A.O. Smith SBD 30 150 warranty Table of Contents

Page 3

TABLE OF CONTENTS

 

 

Page

ROUGH-IN-DIMENSIONS

2

FOREWORD

2

GENERAL SAFETY INFORMATION

3

Precautions

3

Grounding Instructions

3

Chemical Vapor Corrosion

3

Improper Combustion

3-4

Extended Non-Use

4

Insulation Blankets

4

High Altitude Installation

4

FEATURES

4

Self-Cleaning Hydro-Cannon

4

High Limit Switch

4-5

Electronic Ignition Control

5

Exhaust Inducer (Blower Assy.)

5

Circulating Pump

5

Dishwashing Machine Requirement

5

INSTALLATION INSTRUCTIONS

6

Required Ability

6

Uncrating

6

Locating The Heater

6

Levelling

6

Clearances

6

Air Requirements

6-7

Venting

7-8

Multiple Heater Manifold

8

Water Line Connections

8

Water (Potable) Heating and Space Heating

8

Thermometers (Not Supplied)

8

Relief Valve

8

Gas Piping

9

Gas Pressure Regulator

9-10

Heater Wiring

10

 

Page

INSTALLATION DIAGRAMS

11-17

OPERATION

18

General

18

SEQUENCE OF OPERATION

18

Lighting and Operation

19

Water Temperature Control

20

PREVENTIVE MAINTENANCE

20

Check The Ignitor Assembly

20

Ignitor Assembly

20

Main Burner

20-21

Gas Valves

21

Checking The Input

21

Venting System

21

Remote Storage Tank Temperature Control

21

Relief Valve

22

Hot Water Odor

22

Anode Rod Inspection

22

Flushing

22

Draining

22

Recommended Procedure For Periodic

 

Removal of Lime Deposits From Tank Type

 

Commercial Water Heaters

22-23

Deliming Solvents

23

Tank Cleanout Procedures

23-24

Ignition Module System

24

System Diagnostics

24

SERVICE

24

Electrical Servicing

24

Replacement Parts

24

Sequence of Operation Flow Chart

25

Operational Checklist

26

Limited Warranty

27

GENERAL SAFETY INFORMATION

PRECAUTIONS

DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

IF THE UNIT IS EXPOSED TO THE FOLLOWING, DO NOT OPERATE HEATER UNTIL ALL CORRECTIVE STEPS HAVE BEEN MADE BY A QUALIFIED SERVICEMAN.

1.EXTERNAL FIRE.

2.DAMAGE.

3.FIRING WITHOUT WATER.

4.SOOTING

GROUNDING INSTRUCTIONS

This water heater must be grounded in accordance with the National Electric Code and/or local codes. These must be followed in all cases.

This water heater must be connected to a grounded metal, permanent wiring system; or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the water heater, see Figure 9.

CHEMICAL VAPOR CORROSION

WARNING

CORROSION OF THE FLUEWAYS AND VENT SYSTEM MAY OCCUR IF AIR FOR COMBUSTION CONTAINS CERTAIN CHEMICAL VAPORS. SUCH CORROSION MAY RESULT IN FAILURE AND RISK OFASPHYXIATION.

Spray can propellants, cleaning solvents, refrigerator and air conditioning refrigerants, swimming pool chemicals, calcium and sodium chloride (water softener salt), waxes, and process chemicals and typical compounds which are potentially corrosive. Do not store products of this sort near the heater. Also, air which is brought in contact with a the heater should not contain any of these chemicals. If necessary, uncontaminated air should be obtained from remote or outside sources. The limited warranty is voided when failure of water heater is due to a corrosive atmosphere. (Refer to the limited warranty for complete terms and conditions.

IMPROPER COMBUSTION

WARNING

ATTICAND/OR EXHAUST FANS OPERATING ON THE PREMISES WITH AWATER HEATER CAN RESULT IN CARBON MONOXIDE POISONINGAND DEATH.

