3M NWS150M Regeneration Instructions, Instructions for Using Regeneration Frequency Schedules

Page 9

SECTION 3: REGENERATION INSTRUCTIONS

INSTRUCTIONS FOR USING REGENERATION FREQUENCY SCHEDULES:

(Time Clock Initiated Models Only)

1)Determine ADJUSTED HARDNESS by adding three (3) times the iron content in parts per million (ppm) to the hardness in grains per gallon (gpg). The resulting number is ADJUSTED HARDNESS.

EXAMPLE: Hardness is 14 gpg and iron is 2 ppm. ADJUSTED HARDNESS is 20 gpg (14 plus 3 times 2).

2)Select REGENERATION FREQUENCY SCHEDULE corresponding to your model. Locate box intersected by NUMBER IN FAMILY and ADJUSTED HARD- NESS (if ADJUSTED HARDNESS is between two numbers in schedule, use higher number). Number in box represents FREQUENCY or NUMBER OF times per 12 DAYS timer should be set to regenerate. Refer to HOW TO SET TIME CLOCK REGENERATION CONTROL to set correct frequency.

EXAMPLE: You have Model NWS100, 4 in family and 20 gpg adjusted hardness. Refer to REGENERATION FREQUENCY SCHEDULE for Model Series 100 and locate box intersected by 4 in family and 20 gpg adjusted hardness. The figure "3" in box indicates a REGENERATION frequency of THREE TIMES PER 12 DAYS (if a "1", "2", "4", etc. were in box, frequencies of once, twice and four times per twelve days, respectively, would be indicated.)

REGENERATION FREQUENCY SCHEDULES

(TIMES PER 12 DAYS)

Model(s) 100

 

 

 

 

 

 

HARDNESS — gpg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Persons In

5

10

15

20

25

30

35

40

45

50

55

60

Family

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

1

1

1

1

1

2

2

2

2

2

2

2

 

 

 

 

 

 

 

 

 

 

 

 

 

2

1

1

2

2

2

3

3

3

4

4

4

6

 

 

 

 

 

 

 

 

 

 

 

 

 

3

1

2

2

3

3

4

4

6

6

6

6

12

 

 

 

 

 

 

 

 

 

 

 

 

 

4

1

2

3

3

4

6

6

6

12

12

12

12

 

 

 

 

 

 

 

 

 

 

 

 

 

5

1

2

3

4

6

6

12

12

12

12

12

12

 

 

 

 

 

 

 

 

 

 

 

 

 

6

2

3

4

6

6

12

12

12

12

12

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

2

3

4

6

6

12

12

12

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

2

3

6

6

12

12

12

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model(s) 150

 

 

 

 

 

 

 

HARDNESS — gpg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Persons In

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75

Family

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

1

1

1

1

1

1

1

1

1

2

2

2

2

2

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

1

1

1

1

2

2

2

2

3

3

3

3

3

4

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

1

1

1

2

2

3

3

3

4

4

4

6

6

6

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

1

1

2

2

3

3

4

4

6

6

6

6

6

12

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

1

2

2

3

3

4

4

6

6

6

12

12

12

12

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

1

2

3

3

4

6

6

6

12

12

12

12

12

12

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

1

2

3

4

4

6

6

12

12

12

12

12

12

12

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

1

2

3

4

6

6

12

12

12

12

12

12

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

1

3

4

6

6

12

12

12

12

12

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

2

3

4

6

6

12

12

12

12

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-1

Image 9
Contents Installation and Operating Instructions Explanation of Signal Word Consequences Table of Contents Check Your Pumping Rate and Water Pressure Important Note Installation OUT Flow Line with Valve Drain Line Step Instructions for Using Regeneration Frequency Schedules Regeneration InstructionsRegeneration Frequency Schedules Times PER 12 Days HOW to SET Days on Which Water Softener is to Regenerate HOW to SET the Time of DAYHOW to Manually Regenerate Your Water Softener AT ANY Time Optional Programming Procedure Bottom of brine tank Service InstructionsSpecification and Operating Data Parts Components Parts List TWO Tank Models NS & NSM SeriesControl Valve -12 DAY Timer Parts List 12 DAY Timer Control Valve Meter Initiated Parts List Meter Timer Periodically Check Time of DAY Setting Brine Tank CLEAN-OUTType of Salt to USE Preventing IRON-FOULING of Mineral BEDLimited Warranty

NWS100M, NWS150, NWS150M, NWS200M, NWS200 specifications

3M is a leading brand in personal protective equipment, particularly known for its advanced respiratory solutions. Among its range, the 3M NWS series, which includes models NWS100, NWS200, NWS200M, NWS150M, and NWS150, stands out for its innovative features and user-friendly designs. These respiratory protection devices cater to various industrial and healthcare applications, providing reliable performance in demanding environments.

The 3M NWS100 model is designed for basic respiratory protection, featuring a lightweight and comfortable design that encourages prolonged use. Its simple structure allows for easy donning and doffing, making it an ideal choice for facilities where quick access to respiratory protection is essential. Equipped with a high-efficiency filter, the NWS100 effectively captures airborne particles, ensuring the user's safety against dust and other hazardous materials.

In contrast, the 3M NWS200 series incorporates additional features for enhanced protection. This model offers a dual-filter system, which significantly improves the user’s respiratory safety by providing superior filtration against various contaminants. The NWS200 is also equipped with an adjustable headband that ensures a snug fit, critical for maximizing both safety and comfort during wear.

The 3M NWS200M model takes this a step further with its ergonomic design tailored for use in higher-risk environments, where both comfort and efficacy are paramount. This variant features a full-face shield offering additional facial coverage, making it suitable for medical facilities where exposure to infectious agents is a concern. Furthermore, the NWS200M utilizes 3M’s proprietary filtration technology, boasting a higher capture efficiency for fine particles during aerosol-generating procedures.

The 3M NWS150M and NWS150 models share similar characteristics but are designed with slightly different user needs in mind. The NWS150M incorporates a moisture-wicking layer that enhances breathability, which is advantageous during extended wear. On the other hand, the NWS150, while still providing essential protection against particulate hazards, emphasizes a more economical option without sacrificing performance.

Together, the NWS series exemplifies 3M’s commitment to innovation in respiratory protection, ensuring that workers in various industries can access reliable and effective solutions tailored to their specific environments. Each model combines comfort, advanced filtration technology, and user-centric design to provide peace of mind in challenging working conditions. Whether in industrial settings or healthcare applications, the 3M NWS series offers robust solutions that prioritize the safety of users.