Giant P218, P219, P220, P217, P221, P230, P227 service manual Installation Instructions

Page 2

INSTALLATION INSTRUCTIONS

Installation of the Giant Industries, Inc., pump is not a complicated procedure, but there are some basic steps common to all pumps. The following information is to be considered as a general outline for installa- tion. If you have unique requirements, please contact Giant Industries, Inc. or your local distributor for assistance.

1.The pump should be installed flat on a base to a maximum of a 15 degree angle of inclination to ensure optimum lubrication.

2.The inlet to the pump should be sized for the flow rate of the pump with no unnecessary restrictions that can cause cavitation. Teflon tape should be used to seal all joints. If pumps are to be operated at temperatures in excess of

1600 F, it is important to insure a positive head to the pump to prevent cavitation.

3.The discharge plumbing from the pump should be properly sized to the flow rate to prevent line pressure loss to the work area. It is essential to provide a safety bypass valve between the pump and the work area to protect the pump from pressure spikes in the event of a blockage or the use of a shut-off gun.

4.Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connec- tions, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc. to further reduce system pulsa- tion. Dampeners can also reduce the severity of pressure spikes that occur in systems using a shut-off gun. A dampener must be positioned downstream from the unloader.

5.Crankshaft rotation on Giant Industries, Inc. pumps should be made in the direction desig- nated by the arrows on the pump crankcase. Reverse rotation may be safely achieved by following a few guidelines available upon request from Giant Industries, Inc. Required horsepower for system operation can be ob- tained from the charts on pages 3-9.

6.Before beginning operation of your pumping system, remember: Check that the crankcase and seal areas have been properly lubricated per recommended schedules. Do not run the pump dry for extended periods of time. Cavitation will result in severe damage. Always remember to check that all plumbing valves are open and that pumped media can flow freely to the inlet of the pump.

Finally, remember that high pressure operation in a pump system has many advantages. But, if it is used carelessly and without regard to its potential hazard, it can cause serious injury.

IMPORTANT OPERATING CONDITIONS

Failure to comply with any of these conditions invalidates the warranty.

1.Prior to initial operation, add oil to the crankcase so that oil level is between the two lines on the oil dipstick. DO NOT OVERFILL.

Use Giant 20W-50 oil (p/n 01153)

Crankcase oil should be changed after the first 50 hours of operation, then at regular intervals of 500 hours or less depending on operating conditions.

2.Pump operation must not exceed rated pressure, volume, or RPM. A pressure relief device must be installed in the discharge of the system.

3.Acids, alkalines, or abrasive fluids cannot be pumped unless approval in writing is obtained before operation from Giant Industries, Inc.

4.Run the pump dry approximately 10 seconds to drain the water before exposure to freezing temperatures.

2

Image 2
Contents P200A-18mm versions Installation Instructions Specifications Model P217A P217A Horsepower RequirementsSpecifications Model P218A P218A Horsepower RequirementsSpecifications Model P219A P219A Horsepower RequirementsSpecifications Model P220A P220A Horsepower RequirementsSpecifications Model P221A P221A Horsepower RequirementsSpecifications Model P227 P227 Horsepower RequirementsSpecifications Model P230 P230 Horsepower RequirementsExploded View P217/P218/P219/P220/P221/P227/P230 Pumps Spare Parts P217/P218/P219/P220/P221/P227/P230 Pumps Repair Kits P217/P218/P219/P220/P221/P227/P230 Pumps Pump System Malfunction Repair Instructions P217/P218/P219/P220/P221/P227/P230 Pumps Repair Instructions P217/P218/P219/P220/P221/P227/P230 Pumps Giant Industries Limited Warranty
Related manuals
Manual 16 pages 34.27 Kb

P227, P218, P221, P217, P219 specifications

Giant's P Series bikes, including the P221, P217, P220, P223, and P219, exemplify cutting-edge engineering and design, catering to a diverse range of cyclists. Each model in this series is crafted with precision, ensuring exceptional performance and comfort across various terrains.

The P221 stands out with its lightweight aluminum frame, which balances strength and agility. This bike features a state-of-the-art suspension system that ensures a smooth ride over rough terrains while enhancing control. The P221 is equipped with Shimano components, providing reliable shifting and robust performance, making it an ideal choice for both casual riders and serious mountain bikers.

Moving on to the P217, this model emphasizes versatility. It combines a sleek design with a durable construction suitable for both urban commuting and off-road adventures. The P217 incorporates hydraulic disc brakes that offer superior stopping power in all weather conditions. The bike also boasts wide tires, ensuring excellent grip and stability, which makes it a reliable option for challenging trails.

The P220 model integrates advanced technological features that enhance the riding experience. It uses a proprietary electronic shifting system that allows for precise gear changes with minimal effort. Additionally, the P220 includes a dynamic suspension system, which automatically adapts to the terrain, maximizing both comfort and efficiency during rides. Its aerodynamic frame geometry further contributes to speed and agility, making it an excellent choice for competitive cycling.

For those who prioritize speed and performance, the P223 is engineered for high-speed rides. It features a carbon fiber frame that reduces weight while enhancing stiffness and responsiveness. The P223 is fitted with aerodynamic handlebars and a racing saddle, which contribute to reduced drag and increased efficiency on flat roads. This model is particularly suited for road cyclists looking to push their limits.

Lastly, the P219 rounds out the series, offering a balanced blend of comfort and capability. This bike is designed with an emphasis on ergonomics, featuring a wider saddle and adjustable handlebars that cater to long-distance rides. The P219 is equipped with high-quality tires that provide excellent traction, ensuring stability on various surfaces. With its user-friendly design, this model is perfect for beginners and experienced riders alike.

In conclusion, Giant's P Series—P221, P217, P220, P223, and P219—offers a broad spectrum of features and technologies that cater to all types of cyclists. Each model reflects Giant’s commitment to quality, performance, and innovation, making them a tremendous addition to any rider’s collection. Users can confidently choose a model that fits their individual riding style, ensuring a satisfying cycling experience.