3

Image 3
Contents Ashland CITY, TN PlacetheseinstructionsadjacenttoheaterAndnotifyownertokeepforfuturereference Lindahl ParkwayROUGH-IN-DIMENSIONS Recovery Rating Capacities GPH AT Temperature Rise ShownForeword Table of Contents Features Dishwashing Machine Requirement Exhaust Inducer Blower AssemblyElectronic Ignition Control Circulating PumpLeveling Required AbilityUncrating Locating the HeaterConfinedspace VentingRelief Valve Multiple Heater ManifoldWater Line Connections Water Potable Heating Space HeatingLength Nominal Iron Pipe Sizes Inches Feet GAS PipingPurging GAS Pressure RegulatorSingle Unit Wiring Diagram Heater WiringGeneral Installation DiagramsHorizontal Storage Tank and Forced Circulation Vertical Storage Tank and Forced CirculationPage Circulating Return Line Connection Installation DIAGRAMS-SIDE INLET/OUTLET UsageHeater with Mixing Valve and Recirculated Sanitizing Loop TWO PRE-HEATERS with Booster Heater Horizontal Storage Tank Sequence of Operation OperationWhat to do if YOU Smell GAS For Your Safety Read Before OperatingIgnitor Assembly Preventive MaintenanceWater Temperature Control Check the Ignitor AssemblyVenting System Remote Storage Tank Temperature ControlGAS Valves Checking the InputDraining HOT Water OdorAnode ROD Inspection FlushingTank Cleanout Procedure Deliming Using FLO-JUG MethodDeliming Solvents Ignition Module System ServiceSystem Diagnostics Replacement PartsYES Sequence of Operation Flow ChartOperational Checklist Complaint Cause User ServicemanRemedy Tank ServiceandrepairexpensesClaimprocedure KeepthiswarrantypostedadjacenttotheheaterforfuturereferenceLindahl Parkway Ashland City, TN Phone 800-821-2017 Fax

SBD 30 150 specifications

The A.O. Smith SBD 30 150 is a high-efficiency water heater designed to meet the hot water needs of residential applications. Renowned for its reliability and performance, this model exemplifies A.O. Smith's commitment to innovative technology and energy efficiency.

One of the standout features of the A.O. Smith SBD 30 150 is its capacity. With a 30-gallon tank, it is ideally suited for small to medium-sized households. This makes it an excellent choice for families or individuals who require a steady supply of hot water for various applications like bathing, cooking, and cleaning.

The SBD 30 150 is equipped with a powerful, efficient heating element that delivers quick recovery rates. This means that users can expect hot water when they need it without long waiting times. The advanced insulation technology employed in its design reduces heat loss, allowing the unit to maintain a steady temperature and operate at optimal efficiency.

Energy efficiency is a key characteristic of the A.O. Smith SBD series. It features Energy Star certification, demonstrating its ability to provide hot water while minimizing energy consumption. Users can enjoy the dual benefit of reduced energy bills and a smaller carbon footprint. This model is particularly appealing to eco-conscious consumers looking to integrate green technologies into their homes.

In terms of durability, the SBD 30 150 is built with high-quality materials designed to withstand the test of time. Its glass-lined tank provides excellent corrosion resistance, which is essential for extending the lifespan of the unit. Additionally, the heater includes a durable anode rod, which serves to protect the tank from galvanic corrosion, further enhancing its longevity.

Convenience features are also notable in this model. It comes with a thermostat that allows for easy temperature control, enabling users to set the preferred hot water temperature without hassle. Moreover, the compact design of the SBD 30 150 makes it easy to install in various settings, whether it’s a small utility area or a basement.

In conclusion, the A.O. Smith SBD 30 150 water heater stands out as a practical and efficient solution for anyone in need of reliable hot water. With its impressive features, energy-saving technologies, and robust design, it is a smart investment for long-lasting performance and comfort in everyday life.