Gardena 6500 SP manual Operation, Automatic operation, Plug the power cable 1 into a mains socket

Page 5

GB

Connecting the hose: The universal fitting 7 allows you to connect all the hoses listed in the previous table.

1.Cut off nipples of the universal fitting 7, which are not needed, to match the hose connection.

2.Screw the universal fitting 7 onto the pump.

3. Connect the hose to the universal fitting 7.

We recommend that you secure 38 mm (1 1/2 ) and 25 mm (1) hoses additionally with a GARDENA Hose Clip Art. No. 1591.

7

Only for 13 mm (1/2) hose:

The universal fitting 7 can also be equipped with a GARDENA Regulator Valve Art. No. 977 so that the contents of the out- let line do not flow back through the pump after pumping. The Regulator Valve can be ordered from your GARDENA dealer.

4. Operation

Automatic operation:

1

2

3

5

To ensure that the pump draws the water out, the water to be drained must be at least 10 cm deep.

The float switch 5 turns the pump on automatically when the water level exceeds the cut-in height and the water is pumped out.

The float switch 5 turns the pump off again as soon as the water level falls below the cut-out height.

1.Stand the pump on a firm surface

– or –

use a rope attached through the bore hole in the carrying handle 2 to immerse the pump in a well or shaft.

During automatic operation, ensure that the float switch 5 can move freely.

2. Plug the power cable 1 into a mains socket.

Adjusting the Cut-in and Cut-out Height:

The maximum cut-in height and minimum cut-out height (see 8. Technical Data) can be adjusted.

vPush the cable of the float switch 5 into the float switch lock 3. Do not select a cable length that is too long or short to ensure that the float switch can turn on and off properly.

The higher the opening of the float switch lock 3, the higher the cut-in and cut-out height.

The shorter the length of cable between the float switch 5 and the float switch lock 3, the lower the cut-in height and the higher the cut-out height.

The cable length between the float switch 5 and the float switch lock 3 must always be at least 10 cm.

14

Image 5
Contents Gardena Applications Range of Your Gardena Dirty Water Pump ContentsIntended use Liquids to be pumpedFor Your Safety Thermal motor protector Initial OperationAutomatic deaerating ValveAdjusting the Cut-in and Cut-out Height Plug the power cable 1 into a mains socketOperation Automatic operationFlushing the pump CleaningTrouble-Shooting Storage Technical DataPerformance characteristics ServiceWarranty Cut-in / Cut-out heightProduct Liability Bulgaria