Mitsubishi Electronics PL42FK21, PL36FK31, PL30FK21, PL18FK21, PL12FK1 OC194-24, DRY Operation

Page 24

DRY OPERATION

DRY

 

 

 

 

operation

 

NO

Initial dry

 

 

operation

 

 

YES

w8

Vane

Vane initial setting

setting notch

 

YES

Room temperature is

w12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

64-F or lower

 

 

 

 

 

 

NO

 

 

 

 

 

 

During

 

NO

 

 

 

 

compressor ON

 

 

 

 

 

 

YES

 

 

 

 

 

 

3-minute

 

NO

 

3-minute

YES

 

compressor

 

 

 

time delay

 

 

operation

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

NO

 

NO

Compressor &

w9

 

YES

Compressor &

w9

 

 

 

 

thermostat ON

 

 

 

thermostat

 

 

 

 

 

 

ON

 

 

YES

 

 

 

NO

 

 

Compressor ON

 

NO

 

10-minute

NO

 

 

 

 

compressor

 

 

time completes

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

YES

 

 

 

YES

 

 

 

 

 

 

 

w13

 

10-minute compressor

 

 

Compressor ON

 

 

OFF timer start

 

 

 

time set

 

 

Compressor OFF

 

 

Compressor ON

 

 

 

w14

 

 

 

w14

 

Fan STOP

 

 

 

Fan speed LOW

 

 

1

 

 

 

 

 

w8—9 Refer to page OC194-23.

w12 When room temperature is 64°F or below, the compressor cannot operate.

When room temperature rises over 64°F the compressor starts after a 3-minute time delay. w13 Compressor ON time is decided by room temperature. Refer to page OC194-29.

w14 In dry operation, compressor ON makes the fan speed LOW. Also, when the compressor OFF and the pipe temperature is 79°F or less, the fan stops, or when the compressor OFF and the pipe temperature is below 43°F the fan speed changes to LOW mode.

It is not possible to set the fan speed with the remote controller

OC194-24

Image 24
Contents Contents OC194-1Technical Change OC194-2Features OC194-3Models Cooling capacity Advanced Microprocessor ControlRemote controller operation buttons Part Names and FunctionsOC194-4 Remote controller display OC194-5Specifications OC194-6Models PL12FK1, PL18/24FK21 OC194-7 Models PL30FK21, PL36FK31, PL42FK21Data OC194-8Models PL12FK1, PL18/24/30FK21, PL36FK31, PL42FK21 Performance DataOC194-9 Performance CurveOC194-10 PL24FK2 1 Cooling Capacity PL30FK2 1 Cooling CapacityOC194-11 Condensing Pressure and Suction PressureOC194-12 OC194-13 OC194-14 Standard Operation DataOperating Range OC194-15 Noise Criterion CurvesPL12FK PL18FK21OC194-16 PL24FK2PL42FK2 PL36FK31Outlines and Dimensions OC194-17Indoor Unit PL12FK1/ 18/24FK21OC194-18 PL30FK21/ 36FK31/ 42FK21Refrigerant System Diagram OC194-19PL12FK1 Wiring Diagram Models PL12FK1 PL18FK21 PL24FK21 Wiring DiagramOC194-20 Models PL30FK21 PL36FK31 PL42FK21 Wiring Diagram OC194-21Operation FLOW-CHART OC194-22Main Operation OC194-23 Cooling OperationOC194-24 DRY OperationIndoor unit Orders Remote controller LCD indicator Microprocessor ControlOC194-25 Outline of Microprocessor ControlHow to operate OC194-26Indoor Unit Control Compressor controlOC194-27 OC194-28 Detecting abnormalities in the outdoor unitDrain pump control Drain sensorDRY operation time chart How to operate OC194-29DRY operation OC194-30 OC194-31 SwingCOOL/DRY operation Auto returnTimer operation Timer functionOC194-32 Test run Before test runOC194-33 Emergency operationBefore emergency operation DIP Switch Functions On remote controller boardOC194-34 On indoor controller boardOC194-35 Indoor FAN ControlTroubleshooting OC194-36Troubles in Test RUN When malfunction occurs during operation Check modeFor group control using one remote controller OC194-37OC194-38 Wrong Wiring on Site OC194-39OC194-40 Other Troubles and CausesOC194-41 Vane motorOC194-42 12 4-WAY AIR Flow System OC194-43Internal surface view of the grill OC194-44 Regular ceiling heightRelatively high ceiling High ceiling17-11/16 Examples of application Precautions OC194-45OC194-46 OC194-47 Duct PressureFresh-Air P-V curve Ambient air flow CFMBranch Duct installation at site OC194-48Direction discharge 11-13/16O4 directions Direction discharge 17-11/16O2 directionsOC194-49 PL30FK21/ 36FK31 PLH42FK21System Control OC194-50Variety of System Control Functions PAC-SA89TA-EGroup Control by a Single Remote Controller OC194-51ALL OFF SW2 Control Using TWO Remote Controllers Remote ON-OFF and Individual Remote ControlsHow to set SW17-7 See Figure Remote controller LCD indicationIndividual Control by Grouping the Remote Controllers Basic wiringSwitch function of remote ON-OFF switch OC194-53Multiple Remote Control Display Timer Operation or the Operation by AN External SignalOC194-54 Auto Restart FunctionDisassembly Procedure Operating Procedure PHOTOS&ILLUSTRATIONSOC194-55 Indoor unit PL24FK21OC194-56 Parts List OC194-57PL12FK, PL18FK2, PL24FK2 Panel Parts PL12FK1, PL18FK21, PL24FK21OC194-58 PL12FK, PL18FK2, PL24FK2 Functional PartsOC194-59 OC194-60 PL30FK2, PL36FK3, PL42FK2 Functional PartsPL30FK21, PL36FK31, PL42FK21 OC194-61 OC194-62 PL30FK2, PL36FK3, PL42FK2 Panel PartsT7W 413 R01 K21 691Timer Optional PartsOC194-63 PAC-SC32PTA Weekly Timer Setting Display OC194-64Names and functions Current Time DisplayTimer Adapter Multiple Remote Controller AdapterOC194-65 PAC-SA89TA-E ORN BRN REDDistributed in Dec . No.OC256 Specifications are subject to change without notice

