3M NWS100M, NWS200M, NWS150M manual Check Your Pumping Rate and Water Pressure

Page 4

Check Your Pumping Rate and Water Pressure:

Two water system conditions must be checked carefully to avoid unsatisfactory operation or equipment damage:

1)MINIMUM water pressure required at the water softener inlet is 20 psi (138 kPa). IF WATER PRESSURE IS OVER 80 psi (552 kPa), A PRESSURE RE-

DUCING VALVE MUST BE INSTALLED IN THE WATER SUPPLY LINE AHEAD OF THE WATER SOFTENER.

CAUTION

To reduce the risk associated with property damage due to water leakage:

Do not install if water pressure exceeds 100 psi. If your water pressure exceeds 80 psi (552 kPa), you must install a pressure limiting valve. Contact a plumb- ing professional if you are uncertain how to check your water pressure.

NOTE: If you have a municipal or a community water supply and daytime water pressure is 85 psi or more, nighttime pressure may exceed 100 psi. Call your local water department or plant operator to obtain pressure readings. If you have a private well, the gauge on the pressure tank will indicate the high and low system pressure. Record your water pressure data below:

Water Pressure:

Low

 

psi

High

 

psi

CAUTION

To reduce the risk associated with property damage due to water leakage:

• Do not install system where water lines could be subjected to vacuum conditions without appropriate measures for vacuum prevention.

The installer should take appropriate measures if there is the possibility a vacuum may occur. This would include the installation of an appropriate device in the supply line to the system, i.e., a vacuum breaker or backflow prevention device. Vacuum damage voids the factory warranty.

2)The pumping rate of your well must be sufficient for satisfactory operation and BACKWASHING of the water softener. (See SPECIFICATIONS AND OPERATING DATA, Section 6)

Locate Water Conditioning Equipment Correctly:

Select the location of your water softener with care. Various conditions which contribute to proper location are as follows:

1)Locate as close as possible to water supply source.

2)Locate as close as possible to a drain.

3)Locate in correct relationship to other water conditioning equipment (Figure 1, page 2-1).

4)Locate the softener in the supply line BEFORE the water heater. Temperatures above 110°F (43.3°C) will damage the softener and void the factory warranty.

5)DO NOT install the softener in a location where freezing temperatures occur. Freezing may cause permanent damage and will also void the factory warranty.

6)Allow sufficient space around the installation for easy servicing.

7)Provide a non-switched 110V, 60Hz (220V, 50Hz for specified systems) power source for the control valve.

WARNING

To reduce the risk associated with ingestion of contaminants:

• Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

CAUTION

To reduce the risk associated with property damage due to water leakage:

Protect from freezing, relieve pressure and drain system when temperatures are expected to drop below 33°F (0.6°C).

Do not install on hot water supply lines. The maximum operating water temperature of this filter system is 110°F (43.3°C).

1-2

Image 4
Contents Installation and Operating Instructions Explanation of Signal Word Consequences Table of Contents Check Your Pumping Rate and Water Pressure Important Note Installation OUT Flow Line with Valve Drain Line Step Regeneration Instructions Instructions for Using Regeneration Frequency SchedulesRegeneration Frequency Schedules Times PER 12 Days HOW to SET the Time of DAY HOW to SET Days on Which Water Softener is to RegenerateHOW to Manually Regenerate Your Water Softener AT ANY Time Optional Programming Procedure Service Instructions Bottom of brine tankSpecification and Operating Data Components Parts List TWO Tank Models NS & NSM Series PartsControl Valve -12 DAY Timer Parts List 12 DAY Timer Control Valve Meter Initiated Parts List Meter Timer Brine Tank CLEAN-OUT Periodically Check Time of DAY SettingType of Salt to USE Preventing IRON-FOULING of Mineral BEDLimited Warranty

NWS100M, NWS150, NWS150M, NWS200M, NWS200 specifications

3M is a leading brand in personal protective equipment, particularly known for its advanced respiratory solutions. Among its range, the 3M NWS series, which includes models NWS100, NWS200, NWS200M, NWS150M, and NWS150, stands out for its innovative features and user-friendly designs. These respiratory protection devices cater to various industrial and healthcare applications, providing reliable performance in demanding environments.

The 3M NWS100 model is designed for basic respiratory protection, featuring a lightweight and comfortable design that encourages prolonged use. Its simple structure allows for easy donning and doffing, making it an ideal choice for facilities where quick access to respiratory protection is essential. Equipped with a high-efficiency filter, the NWS100 effectively captures airborne particles, ensuring the user's safety against dust and other hazardous materials.

In contrast, the 3M NWS200 series incorporates additional features for enhanced protection. This model offers a dual-filter system, which significantly improves the user’s respiratory safety by providing superior filtration against various contaminants. The NWS200 is also equipped with an adjustable headband that ensures a snug fit, critical for maximizing both safety and comfort during wear.

The 3M NWS200M model takes this a step further with its ergonomic design tailored for use in higher-risk environments, where both comfort and efficacy are paramount. This variant features a full-face shield offering additional facial coverage, making it suitable for medical facilities where exposure to infectious agents is a concern. Furthermore, the NWS200M utilizes 3M’s proprietary filtration technology, boasting a higher capture efficiency for fine particles during aerosol-generating procedures.

The 3M NWS150M and NWS150 models share similar characteristics but are designed with slightly different user needs in mind. The NWS150M incorporates a moisture-wicking layer that enhances breathability, which is advantageous during extended wear. On the other hand, the NWS150, while still providing essential protection against particulate hazards, emphasizes a more economical option without sacrificing performance.

Together, the NWS series exemplifies 3M’s commitment to innovation in respiratory protection, ensuring that workers in various industries can access reliable and effective solutions tailored to their specific environments. Each model combines comfort, advanced filtration technology, and user-centric design to provide peace of mind in challenging working conditions. Whether in industrial settings or healthcare applications, the 3M NWS series offers robust solutions that prioritize the safety of users.