2-4 TIMER operation

WIRED REMOTE CONTROLLER

 

 

SWING

 

TIMER OFF TIMER￿

CLOCK AUTO AUTO￿

FAN￿

 

CHECK SET TEMP.

START STOP

FILTER

SPEED

 

 

AUTO￿

CHECK MODE

 

 

RETURN

TEST RUN

<Timer setting example>

AUTO￿

STOP

<Timer function>

AUTO STOP ··········The air conditioner stops after the set time lapses. AUTO START ········The air conditioner starts after the set time lapses. AUTO OFF ············Timer is not active.

<How to operate>

1.Press POWER ON/OFF button.

2.Press “TIMER ON/OFF” button to select AUTO STOP or AUTO START.

3.Press “CLOCK/TIMER” button to set desired time.

Time setting is in 1 hour units for up to 24 hours.

Each time TIMER SET button is pressed, set time increases by 1 hour. When TIMER SET button is pressed and held, the set time increases by 1 hour every 0.5 seconds.

4. To cancel the timer operation, press POWER ON/OFF button.

This setting will stop the operation in 8hours.

With the lapse of time, time display changes in 1hour units, showing remaining time.

2-5 Test run <Before test run>

After installing, wiring, and piping the indoor and outdoor units, check for refrigerant leakage, looseness in power supply or control wiring, and mistaken polarity.

Use a 500-volt measure to check the resistance between the power supply terminal block and ground to make sure that it is

at least 1.0M'.

Attention:

Do not use the air conditioner if resistance is less than 1.0M'.

COOL

 

 

SWING

F

 

 

 

 

 

 

 

 

FAN￿

 

 

 

 

 

SPEED

AUTO￿

 

 

 

 

 

RETURN

 

MODE

TIMER ON/OFF CLOCK/TIMER

FAN SPEED

AIR DISCHARGE FILTER

 

 

 

 

AIR SWEEP

CHECK

 

SET TEMP.

TIMER SET

 

 

TEST RUN

REMOTE CONTROLLER￿

 

 

 

 

 

PAR-JH240KUS

 

 

 

 

 

 

 

TEST RUN button

Displayed during test run

<How to operate>

1.Turn ON main breaker.

2.Press TEST RUN button twice. “TEST RUN” is displayed on remote controller.

3.Select “COOL” with MODE button to check that cool air is beginning discharged.

Select “HEAT” with MODE button to check that warm air is beginning discharged.(after a while)

4.Select LOW/HIGH with FAN SPEED button to check that the fan speed changes properly.

5.Press AIR DISCHARGE button to check auto vane operation.

6.Check outdoor fan operation.

7.Check compressor operation referring to the indoor coil temperature code displayed on the remote controller.

8.After checking, press the ON/OFF button.

·The test run works for 2 hours and stops automatically.

To cancel the test run, press ON / OFF button or TIMER ON / OFF button.

