A.O. Smith GPDX External Damage, Chemical Vapor Corrosion, Extended NON-USE Periods, General

Page 3

GENERAL SAFETY INFORMATION

EXTERNAL DAMAGE

Do not operate the water heater until it has been fully checked out by a qualified technician, if the water heater:

Has been exposed to fire or damage.

Displays evidence of sooting.

Produces steam or unusually hot water.

If the water heater has been flooded it must be replaced.

CHEMICAL VAPOR CORROSION

WARNING

CORROSION OF THE FLUEWAYS AND VENT SYSTEM MAY OCCUR IF AIR FOR COMBUSTION CONTAINS CERTAIN CHEMICAL VAPORS WHICH WILL BREAK DOWN INTO ACIDS AT HIGH TEMPERATURE. SUCH CORROSION MAY RESULT IN FAILURE AND RISK OF ASPHYXIATION.

Spray can propellants, cleaning solvents, refrigerator and air conditioning refrigerants, swimming pool chemicals, calcium and sodium chloride (water softener salt), waxes, and process chemicals are typical compounds which are potentially corrosive.

Do not store products of this sort near the heater. Also, air which is brought in contact with the heater should not contain any of these chemicals. If necessary, uncontaminated air should be obtained from remote or outside sources. The limited warranty is voided when failure of water heater is due to a corrosive atmosphere. (Refer to the limited warranty for complete terms and conditions).

EXTENDED NON-USE PERIODS

WARNING

HYDROGEN GAS CAN BE PRODUCED IN A HOT WATER SYSTEM SERVED BY THIS HEATER THAT HAS NOT BEEN USED FOR A LONG PERIOD OF TIME (GENERALLY TWO WEEKS OR MORE). HYDROGEN GAS IS EXTREMELY FLAMMABLE. To reduce the risk of injury under these conditions, it is recommended that the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance connected to the hot water system. If hydrogen is present, there will probably be an unusual sound such as air escaping through the pipe as the water begins to flow. THERE SHOULD BE NO SMOKING OR OPEN FLAME NEAR THE FAUCET AT THE TIME IT IS OPEN.

INSULATION BLANKETS

Insulation blankets available to the general public for external use on gas water heaters are not necessary with A.O. Smith products. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank water heaters. Your A. O. Smith water heater meets or exceeds the National Appliance Energy Conservation Act standards with respect to insulation and standby loss requirements, making an insulation blanket unnecessary.

WARNING

Should you choose to apply an insulation blanket to this heater, you should follow these instructions, see Figure 1 for identification of components mentioned below. Failure to follow these instructions can restrict the air flow required for proper combustion, potentially resulting in fire, asphyxiation, serious personal injury or death.

Do not cover the outer door, thermostat or temperature & pressure relief valve.

Do not cover the instruction manual. Keep it on the side of the water heater or nearby for future reference.

Do obtain new warning and instruction labels from A.O. Smith for placement on the blanket directly over the existing labels.

LIQUID PETROLEUM MODELS

WARNING

Water heaters for propane or liquefied petroleum gas (LPG) are different from natural gas models. A natural gas heater will not function safely on LP gas and no attempt should be made to convert a heater from natural gas to LP gas.

LP gas must be used with great caution. It is highly explosive and heavier than air. It collects first in the low areas making its odor difficult to detect at nose level. If LP gas is present or even suspected, do not attempt to find the cause yourself. Go to a neighbor’s house, leaving your doors open to ventilate the house, then call your gas supplier or service agent. Keep area clear until a service call has been made.

At times you may not be able to smell an LP gas leak. One cause is odor fade, which is a loss of the chemical odorant that gives LP gas its distinctive smell. Another cause can be your physical condition, such as having a cold or a diminishing sense of smell with age. For these reasons, the use of a propane gas detector is recommended.

IF YOU EXPERIENCE AN OUT-OF-GAS SITUATION, DO NOT TRY TO RELIGHT APPLIANCES YOURSELF. Ask your LP delivery person to relight pilots for you. Only trained LP professionals should conduct the required safety checks in accordance with industry standards.

