Reliable i500B, I500A instruction manual

Page 10

USER INSTRUCTIONS i500A/B

Thank you for purchasing the Reliable™ i500A/B steam cleaner. Please follow the instructions carefully. With proper care and maintenance, your steamer will provide years of dependable service.

1.Unscrew the security cap and fill the steamer with a maximum of 2 Liters of water. If you have ordered the i500A with the nozzle and foot pedal, screw the nozzle into the steam fitting and plug in the 4- pin receptacle for the electronic foot pedal. If you have the ordered the i500B with steam gun connect the same way using the quick disconnect for the steam hose.

2.Plug the steam generator into the main power supply.

3.Switch on the steam generator by pressing the button "boiler" and the steam by pressing the "steam" button.

4.Wait until the pressure reaches 3.5-bar (50 lbs). This will take approximately 15 minutes.

5.Press the foot pedal or the (red) steam button on the steam gun and regulate the desired steam quantity by turning the valve handle situated behind the solenoid valve on the steam generator.

6.If you notice a decrease in steam pressure when you first use the steamer, this is because the tank is full of air. In order to have plenty of steam (after you have depressed the foot pedal or steam gun) wait until the pressure goes back up to the maximum level before you begin.

7.If during use the steam flow ceases and the low water button lights up, it means that there's no more water in the steam generator. In order to start steaming again, switch off the "boiler" button, slowly unscrew the security cap, verifying before unscrewing it completely that there is no more steam in the nozzle or steam gun. To verify this, just press the foot pedal or the red steam button situated on the gun. Take the plug off the steam generator and fill the steamer with water to the required level.

IMPORTANT

When you are finished using the boiler for the day, unscrew the fill cap one- turn on the unit to release the steam/air from the tank. This will eliminate the vacuum that may cause damage to the pressure gauge.

Image 10
Contents I500 Page Components Technical Data Troubleshooting Problem ExplanationI500 Spare Parts Lists Wiring 16AWG I500 Parts Drawing I500 Wiring Diagram Page Component List I500B Components Technical Data Have poured too much water into it I500A Spare Parts Lists I500A Parts Drawing I500B Spare Parts Lists I500B Parts Drawing I500A/B Wiring Diagram Water Level Stick Page Page

i500, I500A, i500B specifications

The Reliable i500B, i500A, and i500 are a series of high-performance commercial steam boilers that stand out in the industry for their innovative design, efficiency, and reliability. These models are tailored for users who require robust solutions for various steam needs, from industrial applications to food processing and cleaning operations.

The i500B model is known for its powerful output, designed to handle high-demand scenarios. With a high efficiency that reaches up to 90%, the i500B offers optimal fuel consumption while providing superior steam quality. Its advanced burner technology ensures a clean burn, reducing emissions and operational costs. Additionally, the unit features an intelligent control system that simplifies operation, allowing users to optimize performance and maintain precise steam temperature and pressure.

Moving to the i500A, this model is particularly recognized for its compact design without compromising on performance. It is ideal for smaller spaces or applications where footprint is a concern. The i500A boasts features such as a high-capacity feed water system and robust insulation, resulting in reduced heat loss and improved efficiency. This model also integrates a user-friendly control panel that facilitates real-time monitoring and adjustments, making it easier for operators to manage the steam supply.

Lastly, the base i500 model holds its ground as a versatile choice for a variety of applications. It combines reliability with an economical approach to steam generation. The i500 is engineered with durable materials and corrosion-resistant components, ensuring a long service life with minimal maintenance. Its integrated safety features and automatic shut-off systems enhance operational reliability, making it a preferred option for facilities that prioritize safety.

All three models utilize state-of-the-art technologies such as modulating burners, advanced heat recovery systems, and comprehensive diagnostic capabilities. These features contribute to their ability to adapt to fluctuating steam demands efficiently, ensuring consistent performance.

In summary, the Reliable i500B, i500A, and i500 series represent some of the best options available for efficient and reliable steam generation. Their advanced technologies and thoughtful design cater to a wide range of industrial needs, ensuring that users benefit from both performance and economy. Whether in a large manufacturing plant or a smaller workshop, these models provide effective steam solutions that stand the test of time.