Graco 306981AD important safety instructions Starting and Adjusting the Pump

Page 10

Operation

Starting and Adjusting the Pump

See Fig. 2 on page 7. Be sure the air regulator (E) and bleed-type master air valve (D) are closed. Do not install the spray tip yet!

Connect a suction hose (N) to the pump’s fluid inlet. Hold a metal part of the spray gun (M) firmly to the side of a grounded metal pail and hold the trigger open. Then open the pump’s bleed-type master air valve (D). Now slowly open the air regulator until the pump starts, about 40 psi (0.3 MPa, 3 bar).

Cycle the pump slowly until all the air is pushed out and the pump and hoses are fully primed. Release the spray gun trigger and lock the trigger safety. The pump should stall against pressure when the trigger is re- leased.

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 9.

Relieve the pressure. Install the spray tip as explained in your separate gun manual.

With the pump and lines primed, and with adequate air pressure and volume supplied, the pump will start and stop as the spray gun is opened and closed. In a circu- lating system, the pump will run continuously and will speed up or slow down as supply demands until the air supply is shut off.

Use an adequately sized air regulator (E) to control the pump speed and the fluid pressure. Always use the lowest air pressure necessary to get the desired re- sults. Higher pressures waste fluid and cause prema- ture wear of the pump packings and spray tip.

WARNING

COMPONENT RUPTURE HAZARD To reduce the risk of overpressurizing

your system, which could cause compo- nent rupture and serious injury, never

exceed the Maximum Air Input Pressure marked on the pump. Refer to the Technical Data on page 20.

CAUTION

Do not allow the pump to run dry. It will quickly accelerate to a high speed, causing damage. If your pump is running too fast, stop it immediately and check the fluid supply. If the container is empty and air has been pumped into the lines, refill the con- tainer and prime the pump and the lines, or flush and leave it filled with a compatible solvent. Eliminate all air from the fluid system.

A pump runaway valve (B), which shuts off the air supply to the pump if the pump accelerates beyond the pre-set speed, is available. See Fig. 2 on page

7.Contact your Graco distributor for further infor- mation.

10 306981

Image 10
Contents Ratio President Pumps Instructions-Parts ListRatio Monark Pumps Table of Contents SymbolsSkin Injection Hazard Moving Parts HazardFire and Explosion Hazard Toxic Fluid HazardGeneral Information InstallationPrepare the Operator Grounding Fluid Line Accessories Mounting AccessoriesAir Line Accessories Air and Fluid Hoses Model 223586 Shown 306981 Packing Nut Pressure Relief ProcedureOperation Flush the Pump Before First UseStarting and Adjusting the Pump Flushing Shutdown and Care of the PumpExplosion Hazard on Troubleshooting Problem Cause SolutionReconnecting the Displacement Pump ServiceDisconnecting the Displacement Pump Under Disconnecting the Displacement PumpDisassembly Displacement Pump ServiceReassembly Throat Packing Detail Model 221075, Series C PartsDescription Qty Model 243664, Series a Model 223586, Series B Part Description Qty02506 Description Qty No. Part No PackingCategory Data Technical DataSound Power Levels dBa Input Air Pressures at 15 cycles per minuteRatio President Pumps Ratio Monark PumpPage Dimensions Mounting Hole LayoutGraco Information Graco Standard WarrantyToll Free