INSTALLATION

REQUIRED ABILITY

INSTALLATION OR SERVICE OF THIS WATER HEATER REQUIRES ABILITY EQUIVALENT TO THAT OF A LICENSED TRADESMAN IN THE FIELD INVOLVED. PLUMBING, AIR SUPPLY, VENTING AND GAS SUPPLY ARE REQUIRED.

GENERAL

The installation must conform to these instructions and the local code authority having jurisdiction. In the absence of local codes, the installation must comply with the current editions of the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and the National Electrical Code, NFPA 70. The former is available from the

3

Image 3
Contents Residential Replacement Parts and Deliming Products With HOT Surface IgnitionGAS Model Insulation Blankets External DamageChemical Vapor Corrosion Extended NON-USE PeriodsLocation of Heater Water ConnectionsWater Potable Heating Space Heating Closed Water System GAS ConnectionsVenting Venting Through an Outside Wall Clearances Combustion AIR and ExhaustWire Fence Venting Through AN Outside WallVenting Through Roof Clearances Venting System Example Installation For ALL Models Vent piping can be installed as followsDIA. Vents Number of 90 DEG Movement Complete Joint SET Approximate Setting Time for 2-1/2 to 4 Pipe JointsVent Pipe Separation Cementing PVC, ABS or Cpvc Pipe and FittingsElbows WiringConnecting Vent to Blower Venting Through a RoofOptional Field Installed Wiring Do not TRY to Light the Burner by Hand What to do if YOU Smell GASFilling Temperature RegulationControl Sequence HOT Surface Direct Ignition High Altitude InstallationVenting Manual Reset Switch Water Heating Ignition SequenceVenting System High Temperature Limit SwitchPower Venter Maintenance Main BurnerThermostat and GAS Supply Check Service and RepairWater Heater Control LED Status Problem Solution Trouble ShootingCondensation HOT WaterVent Pipe TOO HOT Yellow FlameLimited Residential GAS Warranty Southeast Parkway FRANKLIN, TN

GPDT, GPDH, GPDX specifications

A.O. Smith is a renowned leader in the manufacturing of water heating solutions, and its series of gas water heaters, including the GPDT, GPDH, and GPDX models, are emblematic of the company’s commitment to innovation, efficiency, and reliability.

The A.O. Smith GPDT series is characterized by its high energy efficiency and robust design. With a 40-gallon capacity, it utilizes a 0.67 energy factor, making it an ideal choice for both residential and light commercial applications. This model features a unique combustion system that minimizes emissions while maximizing hot water output. Equipped with a powered draft system, the GPDT series effectively vents combustion gases, improving air quality and lowering operational costs.

In contrast, the GPDH series is particularly notable for its compatibility with high-efficiency gas appliances. It employs a direct vent system, allowing for versatile installation options. The GPDH models also include advanced diagnostics and a LED display that simplifies monitoring and maintenance. With an enhanced insulation design, these heaters minimize heat loss, effectively optimizing performance and energy savings.

The GPDX series capitalizes on cutting-edge technologies to provide superior performance. With capacities ranging from 30 to 50 gallons, these water heaters are designed to meet varying needs. The GPDX is equipped with a dual-purpose valve that offers superior temperature control and safety features, ensuring user convenience and peace of mind. Its intuitive interface allows users to easily set their desired water temperature and monitor performance metrics.

One of the key characteristics that unify the GPDT, GPDH, and GPDX models is their commitment to durability. A.O. Smith incorporates high-quality materials and innovative engineering processes to enhance the longevity of their products. Each model features an impressive warranty, demonstrating the company’s confidence in their craftsmanship.

In conclusion, A.O. Smith's GPDT, GPDH, and GPDX gas water heater series offer a blend of efficiency, performance, and innovation. These models are equipped with advanced technologies designed to provide users with reliable hot water solutions while minimizing energy consumption. With their robust build, user-friendly features, and impressive warranties, A.O. Smith continues to be a top choice for those seeking dependable gas water heating solutions.