Bacharach Tech 60, 24-9429 quick start Sampling Locations, Water Trap / Filter Maintenance

Page 1

Sampling Locations

Insert the probe in the areas shown in the following illustrations to measure stack temperature, flue-gas O2 content, and flue-gas CO content (Model 60 only).

Atmospheric Burner or

Gravity Vented Forced Air

Hot Water

Tank

80% Eff. Fan Assist or Power Vented Furnace/Boiler

90% Eff.

Condensing

Furnace/Boiler

Water Trap / Filter Maintenance

Drain the water condensate collected in the water trap after every test.

Replace the filter element (P/N 07-1644) when dirty.

Pull apart using a slight twisting motion

Fyrite® Tech 50 & 60

Quick Start Guide 24-9429

Rev. 1 – September 2003

This Guide provides basic information about how to turn ON the analyzer and conduct a combustion efficiency test. Detailed information concerning the analyzer’s operation, set up, and calibration is contained in Instruction 249428.

Turning ON the Analyzer

1.Place the probe tip in the area that contains the burner’s combustion-air source. This step allows the analyzer to measure the combustion-air temperature during the analyzer’s warm-up period.

2.Press analyzer’s I/O button.

3.Wait for the analyzer to complete its 60 second warm-up period.

Performing a Combustion Test

4.Press the or button to select the desired fuel and then press ENTER. The fuel codes are:

F1 = Natural Gas

F3 = LPG

F2 = Oil #2

F4 = Kerosene

Atmospheric or Gravity Vented Boiler

WATER TRAP

FILTER

CHAMBER

CHAMBER

Pry apart filter chamber using a small flat-blade screwdriver inserted into notch

FILTER ELEMENT

“A” When reassembling “B” the trap, make sure

that surfaces “A” and “B” are in contact

Example: “F1” denotes

Natural Gas

Bacharach, Inc.

621 Hunt Valley Circle, New Kensington, PA 15068

Ph: 724-334-5000 • Fax: 724-334-5001 • Toll Free: 800-736-4666 Website: www.bacharach-inc.comE-mail: help@bacharach-inc.com

- 5 -

- 6 -

Printed in U.S.A.

® Registered Trademark

Image 1
Contents Sampling Locations Water Trap / Filter MaintenanceQuick Start Guide Turning on the AnalyzerEnding a Combustion Test Screen Displays Fyrite TechTurning OFF the Analyzer

Tech 50, 24-9429, Tech 60 specifications

Bacharach Tech 50,24-9429, and Tech 60 are two advanced instruments designed to enhance accuracy and efficiency in various industrial applications. These robust tools cater to professionals in sectors such as HVAC, refrigeration, and environmental monitoring, providing them with essential functionality for effective service and maintenance.

One of the standout features of the Bacharach Tech 50 is its portability. Weighing in at a compact size, it allows technicians to easily carry it on-site without sacrificing life performance. The Tech 50 is equipped with high-precision sensors that deliver reliable real-time data on various gas concentrations. This capability is invaluable in ensuring proper ventilation and safety in confined spaces. The intuitive user interface facilitates quick navigation, allowing users to seamlessly switch between measurement modes and access essential data.

On the other hand, Bacharach Tech 60 offers an impressive upgrade in terms of functionalities. It supports multi-gas detection with advanced sensors, providing simultaneous readings for multiple gas types. This capability is particularly beneficial in environments requiring continuous monitoring of air quality. The Tech 60 also features enhanced data logging capabilities, enabling technicians to store and analyze measurement logs for trend analysis and compliance reporting. The instrument's robust design ensures durability, making it suitable for rugged industrial environments.

Both instruments utilize state-of-the-art technology, including advanced microprocessor control and calibration systems, ensuring consistent accuracy and reliability. The user-friendly interface of both devices is designed for quick interactions, facilitating effective and efficient data collections even in high-pressure environments. Both the Tech 50 and Tech 60 support connectivity options such as Bluetooth and USB, enabling seamless data transfer to computers and mobile devices for easy access and further analysis.

In summary, Bacharach Tech 50,24-9429, and Tech 60 stand out in the field of gas detection and environmental monitoring. Their combination of portability, multi-gas capabilities, and robust performance make them essential tools for professionals. As the industry continues to evolve, these instruments represent the higher standards of precision engineering and technological advancement, ensuring that users are equipped to address the needs of modern applications effectively. Investing in Bacharach technology means committing to safety, efficiency, and accuracy in everyday operations.