PL18FK21, PL30FK21, PL12FK1, PL36FK31, PL24FK21 specifications

Mitsubishi Electronics has long been recognized for its commitment to quality and innovation in the field of air conditioning systems. Among its impressive lineup, the models PL42FK21, PL24FK21, PL36FK31, PL12FK1, and PL30FK21 stand out for their advanced features, efficiency, and user-friendly designs.

The PL42FK21 is designed to deliver superior cooling and heating performance, making it suitable for larger spaces. With its high energy efficiency rating, it minimizes energy consumption while providing optimal comfort. This model is equipped with advanced inverter technology that regulates the compressor speed, ensuring the desired temperature is maintained without unnecessary fluctuations in power usage.

Next, the PL24FK21 offers similar efficiencies while accommodating medium-sized spaces. This model incorporates a streamlined design that blends with any interior, while its quiet operation ensures that it does not disrupt daily activities. Moreover, the model features a programmable timer and remote control, enhancing user convenience and comfort.

The PL36FK31 is another model that brings forth powerful performance, ideal for commercial applications or larger residential installations. It boasts superior airflow distribution, ensuring even cooling or heating throughout the desired area. The addition of a high-performance filter system helps to purify the air, making it a healthy option for families and workplaces alike.

For those seeking a compact solution, the PL12FK1 is a standout choice. This model excels in efficiency while maintaining a small footprint, making it perfect for apartments or smaller rooms. With its energy-saving capabilities and modern design, this unit combines functionality and style seamlessly.

Finally, the PL30FK21 balances performance with affordability. This model comes with a host of features, including an eco-friendly refrigerant that minimizes environmental impact. It also incorporates smart controls that enable users to manage their settings via mobile apps, adding a level of modern convenience that many consumers desire.

Each of these Mitsubishi models is built with durability in mind, ensuring they can withstand the rigors of daily use. Additionally, Mitsubishi Electronics provides exceptional customer support and warranty options, reflecting their commitment to customer satisfaction.

In summary, the PL42FK21, PL24FK21, PL36FK31, PL12FK1, and PL30FK21 from Mitsubishi Electronics exemplify the brand's dedication to innovation, efficiency, and user-friendliness in air conditioning technology. These models cater to a variety of spaces and user needs, making them a reliable choice for both residential and commercial applications.