American Standard 2791, 2457, 2459, 2455 Care and Cleaning, Adjustments, Troubleshooting, Diagram

Page 3

10

TOP

ARM

REFILL

NIPPLE

 

 

TUBE

 

 

 

TANK

CRITICAL LEVEL

LEVER

MARK ("C.L.")

 

 

MUST BE

 

 

1" ABOVE

 

 

OVERFLOW PIPE

FLOAT

 

 

 

 

CUP

 

FILL

 

 

VALVE

 

 

FLUSH

VALVE

VALVE

 

BODY

WATER LEVEL

 

ADJUSTMENT

 

ROD

ADJUSTABLE

HEIGHT

FLAPPER

SHANK

WASHER

LOCK NUT

THREADED

 

SHANK

CONE WASHER

 

 

PARTS FOR WATER

COUPLING NUT

CONNECTION

(SEE STEP 9)

(HAND TIGHT ONLY)

Diagram 1

 

ADJUSTMENTS

a.Adjust water level. Water level should be adjusted to level indicated on tank by adjusting float cup.

See Step 11 for water level adjustment method

b.If bowl fails to siphon, an adjustment may be required with the lift chain. Simply remove the bead chain from the retainment clip and take up slack on the chain, and reinsert on lift rod. Make sure the chain is not too taught.

11

Turn on water supply. Submerge the FLOAT CUP under the water for 30 seconds. Adjust the water to desired level by turning WATER LEVEL ADJUSTMENT ROD and moving FLOAT CUP up or down.

12CARE AND CLEANING

When cleaning your toilet, wash it with mild, soapy water, rinse thoroughly with clear water and dry with a soft cloth. Avoid detergents, disinfectants, or cleaning products in aerosol cans. NEVER use abrasive scouring powders or abrasive pads on your toilet seat. Some bathroom chemicals and cosmetics may damage the seat's finish.

!WARNING: Do not use in-tank cleaners. Products containing chlorine (calcium hypochlorite) can seriously damage fittings in the tank. This damage can cause leakage and property damage.

American Standard shall not be responsible or liable for any tank fitting damage caused by the use of cleaners containing chlorine (calcium hypochlorite).

13

LIFT ARM

FIRST

IMPORTANT: Always clear sand and rust from system.

Make sure water supply is off. Remove valve TOP by lifting arm and rotating top and arm 1/8 turn counterclockwise, pressing down slightly on cap.

While holding a container over the uncapped VALVE to prevent splashing, turn water supply on and off a few times. Leave water supply off.

Replace TOP by engaging lugs and rotating 1/8 turn clockwise. MAKE CERTAIN TIP IS TURNED TO THE LOCKED POSITION. VALVE MAY NOT TURN ON IF TOP IS NOT FULLY TURNED TO THE LOCKED POSITION.

TROUBLESHOOTING

IF FILL VALVE SHUTS OFF BUT CONTINUES TO LEAK SLOWLY, repeat Step 13.

IF FILL VALVE TURNS OFF AND ON DURING PERIODS OF NON-USE, it is a signal you are wasting water because:

The end of the refill tube is inserted into overflow pipe, below water level in tank. Attach refill tube to overflow pipe using "S" clip provided.

The flush valve is leaking because it's worn, dirty or

misaligned with tank ball or flapper (replace with a new flapper).

IF FILL VALVE WON'T TURN ON OR SHUT OFF or REFILL OF TANK WATER IS SLOW after valve has been in use for some

time, Fluidmaster Model 242 Replacement Seal may be needed.

Go to our website at www.fluidmaster.com for more solutions to toilet problems.

For troubleshooting information please contact:

30800 Rancho Viejo Road

San Juan Capistrano, CA 92675

Always use quality Fluidmaster repair parts when maintaining your Fluidmaster products. Fluidmaster shall not be responsible or liable for any damages caused by products used with Fluidmaster valves that were not manufactured by Fluidmaster, Inc.

(949)728-2000 (800) 631-2011 www.fluidmaster.com

© 2001 Fluidmaster, Inc.

® Registered trademark of Fluidmaster, Inc.

- 3 -

7301102-100 Rev. K

Image 3
Contents ROUGHING-IN Dimensions Install Closet BoltsInstall WAX Seal Position Toilet on Flange Plastic Supply Line Install ToiletInstall Tank Cone Washer withDiagram Care and CleaningAdjustments TroubleshootingRepair Parts List Problem Possible Cause Corrective ActionUnited States
Related manuals
Manual 4 pages 34.23 Kb