Giant GP8045 Valve Inspection and Repair, To Check Seals and Plunger Pipe

Page 8

GP8045/GP8048 PUMP REPAIR INSTRUCTIONS

Valve Inspection and Repair

1) Remove bolts (58).

2) Remove discharge

3) Take out pressure springs

 

casing (50B) up and away.

(57A). Pull out assembled

 

 

valves (51 & 52) with fitting tool.

To Check Seals and Plunger Pipe

5)Remove hexagon nuts (49A) and valve casing together with seal case (38) from crankcase (1). If neces- sary, carefully tap the valve casing (50) past the centering stud (50A) using a rubber hammer. IMPORTANT! If necessary, support the valve casing by resting it on wooden blocks or by using a pulley.

4)The spring tension cap (51A, 52A) is screwed together with the valve seat (51B or 52B). Screw off spring tension cap. Takeout springs (51E, 52E) and valve plate (51C, 52C). Check sealing surfaces and O-rings (51D, 52D). Replace worn parts. Coat threads of valve seat with silicon grease or molycote anti- seize Cu-7439 when reassembling. Before refitting the valves, clean the sealing surfaces in the casing and check for any damage. Tighten caps (58) at 133 Ft-lbs; check torque tension after 8-10 operating hours.

6)Remove tension screw (36C) and take seal sleeve (39) together with all mounted parts out of the drive. Pull plunger pipe out of the seal assembly and check for any damage. Carefully, remove seal rings (40) and sleeves (42) with a screw driver.

8

Image 8
Contents Models GP8045 / GP8048 Installation Instructions Important Operating ConditionsSpecifications Model GP8045 Special NoteExploded View -- GP8045 / GP8048 Part Description Qty Specifications Model GP8048 Horsepower RatingsGP8000 Trouble Shooting GP8045/GP8048 Pump Repair KitsValve Inspection and Repair To Check Seals and Plunger PipeReplacing Valve Casing Remove the connecting rod screws To Dismantle Crankcase GearDimensions GP8045 / GP8048 mm Giant Industries Limited Warranty