GE GNSV75RWW, GNSV70RBL owner manual Contaminant

Page 5

Performance Data Sheet.

 

Organic Chemicals Reduced by Chloroform Surrogate Testing

 

 

Avg.1

Max.

Contaminant

Influent (μg/L)2

Effluent (μg/L)2

Alachlor

50

1.03

Atrazine

100

3.03

Benzene

81

1.03

Carbofuran

190

1.03

Carbon Tetrachloride

78

1.84

Chlorobenzene

77

1.03

Chloropicrin

15

0.24

2,4-D

110

1.74

Dibromochloropropane (DBCP)

52

0.023

o-Dichlorobenzene

80

1.03

p-Dichlorobenzene

40

1.03

1,2-Dichloroethane

88

4.85

1,1-Dichloroethylene

83

1.03

cis-1,2-Dichloroethylene

170

0.53

trans-1,2-Dichloroethylene

86

1.03

1,2-Dichloropropane

80

1.03

cis-1,3-Dichloropropylene

79

1.03

Dinoseb

170

0.24

Endrin

53

0.594

Ethylbenzene

88

1.03

Ethylene Dibromide (EDB)

44

0.023

Haloacetonitriles (HAN):

 

 

Bromochloroacetonitrile

22

0.54

Dibromoacetonitrile

24

0.64

Dichloroacetonitrile

9.6

0.24

Trichloroacetonitrile

15

0.34

1Influent challenge levels are average influent concentrations determined in surrogate qualification testing.

2 μg/L means Micrograms Per Liter.

3 Maximum product water level was not observed but was set at the detection limit of the analysis.

4 Maximum product level is set at a value determined in surrogate qualification testing.

5 Chemical reduction percent and maximum product water level calculated at chloroform 95% breakthrough point as determined in surrogate qualification testing.

6 The surrogate test results for heptachlor Epoxide demonstrated a 98% reduction. These data were used to calculate an upper occurrence concentration, which would produce a maximum product water level at the MCL.

Testing was performed under standard laboratory conditions; actual performance may vary.

NOTE: Substances reduced are not necessarily in your water. Filter must be maintained according to manufacturer’s instructions, including replacement of filter cartridges.

WARNING: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that contain filterable cysts.

5

Image 5
Contents Water Filtration System Safety Instructions System Overview Important Safety Information Water Filtration System Uses the Following Canisters Specifications GuidelinesUsepa Performance Data SheetContaminant Cold Water Supply Fitting Important Installation RecommendationsContents Included With the Product Where codes permit Install the FaucetOpen saddle valve after complete system has been installed If drilling is needed, make a 1″ diameter holePacket Pull tube slightly to make sure it is secureScrew Installation Mounting System InstallationMounting System to Screws Installed in Wall Locate fittings for tubing on bottom of manifold Installing the TubingInstall the Battery Replacing the Filter Canisters Flush ProcedureFQSVF-Replacement filter canister $35-$40 Problem Possible Causes What To Do Before you call for service…General Electric parts catalog Parts ListFor The Period GE Will Replace GE Water Filtration System WarrantyParts and Accessories Schedule ServiceConsumer Support GE Appliances Website Real Life Design Studio