while minimizing energy consumption. Users can enjoy the dual benefit of reduced energy bills and a smaller carbon footprint. This model is particularly appealing to eco-conscious consumers looking to integrate green technologies into their homes.

In terms of durability, the SBD 30 150 is built with high-quality materials designed to withstand the test of time. Its glass-lined tank provides excellent corrosion resistance, which is essential for extending the lifespan of the unit. Additionally, the heater includes a durable anode rod, which serves to protect the tank from galvanic corrosion, further enhancing its longevity.

Convenience features are also notable in this model. It comes with a thermostat that allows for easy temperature control, enabling users to set the preferred hot water temperature without hassle. Moreover, the compact design of the SBD 30 150 makes it easy to install in various settings, whether it’s a small utility area or a basement.

In conclusion, the A.O. Smith SBD 30 150 water heater stands out as a practical and efficient solution for anyone in need of reliable hot water. With its impressive features, energy-saving technologies, and robust design, it is a smart investment for long-lasting performance and comfort in everyday life.