OC194-32

Image 32
Contents Contents OC194-1Technical Change OC194-2Features OC194-3Models Cooling capacity Advanced Microprocessor ControlOC194-4 Remote controller operation buttonsPart Names and Functions Remote controller display OC194-5Models PL12FK1, PL18/24FK21 SpecificationsOC194-6 OC194-7 Models PL30FK21, PL36FK31, PL42FK21Data OC194-8Models PL12FK1, PL18/24/30FK21, PL36FK31, PL42FK21 Performance DataOC194-9 Performance CurveOC194-10 PL24FK2 1 Cooling Capacity PL30FK2 1 Cooling CapacityOC194-11 Condensing Pressure and Suction PressureOC194-12 OC194-13 Operating Range OC194-14Standard Operation Data OC194-15 Noise Criterion CurvesPL12FK PL18FK21OC194-16 PL24FK2PL42FK2 PL36FK31Outlines and Dimensions OC194-17Indoor Unit PL12FK1/ 18/24FK21OC194-18 PL30FK21/ 36FK31/ 42FK21PL12FK1 Refrigerant System DiagramOC194-19 OC194-20 Wiring DiagramModels PL12FK1 PL18FK21 PL24FK21 Wiring Diagram Models PL30FK21 PL36FK31 PL42FK21 Wiring Diagram OC194-21Main Operation Operation FLOW-CHARTOC194-22 OC194-23 Cooling OperationOC194-24 DRY OperationIndoor unit Orders Remote controller LCD indicator Microprocessor ControlOC194-25 Outline of Microprocessor ControlHow to operate OC194-26Indoor Unit Control Compressor controlOC194-27 OC194-28 Detecting abnormalities in the outdoor unitDrain pump control Drain sensorDRY operation DRY operation time chart How to operateOC194-29 OC194-30 OC194-31 SwingCOOL/DRY operation Auto returnTimer operation Timer functionOC194-32 Test run Before test runBefore emergency operation OC194-33Emergency operation DIP Switch Functions On remote controller boardOC194-34 On indoor controller boardOC194-35 Indoor FAN ControlTroubles in Test RUN TroubleshootingOC194-36 When malfunction occurs during operation Check modeFor group control using one remote controller OC194-37OC194-38 Wrong Wiring on Site OC194-39OC194-40 Other Troubles and CausesOC194-41 Vane motorOC194-42 Internal surface view of the grill 12 4-WAY AIR Flow SystemOC194-43 OC194-44 Regular ceiling heightRelatively high ceiling High ceiling17-11/16 Examples of application Precautions OC194-45OC194-46 OC194-47 Duct PressureFresh-Air P-V curve Ambient air flow CFMBranch Duct installation at site OC194-48Direction discharge 11-13/16O4 directions Direction discharge 17-11/16O2 directionsOC194-49 PL30FK21/ 36FK31 PLH42FK21System Control OC194-50Variety of System Control Functions PAC-SA89TA-EALL OFF SW2 Group Control by a Single Remote ControllerOC194-51 Control Using TWO Remote Controllers Remote ON-OFF and Individual Remote ControlsHow to set SW17-7 See Figure Remote controller LCD indicationIndividual Control by Grouping the Remote Controllers Basic wiringSwitch function of remote ON-OFF switch OC194-53Multiple Remote Control Display Timer Operation or the Operation by AN External SignalOC194-54 Auto Restart FunctionDisassembly Procedure Operating Procedure PHOTOS&ILLUSTRATIONSOC194-55 Indoor unit PL24FK21OC194-56 Parts List OC194-57PL12FK, PL18FK2, PL24FK2 Panel Parts PL12FK1, PL18FK21, PL24FK21OC194-58 PL12FK, PL18FK2, PL24FK2 Functional PartsOC194-59 PL30FK21, PL36FK31, PL42FK21 OC194-60PL30FK2, PL36FK3, PL42FK2 Functional Parts OC194-61 OC194-62 PL30FK2, PL36FK3, PL42FK2 Panel PartsT7W 413 R01 K21 691OC194-63 TimerOptional Parts PAC-SC32PTA Weekly Timer Setting Display OC194-64Names and functions Current Time DisplayTimer Adapter Multiple Remote Controller AdapterOC194-65 PAC-SA89TA-E ORN BRN REDDistributed in Dec . No.OC256 Specifications are subject to change without notice

PL18FK21, PL30FK21, PL12FK1, PL36FK31, PL24FK21 specifications

Mitsubishi Electronics has long been recognized for its commitment to quality and innovation in the field of air conditioning systems. Among its impressive lineup, the models PL42FK21, PL24FK21, PL36FK31, PL12FK1, and PL30FK21 stand out for their advanced features, efficiency, and user-friendly designs.

The PL42FK21 is designed to deliver superior cooling and heating performance, making it suitable for larger spaces. With its high energy efficiency rating, it minimizes energy consumption while providing optimal comfort. This model is equipped with advanced inverter technology that regulates the compressor speed, ensuring the desired temperature is maintained without unnecessary fluctuations in power usage.

Next, the PL24FK21 offers similar efficiencies while accommodating medium-sized spaces. This model incorporates a streamlined design that blends with any interior, while its quiet operation ensures that it does not disrupt daily activities. Moreover, the model features a programmable timer and remote control, enhancing user convenience and comfort.

The PL36FK31 is another model that brings forth powerful performance, ideal for commercial applications or larger residential installations. It boasts superior airflow distribution, ensuring even cooling or heating throughout the desired area. The addition of a high-performance filter system helps to purify the air, making it a healthy option for families and workplaces alike.

For those seeking a compact solution, the PL12FK1 is a standout choice. This model excels in efficiency while maintaining a small footprint, making it perfect for apartments or smaller rooms. With its energy-saving capabilities and modern design, this unit combines functionality and style seamlessly.

Finally, the PL30FK21 balances performance with affordability. This model comes with a host of features, including an eco-friendly refrigerant that minimizes environmental impact. It also incorporates smart controls that enable users to manage their settings via mobile apps, adding a level of modern convenience that many consumers desire.

Each of these Mitsubishi models is built with durability in mind, ensuring they can withstand the rigors of daily use. Additionally, Mitsubishi Electronics provides exceptional customer support and warranty options, reflecting their commitment to customer satisfaction.

In summary, the PL42FK21, PL24FK21, PL36FK31, PL12FK1, and PL30FK21 from Mitsubishi Electronics exemplify the brand's dedication to innovation, efficiency, and user-friendliness in air conditioning technology. These models cater to a variety of spaces and user needs, making them a reliable choice for both residential and commercial applications.