Reliable I500A, i500B instruction manual Have poured too much water into it

Page 14

TROUBLESHOOTING

PROBLEM

 

EXPLANATION

Does

It may happen that, while filling the

steam go

tank, some water overfills the cap

out from

and flows inside the boiler wetting

the boiler?

the insulating material

Does the

1)

While filling the tank you may

nozzle or

have poured too much water into it.

gun leak

 

 

water

 

 

mixed with

 

 

steam?

 

 

There is

1)

The steam knob (where

no steam

supplied) might be closed

coming out

 

 

of the

2)

The foot pedal is not plugged in

nozzle or

(i500B)

gun?

 

 

 

3)

The boiler switch might be off

 

4)

The water might be used up.

Does the

Some dirty might have gone into

steam leak

the tank with the water and it is

dirty

given off from the iron.

water?

 

 

SOLUTION

In order to solve the problem, we suggest using the machine as usual so that the insulating material dries up in about one hour through the heat of the machine. In case you still have this problem after one working hour, please contact the service centre.

1) The problem will go on until the excess water is emptied. Keep the steam button depressed until the water in the tank is at the correct level.

1)Open the steam knob anticlockwise.

2)Plug the 4-pin receptacle into the boiler.

3)After the boiler switch comes on, wait for

10 minutes so the boiler produces steam.

4)Fill it following the instructions carefully. Fill the empty tank with 1 liter of water, screw the cap up, shake it, unscrew the cap and empty the tank. Repeat the action until the water is cleaned. We do not recommend the use of any additive to pour in the tank. Before ironing again spray some steam on a cloth until clean steam comes out.

Image 14
Contents I500 Page Components Technical Data Troubleshooting Problem ExplanationI500 Spare Parts Lists Wiring 16AWG I500 Parts Drawing I500 Wiring Diagram Page Component List I500B Components Technical Data Have poured too much water into it I500A Spare Parts Lists I500A Parts Drawing I500B Spare Parts Lists I500B Parts Drawing I500A/B Wiring Diagram Water Level Stick Page Page

i500, I500A, i500B specifications

The Reliable i500B, i500A, and i500 are a series of high-performance commercial steam boilers that stand out in the industry for their innovative design, efficiency, and reliability. These models are tailored for users who require robust solutions for various steam needs, from industrial applications to food processing and cleaning operations.

The i500B model is known for its powerful output, designed to handle high-demand scenarios. With a high efficiency that reaches up to 90%, the i500B offers optimal fuel consumption while providing superior steam quality. Its advanced burner technology ensures a clean burn, reducing emissions and operational costs. Additionally, the unit features an intelligent control system that simplifies operation, allowing users to optimize performance and maintain precise steam temperature and pressure.

Moving to the i500A, this model is particularly recognized for its compact design without compromising on performance. It is ideal for smaller spaces or applications where footprint is a concern. The i500A boasts features such as a high-capacity feed water system and robust insulation, resulting in reduced heat loss and improved efficiency. This model also integrates a user-friendly control panel that facilitates real-time monitoring and adjustments, making it easier for operators to manage the steam supply.

Lastly, the base i500 model holds its ground as a versatile choice for a variety of applications. It combines reliability with an economical approach to steam generation. The i500 is engineered with durable materials and corrosion-resistant components, ensuring a long service life with minimal maintenance. Its integrated safety features and automatic shut-off systems enhance operational reliability, making it a preferred option for facilities that prioritize safety.

All three models utilize state-of-the-art technologies such as modulating burners, advanced heat recovery systems, and comprehensive diagnostic capabilities. These features contribute to their ability to adapt to fluctuating steam demands efficiently, ensuring consistent performance.

In summary, the Reliable i500B, i500A, and i500 series represent some of the best options available for efficient and reliable steam generation. Their advanced technologies and thoughtful design cater to a wide range of industrial needs, ensuring that users benefit from both performance and economy. Whether in a large manufacturing plant or a smaller workshop, these models provide effective steam solutions that stand the test of time.